Toshiba e-STUDIO200L Service Manual page 175

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO200L:
Table of Contents

Advertisement

[E] Exposure lamp
(1)
Take off the original glass
(
P.6-17 "[A] Original glass").
(2)
Take off the front upper cover
(
P.2-32 "[E] Front upper cover").
(3)
Move the carriage-1 to the center position
where the side of the frame is cut out.
Note:
Rotate the drive pulley to move the carriage.
(4)
Disconnect 1 connector from the inverter
board. Pull out the harness from 2 harness
clamps and the frame of the carriage.
Note:
When disconnecting the connector, make
sure not to overload the carriage frame.
© 2004 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Fig. 6-29
Fig. 6-30
Fig. 6-31
e-STUDIO200L/202L/203L/230/232/233/280/282/283
6 - 21
Carriage-1
Drive pulley