Figure 51
1. Fuel pre-lter
3. Slide the hose clamps onto the ends of the fuel
lines. Push the fuel lines onto the fuel filter
and secure them with the hose clamps. Be sure
that the arrow on the side of the filter points
toward the injection pump.
Bleeding Air from the
Injectors
1. Loosen the pipe connection to the Number
1 injector nozzle and holder assembly at the
injection pump (Figure 52).
Figure 52
1. Number 1 injector nozzle
2. Move the throttle to the Fast position.
3. Turn the key in the ignition switch to the Start
position and watch the fuel flow around the
connector. Turn the key to the Off position
when solid flow is observed.
4. Tighten the pipe connector securely.
5. Repeat the procedure on the remaining nozzles.
Electrical System
Maintenance
Activating, Charging, and
Connecting the Battery
Warning
CALIFORNIA
Proposition 65 Warning
Battery posts, terminals, and related
accessories contain lead and lead
compounds, chemicals known to the State of
California to cause cancer and reproductive
harm. Wash hands after handling.
Note: If the battery is not filled with electrolyte
or activated, bulk electrolyte with 1.260 specific
gravity must be purchased from a local battery
supply outlet and added to the battery.
1. Raise the seat and secure it with the prop rod.
2. Remove the battery cover (Figure 53).
Figure 53
1. Battery cover
3. Remove the filler caps from the battery
(Figure 54) and slowly fill each cell until
electrolyte is just above the plates.