Electrical installation
4.4 Connections
Establishing the connection
Take care not to cut yourself on the sharp edges inside the cabinet when connecting the
auxiliary power supply system.
1. Disconnect the cabinet from the power supply.
2. Observe the "five safety rules".
3. Fasten the cables to terminal block -X101 of the next module:
Note
Establishing the connection for Basic Line Modules
Basic Line Modules do not contain auxiliary power modules. The 24 V DC voltage supply is
provided by connecting the 2-phase cable included in the Basic Line Module to the auxiliary
power module of the adjacent cabinet unit.
When establishing connections to the auxiliary power supply system, you must ensure that
you do not mix up the power supplies. Errors or carelessness can result in serious injury or
damage to the components or system.
4.4.4.4

Connecting to the infeed

Description
The voltages provided on the auxiliary power supply system must be produced by an
auxiliary power supply (e.g. by an Auxiliary Power Supply Module or by Option K76 "Auxiliary
voltage generating unit in the Line Connection Module").
If an Auxiliary Power Supply Module is not available to supply power to the auxiliary power
supply system or if the Auxiliary Power Supply Module and the Cabinet Modules to be
supplied are installed in different parts of the cabinet line-up, an auxiliary power module in
the Line Connection Module can be used to feed power to the auxiliary power supply
system. Further alternatives for feeding power are in the first or last auxiliary power module
of the drive line-up. The maximum current-carrying capacity of the auxiliary power supply
system is 80 A. In the case of the external power supply, this must be fuse protected on the
line side.
74
CAUTION
4-phase cable (1-2): for line voltage to terminals 1 and 2
4-phase cable (3-4): for 230 V AC to terminals 3 and 4