Yamaha CL1 Reference Manual page 224

Hide thumbs Also See for CL1:
Table of Contents

Advertisement

3
GPI OUT SETUP popup button
Press this button to open the GPI OUT SETUP popup window.
The button shows the name of the currently selected function or parameter.
4
TEST button
While this is on, the corresponding GPI OUT port will be active and will output a control signal.
5.
Specify the POLARITY MODE for each port.
For each port, select either low-active or high-active as appropriate for the specifications of the
external device you're using.
6.
To assign a function or parameter, press the GPI OUT SETUP popup button.
You can assign the following functions.
Function
Parameter
NO ASSIGN
---
CUE ON
DCA ONLY
CUE ACTIVE
INPUT ONLY
OUTPUT ONLY
GPI IN ACTIVE IND. PORT 1–PORT 5
POWER ON
---
USER DEF.
USER DEFINED KEY 1–
KEY ACTIVE IND.
USER DEFINED KEY 16
CL console operation
No assignment
Turn on the [CUE] key of the selected channel
Turn on the DCA [CUE] key
Turn on the [CUE] key of an input channel
Turn on the [CUE] key of an output channel
The function assigned to GPI IN port 1–5
becomes active
The power of the CL series console is turned on
The function assigned to the USER DEFINED
key becomes active
7.
In each field, select the desired function or parameter.
8.
When you have finished making settings, press the OK button.
9.
Repeat steps 5 through 8 to specify functions and parameters for other ports.
Using FADER START
Make FADER START settings if you want a device connected to a GPI OUT port to operate in tandem
with fader operations.
1.
Connect an external device to the CL series console's GPI connector.
2.
In the function access area, press the SETUP button to access the SETUP screen.
3.
Press the MIDI/GPI button.
The MIDI/GPI screen will appear.
224
Other functions
Reference Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl3Cl5

Table of Contents