Yamaha DRX-1 Service Manual page 23

Hide thumbs Also See for DRX-1:
Table of Contents

Advertisement

Basic Engine Radial Menu
1.Radial On
2.Radial Off
3.Radial Initialisation
4.Radial ATLS Calibration
Basic Engine Sledge Menu
1.Sledge test
2.Sledge test slow
Basic Engine Tray Menu
1.Tray In
2.Tray Out
DVIO Menu
1.Check Presence
2.Reset
3.Access
4.Error Codes
5.Module Identifiers
6.Led
DVIO Led Menu
1.Led On
2.Led Off
Progressive Scan Board Menu
1.I2C Access
2.Test Image On
3.Test Image Off
Loop Tests Menu
1.Digital Board Loops
2.User/Dealer Loops
3.System Loops
4.Basic Engine Loops
Digital Board Loops Menu
1.Obsolete
2.Digital Video Loop
3.Digital Video Loop VBI
User/Dealer Loops Menu
1.User/Dealer Audio Loop
2.User/Dealer Video Loop
3.User/Dealer Video Loop VBI
System Loops Menu
1.System Video Loop
2.System Video Loop VBI
3.System Audio Loop SCART(EURO)
4.System Audio Loop CINCH (NAFTA)
Basic Engine Loops Menu
1.Basic Engine write read
2.Basic Engine write read endless loop
Log Menu
1.Read Error Log
2.Reset Error Log
->
->
->
->
->
Script Menu
1.User/Dealer Script
2.Player Script
4. Nuclei Error Codes
In the following table the error codes will be described.
Error
Nr Error String
10000
"Checksum is OK"
10001
"segment name Checksum doesn't match"" or
""seg-ment name segment not found"
10100
""
10101
"FLASH 1 Write access test failed"
10200
""
10201
"FLASH 2 Write access test failed"
10300
""
10301
"FLASH write test failed"
10302
"FLASH write command failed"
10303
"FLASH write test done max. number of times"
10400
""
10401
"HostDec SDRAM Memory data bus test goes
wrong."
10402
" HostDec SDRAM Memory address bus test
goes wrong."
10403
" HostDec SDRAM Physical memory device
test goes wrong."
10500
""
10501
" HostDec SDRAM Memory data bus test
goes wrong."
10502
" HostDec SDRAM Memory address bus test
goes wrong."
10503
" HostDec SDRAM Physical memory device
test goes wrong."
10600
""
10601
"HostDec DRAM Memory data bus test goes
wrong."
10602
"HostDec DRAM Memory address bus test
goes wrong."
10603
"HostDec DRAM Physical memory device test
goes wrong."
10700
""
10701
"HostDec DRAM Memory data bus test goes
wrong."
10702
"HostDec DRAM Memory address bus test
goes wrong."
10703
"HostDec DRAM Physical memory device test
goes wrong."
10800
"Host Decoder version(cut) number: version
number""Digital hardware version"
10801
"Can not find version in FLASH."
10900
""
10901
"Error muting audio"
11000
""
11001
"Error demuting audio"
DRX-1
23

Advertisement

Table of Contents
loading

Table of Contents