Follow this procedure to configure the E1 ports from the CLI manager.
Action
Log in
Press Enter.
At the username prompt, enter admin.
At the password prompt, enter password.
Set E1 line length
NOTE: If the incorrect line length is selected, the result could be decreased
E1 quality or echo on voice lines. The default length is 133 ft.
Enter
where
[1/2/3/4] represents E1 ports 1 through 4.
[133, 266, 399, 533, 655] represents line length in feet.
RESULT: The system responds
Line [1/2/3/4] length
dB; 266-399 / 1.8 dB; 399-533 / 2.4 dB; 533-655 / 3.0
dB]
Set E1 line code
NOTE: If the line code does not match the incoming E1 settings, then
Bipolar Violations (BPVs) will occur. The default code is HDB3.
Enter set line [1/2/3/4] code [HDB3/AMI]
where
[1/2/3/4] represents E1 ports 1 through 4.
[HDB3/AMI] represents the line coding scheme.
RESULT: The system responds
Line [1/2/3/4] code [HDB3/AMI]
 
Issue 3
 
 
 
 
 

Procedure 12: Configuring the E1 ports using the CLI

set line [1/2/3/4] length [133, 266, 399, 533]
Page 42 of 73 
 
 
 
     
      T1/E1 Multiplexer FPGA Version 3.4 
Steps
[0-133 / 0.6 dB; 133-266 / 1.2
 
September 2004 