3 Commissioning
3.2

Commission modes

In the standard version, the MICROMASTER 440 is fitted with the Status Display
Panel (SDP) (see Figure 3-2) with which it is possible to use the inverter with the
pre-assigned factory settings for a large range of applications. If these factory
settings are not suitable, you can adapt them to suit your equipment conditions
using the Basic Operator Panel (BOP) (see Figure 3-2) or the Advanced Operator
Panel (AOP) (see Figure 3-2). The BOP and AOP are available as options. You
can also adjust the factory settings using the PC IBN tool "Drive Monitor" or
"STARTER". This software is available on the CD ROM which comes with the
documentation of the unit.
SDP
Status Display Panel
Figure 3-2
For notes on replacing the operator panels please refer to the corresponding
annexes 0 to this manual.
NOTICE
Frequency setting; the DIP switch is located on the control board, underneath the
I/O board as shown in
Ø DIP switch 2:
♦ Off position:
European
defaults (50 Hz,
kW etc.)
♦ On position: North
American defaults
(60 Hz, hp etc.)
Ø DIP switch 1:
Not for customer use.
36
150.00
Hz
Hz
Basic Operator Panel
Panels available for the MICROMASTER 440 Inverter
below. The inverter is delivered as follows:
Figure 3-3
Analog Setting
DIP Switches
Figure 3-3

Fn
0
jog
P
BOP
DIP switch
MICROMASTER 440
Issue A2
R U N N I N G
f n
P 0 0 0
F =
5 0 . 0
H Z
f l
I = 4 . 8
R P M = 1 5 0 0
p
V = 4 0 0 v
v
1
Fn
menu
0
jog
P
AOP
Advanced Operator Panel
Frequency Setting
DIP Switches
Operating Instructions
6SE6400-5AC00-0BP0