Administrator's Handbook
set system heartbeat option { on | off }
protocol [ udp | tcp ]
port-client [ 1 - 65535 ]
ip-server [ ip_address | dns_name ]
port-server [ 1 - 65535 ]
url-server (" server_name ")
number [ 1 – 1073741823 ]
interval (00:00:00:20)
sleep (00:00:30:00)
contact-email (" string @ domain_name ")
location (" string "):
The heartbeat setting is used in conjunction with the configuration server to broadcast contact and location
information about your Gateway. You can specify the protocol, port, IP-, port-, and URL-server.
The interval setting specifies the broadcast update frequency. Part of sequence control. The interval is
the spacing between heartbeats, in d:h:m:s.
The contact-email setting is a quote-enclosed text string giving an email address for the Gateway's
administrator.
The location setting is a text string allowing you to specify your geographical or other location, such as
"Secaucus, NJ."
The number setting is part of the sequence control. This is the number of heartbeats to send, at each
"interval", before sleeping. For example, if this is 20, in the above layout, each heartbeat sequence will
send out a total 20 heartbeats, spaced at 30 second intervals, and then sleep for 30 minutes. So to
have the Gateway send out packets "forever", this number can be set very high. If it is 1440 and the
interval is 1 minute, say, the heartbeat will go out every minute for 1440 minutes, or one day, before
sleeping.
The sleep setting is part of sequence control. This is the time to sleep before starting another heart-
beat sequence, in d:h:m:s.
set system ntp
option [ off | on ]:
server-address (north-america.pool.ntp.org)
alt-server-address (pool.ntp.org):
time-zone [ -12 - 12 ]
update-period (60) [ 1 - 65535 ]:
daylight-savings [ off | on ]
Specifies the NTP server address, time zone, and how often the Gateway should check the time from the
NTP server. The NTP server-address and alt-server-address can be entered as DNS names as well as IP
addresses. NTP time-zone of 0 is GMT time; options are -12 through 12 (+/- 1 hour increments from GMT
time). update-period specifies how often, in minutes, the Gateway should update the clock. daylight-sav-
ings specifies whether daylight savings time is in effect; it defaults to off.
set system zerotouch option [ on | off ]
Enables or disables the Zero Touch option.