Sign In
Upload
Manuals
Brands
Thermo Scientific Manuals
Accessories
HERACELL VIOS 250i
Thermo Scientific HERACELL VIOS 250i Manuals
Manuals and User Guides for Thermo Scientific HERACELL VIOS 250i. We have
2
Thermo Scientific HERACELL VIOS 250i manuals available for free PDF download: User Manual, Supplement To Operating Instructions
Thermo Scientific HERACELL VIOS 250i User Manual (200 pages)
CO2 Incubator
Brand:
Thermo Scientific
| Category:
Accessories
| Size: 7.28 MB
Table of Contents
Table of Contents
3
Preface
13
General Notes
13
Identification of the Device and of the Documentation
13
Identification of the Device
13
Instruction of the Operating Personnel
13
Applicability of the Instructions
14
Original Document for Translation
14
Warranty
14
Requirements for Warranty
14
Explanation of Safety Information and Symbols
15
Safety Information and Symbols Used in the Operating Instructions
15
Additional Symbols for Safety Informations
16
Symbols on the Device
17
Intended Purpose of the Device
17
Correct Use
17
Incorrect Use
18
Standards and Directives
18
Safety Notes on Gases
19
Instruction of the Personnel
19
Safety Notes on Carbon Dioxide (CO2)
19
Safety Notes on Oxygen (O2)
20
Safety Notes on Nitrogen (N2)
20
Chapter 1 Delivery of the Incubator
21
Packaging
21
Acceptance Inspection
21
Standard Equipment Components HERACELL VIOS 160I / 250I
22
Optional Equipment Components HERACELL VIOS 160I / 250I
22
Optional Equipment Components HERACELL VIOS 160I
22
Optional Equipment Components HERACELL VIOS 250I
23
Chapter 2 Installation of the Device
25
Environmental Conditions
25
Requirements
25
Room Ventilation
26
Space Requirements
26
Figure 2-1. Device Dimensions
26
Transport
27
Stacking
27
Figure 2-2. Lift Points
27
Figure 2-3. Stacking
28
Figure 2-4. Stacking Adapter and Base Rack with Stacking Elements
29
Figure 2-5. Fastening the Adapter Plate to the Lower Unit
29
Retrofitting/Modifications
30
Chapter 3 Description of the Device
31
HERACELL VIOS 160I / VIOS 250I Front View
31
HERACELL VIOS 160I / VIOS 250I Rear View
31
Safety Devices HERACELL VIOS 160I / VIOS 250I
36
Workspace Atmosphere
36
Temperature
36
Relative Humidity
37
Water Quality Recommendations
37
Prefilter
37
HEPA-Filter and Air Duct
38
Figure 3-4. HEPA-Filter and Airbox
38
CO2 Supply
39
O2 Supply
39
Figure 3-5. Air Duct
39
N2 Supply
40
Door Switch
40
Figure 3-6. Door Switch
40
Sensor System
41
Figure 3-8. Sensors for Water Level
42
Supply Interface
43
Standard Interfaces
43
Figure 3-9. Interfaces (Right Side of Control Box)
43
Optional Interfaces
44
Figure 3-10. Optional Interfaces (Left Side of Control Box)
44
Gas Connection
45
Label
45
USB Interface
45
4-20 Ma Interface
45
Alarm Contact
46
Power Supply Connection
46
Workspace Components
47
Interior Container
47
Glass Door and Optional Gas-Tight Screen
47
Figure 3-11. HERACELL VIOS 160I with Glass Door
48
Water Reservoir
49
Figure 3-12. HERACELL VIOS 160I with Threefold Gas-Tight Screen
49
Figure 3-13. Water Reservoir
50
Figure 3-14. Drain Valve of Water Reservoir
50
Heating System
51
Rear Panel Openings
51
Figure 3-15. Rear Panel Openings
51
Shelf System
52
Figure 3-16. Shelf System Components
52
Chapter 4 Start-Up
53
Adapting the Unit to the Ambient Atmosphere
53
Preparing the Workspace
53
Installing the "MAX" Fill Level Indicator and the Pre-Filter
54
Figure 4-1. "MAX" Fill Level Indicator
54
Figure 4-2. „MAX" Fill Level Indicator and Pre-Filter
55
Install the Air Duct
56
Figure 4-3. Assembling the Air Duct
56
Installing the HEPA-Filter and the Water Reservoir Cover Panel
57
Figure 4-4. Assembling the HEPA-Filter and the Airbox
57
Figure 4-5. Place the Airbox Onto the Water Reservoir Cover Panel
58
Figure 4-6. Installing the Airbox
58
Installing the Shelf System
59
Installation/Removal of the Support Rail
59
Figure 4-7. Support Rail Installation/Removal
59
Shelf Support Installation
60
Levelling the Device
60
Figure 4-8. Shelf Support Installation
60
Mount the Split Inserts (Optional) into the HERACELL VIOS 250I
61
Figure 4-9. Installation of Split Inserts
61
Gas Connection
62
Installing Gas Pressure Hoses
62
Figure 4-10. Installing Gas Pressure Hoses
62
Gas Connection Without Gas Monitoring System
63
Figure 4-11. Gas Connection Without Gas Monitoring System
63
CO2 Connection with Gas Monitoring System (Optional)
64
Power Supply Connection
67
Figure 4-14. Power Supply Connection
67
Connecting the USB Interface
68
Connecting the Alarm Contact
68
Figure 4-15. Connection Example Alarm Contact
69
Connecting the 4-20 Ma Interface
70
Figure 4-16. Pin-Out of the 4-20 Ma Interface
70
Chapter 5 Operation
71
Preparing the Device
71
Starting Operation
73
Figure 5-1. Water Reservoir
73
Figure 5-2. "MAX" Fill Level Indicator
74
Chapter 6 Handling and Control
77
Power Switch
78
Figure 6-1. Power Switch
78
Operating Panel and Operating Structure
79
Figure 6-2. Main Screen: Touch-Sensitive Screen Areas
79
Versions Without O2/N2 Control
80
Figure 6-4. Ican™ Touchscreen with Combined Gas Connection
81
Structure of the Operating Levels
81
Version with Combined CO2/O2/N2 Control (Optional)
81
Figure 6-5. Menu Structure Overview
82
Factory Presettings of the Ican™ Touchscreen Controls
83
Heat-Up Phase of the Control Loop Sensors
83
Figure 6-6. Heat-Up Phase Display
83
Behavior of Keys During Adjustments
84
Setting the Temperature Set Value
84
Figure 6-7. Temperature Display Field and Temperature Selection Menu
84
Setting the CO2 Set Value
85
Figure 6-8. Setting the Temperature Set Value
85
Figure 6-9. CO2 Display and CO2 Menu
85
Setting the O2 Set Value
86
Figure 6-10. Setting the CO2 Set Value
86
Figure 6-11. O2 Display and O2 Menu
87
Figure 6-12. Setting the O2 Set Value
87
Auto-Start Function
88
Activating the Auto-Start Routine
90
Figure 6-13. Activating the Auto-Start Routine
90
Interrupting the Auto-Start Routine
91
Figure 6-14. Auto-Start-Status Display Window
91
Launching Steri-Run
92
Figure 6-15. Interrupting the Auto-Start Routine
92
Figure 6-16. Error Message Subsequent to Aborted Auto-Start
92
User Configuration
93
Settings / Setup
93
Figure 6-17. User Configuration Menu
93
Figure 6-18. Settings/Setup Menu
94
Figure 6-19. Changing the Keypad Lock Code
94
Figure 6-20. Changing the Keypad Lock Code
95
Figure 6-21. Date/Time Menu
96
Figure 6-22. Setting the Date
96
Figure 6-23. Setting the Time
97
Figure 6-24. Adjusting Display Brightness
98
Figure 6-25. Adjusting Key Tone Volume
99
Figure 6-26. Interface USB Menu
100
Figure 6-27. USB Interface Baud Rate Setting
100
Figure 6-28. Language Setting
101
Figure 6-29. Choose the Desired Reminder Interval Function
102
Data Logging
103
Figure 6-30. Setting the Reminder Interval for Steri-Run
103
Figure 6-31. Event Logging Menu
104
Figure 6-32. Event Display
104
Figure 6-33. Logging Cycle Setting
105
Options
107
Figure 6-34. Displaying the Error Table
107
Figure 6-35. Options Menu
108
Figure 6-36. Alarm Menu
108
Figure 6-37. Alarm Relay Setting
109
Figure 6-38. Low Humidity Setting
110
Figure 6-39. Gas Tight Screen Setting
111
Figure 6-40. Setting the Water Level Sensor
112
Figure 6-41. Alarm Relay Setting
113
Figure 6-42. Switching the O2 Control on and off
114
Figure 6-43. HEPA Configuration
115
Figure 6-44. Activating / De-Activating the HEPA-Filter
115
Icon Description
116
Figure 6-45. Icon Description
116
Figure 6-46. Gas Monitoring Icons
117
Enabling/Disabling the Keypad Lock
118
Software Versions
119
Trend Display Scaling
119
Figure 6-47. Enabling/Disabling the Keypad Lock
119
Figure 6-48. Software Versions
119
Figure 6-49. Invoking the CO2 Concentration Graph Display
120
Figure 6-50. Invoking the CO2 Concentration Graph Display
