Checking Component Video Output B-Y; Checking Component Video Output R-Y; Checking Rgb Output R; Checking Rgb Output G - Sony DVP-NS300 Service Manual

Hide thumbs Also See for DVP-NS300:
Table of Contents

Advertisement

QQ
3 7 63 1515 0

5. Checking Component Video Output B-Y

(Except AEP, UK, RUS Model)
<Purpose>
This checks component video output B-Y. If it is incorrect, cor-
rect colors will not be displayed when connected to, for instance,
projector.
Mode
Signal
Test point
Instrument
Specification
Checking method:
1) In the test mode initial menu "6" Video Level Adjustment, set
so that color bars are generated.
2) Confirm that the B-Y level is 700 ± 50 mVp-p.

6. Checking Component Video Output R-Y

TE
L 13942296513
(Except AEP, UK, RUS Model)
<Purpose>
This checks component video output R-Y. If it is incorrect, cor-
rect colors will not be displayed when connected to, for instance,
projector.
Mode
Signal
Test point
Instrument
Specification
Checking method:
1) In the test mode initial menu "6" Video Level Adjustment, set
so that color bars are generated.
2) Confirm that the R-Y level is 700 ± 50 mVp-p.
www
.
http://www.xiaoyu163.com
Video level adjustment in test mode
Color bars
COMPONENT VIDEO OUT (P
connector (75 Ω terminated)
Oscilloscope
700 ± 50 mVp-p
700 ± 50 mVp-p
Figure 7-5
Video level adjustment in test mode
Color bars
COMPONENT VIDEO OUT (P
connector (75 Ω terminated)
Oscilloscope
700 ± 50 mVp-p
700 ± 50 mVp-p
Figure 7-6
x
ao
u163
y
i
http://www.xiaoyu163.com
2 9
8
7. Checking RGB Output R (AEP, UK, RUS Model)
<Purpose>
This checks RGB output R. If it is incorrect, pictures will not be
displayed correctly in spite of connection to the TV with an EURO
AV connecting cord.
Mode
)
B
Signal
Test point
Instrument
Specification
Checking method:
1) Confirm that the R level is 700 ± 50 mVp-p.
8. Checking RGB Output G (AEP, UK, RUS Model)
<Purpose>
Q Q
This checks RGB output G. If it is incorrect, pictures will not be
3
6 7
1 3
1 5
displayed correctly in spite of connection to the TV with an EURO
AV connecting cord.
Mode
Signal
)
R
Test point
Instrument
Specification
Checking method:
1) Confirm that the G level is 700 ± 50 mVp-p.
co
.
7-3
9 4
2 8
In test mode,
[0]
Push
for Syscon Diagnosis and
[7]
push
for Video and push
RGB out
Color bars
LINE 1 (RGB)-TV connector
pin qg (75 Ω terminated)
Oscilloscope
700 ± 50 mVp-p
700 ± 50 mVp-p
Figure 7-7
0 5
8
2 9
9 4
2 8
In test mode,
[0]
Push
for Syscon Diagnosis and
[7]
push
for Video and push
RGB out
Color bars
LINE 1 (RGB)-TV connector
pin qa (75 Ω terminated)
Oscilloscope
700 ± 50 mVp-p
700 ± 50 mVp-p
Figure 7-8
m
9 9
[5]
for
9 9
[5]
for

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents