ACS 800-01 type
400 V units
-0003-3
-0004-3
-0005-3
-0006-3
-0009-3
-0011-3
-0016-3
-0020-3
-0025-3
-0030-3
-0040-3
-0050-3
-0060-3
-0070-3
-0100-3
-0120-3
500 V units
-0004-5
-0005-5
-0006-5
-0009-5
-0011-5
-0016-5
-0020-5
-0025-5
-0030-5
-0040-5
-0050-5
-0060-5
-0070-5
-0100-5
-0120-5
-0140-5
690 V units
-0011-7
-0016-7
-0020-7
-0025-7
-0030-7
-0040-7
-0050-7
-0060-7
-0070-7
-0100-7
-0120-7
P
The drive and the chopper will withstand this continuous braking power. The braking is considered continuous if the braking time
brcont
exceeds 30 s.
Note: The braking energy transmitted to the specified resistor(s) in 400 seconds may not exceed E
R
Resistance value for the listed resistor assembly. Note: This is also the minimum allowed resistance for the brake resistor.
E
Short energy pulse that the resistor assembly withstands every 400 seconds. This energy will heat the resistor element from 40 °C
R
(104 °F) to the maximum allowable temperature.
P
Continuous power (heat) dissipation of the resistor when placed correctly. Energy E
Rcont
All braking resistors must be installed outside the converter module. The SACE braking resistors are built in an IP 21 metal housing. The
SAFUR braking resistors are built in an IP 00 metal frame.
Braking power of
Brake resistor(s)
the chopper and the
drive
P
Type
brcont
(kW)
1.1
SACE08RE44
1.5
SACE08RE44
2.2
SACE08RE44
3.0
SACE08RE44
4.0
SACE08RE44
5.5
SACE15RE22
7.5
SACE15RE22
11
SACE15RE22
23
SACE15RE13
28
SACE15RE13
33
SAFUR90F575
45
SAFUR90F575
56
SAFUR90F575
68
SAFUR80F500
83
SAFUR125F500
113
SAFUR125F500
1.5
SACE08RE44
2.2
SACE08RE44
3.0
SACE08RE44
4.0
SACE08RE44
5.5
SACE08RE44
7.5
SACE15RE22
11
SACE15RE22
15
SACE15RE22
28
SACE15RE13
33
SACE15RE13
45
SAFUR90F575
56
SAFUR90F575
68
SAFUR90F575
83
SAFUR125F500
113
SAFUR125F500
135
SAFUR125F500
5.5
SACE08RE44
7.5
SACE08RE44
11
SACE08RE44
15
SACE08RE44
18.5
SACE15RE22
22
SACE15RE22
30
SAFUR90F575
37
SAFUR90F575
45
SAFUR90F575
55
SAFUR80F500
75
SAFUR80F500
R
E
R
(ohm)
(kJ)
44
210
44
210
44
210
44
210
44
210
22
420
22
420
22
420
13
435
13
435
8
1800
8
1800
8
1800
6
2400
4
3600
4
3600
44
210
44
210
44
210
44
210
44
210
22
420
22
420
22
420
13
435
13
435
8
1800
8
1800
8
1800
4
3600
4
3600
4
3600
44
248
44
248
44
248
44.
248
22
497
22
497
8
1800
8
1800
8
1800
6
2400
6
2400
.
R
dissipates in 400 seconds.
R
Resistor braking
121
P
Rcont
(kW)
1
1
1
1
1
2
2
2
2
2
4.5
4.5
4.5
6
9
9
1
1
1
1
1
2
2
2
2
2
4.5
4.5
4.5
9
9
9
1
1
1
1
2
2
4.5
4.5
4.5
6
6
PDM code 00096931-G