18)Image dislocation in feeding direction
Defective area
Scanner/Printer adjust-
ment
Registration roller
Feed clutch
Pre-registration guide
© 2004 - 2007 TOSHIBA TEC CORPORATION All rights reserved
Fig. 5-18
Step
Check items
1
Have the printed images been dislo-
cated in the same manner?
2
Is the registration roller dirty, or the
spring detached?
3
Is the registration roller working prop-
erly?
4
Is the feed clutch working properly?
5
Is the pre-registration guide installed
properly?
5 - 111
Prescription
Adjust the position of the leading
edge of paper in the Adjustment
Mode.
Clean the registration roller with alco-
hol.
Securely attach the springs.
Adjust or replace the gears if they are
not engaged properly.
Check the circuit or feed clutch, and
replace them if necessary.
Install the guide properly.