Sound Pressure
This unit has a sound pressure level at the operator's ear of 92
dBA, which includes an Uncertainty Value (K) of 1 dBA.
The sound pressure level was determined according to the
procedures outlined in EN 836.
Sound Power
This unit has a guaranteed sound power level of 105 dBA,
which includes an Uncertainty Value (K) of 1 dBA.
The sound power level was determined according to the
procedures outlined in ISO 11094.
Vibration Level (Hand-Arm)
Measured vibration level for right hand = 2.6 m/s
Measured vibration level for left hand = 1.9 m/s
Uncertainty Value (K) = 1.3 m/s
Measured values were determined according to the procedures
outlined in EN 836.
Vibration Level (Whole Body)
Measured vibration level = 1.01 m/s
Uncertainty Value (K) = 0.51 m/s
Measured values were determined according to the procedures
outlined in EN 836.