Removal and Installation Routines

Installing the System in the Rack

!
For safety reasons, at least two people are required to install the
server because of its weight and size.
Before lifting the server into the rack, remove server blades, fan units
and power supplies from the system unit to reduce weight.
To lift the server, use the handles on the front and the fold-out handles
on the long sides of the chassis.
Never lift or transport the server using the handles on the rear.
The rack may tip over if more than one unit is removed at the same
time.
Requirements of the rack
The rack systems from Fujitsu Siemens Computers GmbH (PRIMECENTER
rack; DataCenter rack) fully support the installation of the PRIMERGY server
systems. Installation in the common rack systems of other manufacturers
(3rd-party rack) is supported to a large degree.
To accommodate the ventilation concept and ensure proper ventilation of the
components in the rack, any unused areas must be closed using dummy covers.
The power is supplied via the socket strips available in the rack.
The main features of the rack systems from Fujitsu Siemens Computers GmbH
are:
PRIMECENTER/DataCenter rack
– Frontally bolted rails.
The rails have a linear alignment option to also allow adjustment to different
rack depths.
– Extended cable management within the lateral rack area.
The following applies to rack systems from third-party manufacturers:
U41057-J21-Z146-1-76
Installing the System in the Rack