120
Error Messages
121
Response to an Error Message Event
121
Resetting Overtemperature Protection
122
Figure 6-51. Event Error Messages
122
Figure 6-52. Failure Message Overtemperature
122
Measures after Power Outage
123
Figure 6-53. Failure Message Overtemperature
123
Troubleshooting
124
Chapter 7 Shut-Down
129
Shutting the Device down
129
Figure 7-1. Drain Valve of Water Reservoir
129
Chapter 8 Cleaning and Disinfection
131
Cleaning
131
Decontamination Procedures
132
Preparing for Disinfection or Steri-Run
132
Figure 8-1. Drain Valve of Water Reservoir
132
Wipe/Spray Disinfection
133
Figure 8-2. HEPA-Filter and Airbox
135
Figure 8-3. Air Duct
136
Steri-Run Decontamination Routine
137
Activating Steri-Run
139
Figure 8-4. Decontamination Routine Phases
139
Figure 8-5. Steri-Run Menu - Progress
139
Cancel Steri-Run
140
Figure 8-6. Activate Steri-Run
140
Figure 8-7. Interrupting / Cancelling Steri-Run
141
Steri-Run Interruption Due to Error
141
Completing Steri-Run
142
Figure 8-8. to Stop Steri-Run
142
Chapter 9 Maintenance
144
Service Intervals
144
Preparing Temperature Calibration
144
Temperature Calibration Procedure
145
Figure 9-1. Preparing Temperature Calibration
145
Figure 9-2. Temperature Display Field and Temperature Selection Menu
146
Figure 9-3. Temperature Calibration Procedure
146
Preparing the CO2 Calibration
147
CO2 Calibration Procedure
148
Figure 9-4. Gas-Tight Screen Measurement Opening
148
Replacing the HEPA-Filter
149
Figure 9-5. CO2 Calibration Procedure
149
Figure 9-6. Removing the Airbox
150
Replacing the Gas Inlet Filter
151
Figure 9-7. Installing the HEPA-Filter
151
Device Fusing Replacement
152
Figure 9-8. Gas Inlet Filter Installation
152
Replacing the Door Seal
153
Chapter 10 Waste Disposal
155
Overview of the Materials Used
155
Chapter 11 Specifications
157
HERACELL VIOS 160I
157
HERACELL VIOS 250I
157
HERACELL VIOS 250I
162
Chapter 12 Annex: Data Communication
167
Installing the USB Port Driver
168
Structure of the Command Sequences for Data Communication
170
Description of Protocol
170
Overview of General Parameters (Addresses 0Xxx)
171
Reading General Parameters
171
Overview of Incubator Parameters (Addresses 2Xxx)
171
Reading Basic Parameters
172
Reading Internal Function Parameters
173
Error Memory Structure
174
Error Memory Data Set Structure Scheme
175
Overview of the Possible Error Messages in Hex Coding
176
Overview of the Possible Error Messages in Bit Coding General Device Status, Temperature and CO2 Control Loop
176
O2 Control Loop and Water Level
177
Data Logger Structure
177
Data Logger Data Set Structure Scheme
179
Overview of Possible Event Entries in Bit Coding
180
Overview of Event Entries, Part I
180
Examples of Data Logger Codes
181
Functions for Data Logger Queries
182
Example of a Code for a a Data Logger Query
182
Program HERACELL VIOS 160I / HERACELL VIOS 250I
187
Installing the HERACELL VIOS 160I & HERACELL VIOS 250I
188
Operating the HERACELL VIOS 160I & HERACELL VIOS 250I
189
Chapter 13 Device Log
195
Chapter 14 Contact Information Thermo Scientific
197
Advertisement
Thermo Scientific HERACELL VIOS 250i Supplement To Operating Instructions (20 pages)
CO2 Incubators
Brand:
Thermo Scientific
| Category:
Laboratory Equipment
| Size: 1.06 MB
Advertisement
Related Products
Thermo Scientific Heracell 240i
Thermo Scientific Heracell Vios 250i CR
Thermo Scientific 2076 Series
Thermo Scientific 2862
Thermo Scientific 2863 253
Thermo Scientific Heracell Vios 160i CR
Thermo Scientific HERACELL VIOS 160i
Thermo Scientific 25LCEETSA
Thermo Scientific VARIOKLAV 25T
Thermo Scientific ESCALAB 250
Thermo Scientific Categories
Laboratory Equipment
Measuring Instruments
Accessories
Freezer
Refrigerator
More Thermo Scientific Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL