Sign In
Upload
Manuals
Brands
Siemens Manuals
Wireless modules
TC37 Module
Siemens TC37 Module Wireless Manuals
Manuals and User Guides for Siemens TC37 Module Wireless. We have
1
Siemens TC37 Module Wireless manual available for free PDF download: At Command Reference
Siemens TC37 Module At Command Reference (204 pages)
AT Command Set Cellular Engines
Brand:
Siemens
| Category:
Wireless modules
| Size: 1.97 MB
Table of Contents
Table of Contents
3
Version History
7
1 Introduction
10
Scope of the Document
10
Supported Product Versions and Related Documents
10
Conventions
11
AT Command Syntax
11
Using Parameters
11
Combining at Commands on the same Command Line
12
Entering Successive at Commands on Separate Lines
12
Supported Character Sets
13
Flow Control
14
Software Flow Control (XON/OFF Flow Control)
14
Hardware Flow Control (RTS/CTS Flow Control)
14
2 Standard V.25Ter at Commands
15
A/ Repeat Previous Command Line
15
Switch from Data Mode to Command Mode
15
At\Qn Flowcontrol
16
ATA Answer a Call
16
ATD Mobile Originated Call to Dial a Number
17
Atd><Mem><N> Originate Call to Phone Number <N> in Memory <Mem
18
Atd><N> Originate Call to Phone Number Selected from Active Memory
20
Atd><Str> Originate Call to Phone Number in Memory with Corresponding Field
21
ATDI Mobile Originated Call to Dialable ISDN Number <N
22
ATDL Redial Last Telephone Number Used
23
ATE Enable Command Echo
24
ATH Disconnect Existing Connection
24
ATI Display Product Identification Information
25
Ati[Value] Display Additional Identification Information
25
ATL Set Monitor Speaker Loudness
26
ATM Set Monitor Speaker Mode
26
ATO Switch from Command Mode to Data Mode
26
ATQ Set Result Code Presentation Mode
27
ATP Select Pulse Dialling
27
ATS0 Set Number of Rings before Automatically Answering the Call
27
ATS2 Escape Code Sequence
28
ATS3 Write Command Line Termination Character
28
ATS4 Set Response Formatting Character
28
ATS5 Write Command Line Editing Character
29
ATS6 Set Pause before Blind Dialling
29
ATS7 Set Number of Seconds to Wait for Connection Completion
30
ATS8 Set Number of Seconds to Wait for Comma Dial Modifier
30
ATS10 Set Disconnect Delay after Indicating the Absence of Data Carrier
31
ATS18 Extended Error Report
31
ATT Select Tone Dialling
31
ATV Set Result Code Format Mode
32
ATX Set CONNECT Result Code Format and Call Monitoring
32
ATZ Set All Current Parameters to User Defined Profile
33
AT&C Set Circuit Data Carrier Detect (DCD) Function Mode
33
AT&D Set Circuit Data Terminal Ready (DTR) Function Mode
34
AT&F Set All Current Parameters to Manufacturer Defaults
34
AT&S Set Circuit Data Set Ready (DSR) Function Mode
35
AT&V Display Current Configuration
36
AT&W Store Current Configuration to User Defined Profile
37
AT+GCAP Request Complete TA Capabilities List
38
AT+GMI Request Manufacturer Identification
38
AT+GMM Request TA Model Identification
38
AT+GMR Request TA Revision Identification of Software Status
39
AT+GSN Request TA Serial Number Identification(IMEI)
39
AT+ILRR Set TE-TA Local Rate Reporting
40
AT+IPR Set Fixed Local Rate
41
Autobauding
42
3 AT Commands for FAX
43
AT+FBADLIN Bad Line Threshold
43
AT+FBADMUL Error Threshold Multiplier
44
AT+FBOR Query Data Bit Order
44
AT+FCIG Query or Set the Local Polling ID
45
AT+FCLASS Fax: Select, Read or Test Service Class
45
AT+FCQ Copy Quality Checking
46
AT+FCR Capability to Receive
46
AT+FDCC Query or Set Capabilities
47
AT+FDFFC Data Compression Format Conversion
48
AT+FDIS Query or Set Session Parameters
49
AT+FDR Begin or Continue Phase C Data Reception
50
AT+FDT Data Transmission
50
AT+FET End a Page or Document
51
AT+FK Kill Operation, Orderly FAX Abort
51
AT+FLID Query or Set the Local ID Setting Capabilities
51
AT+FMDL Identify Product Model
52
AT+FMFR Request Manufacturer Identification
52
AT+FOPT Set Bit Order Independently
52
AT+FPHCTO DTE Phase C Response Timeout
53
AT+FREV Identify Product Revision
53
AT+FRH Receive Data Using HDLC Framing
53
AT+FRM Receive Data
54
AT+FRS Receive Silence
54
AT+FTH Transmit Data Using HDLC Framing
54
AT+FTM Transmit Data
55
AT+FTS Stop Transmission and Wait
55
AT+FVRFC Vertical Resolution Format Conversion
56
4 AT Commands Originating from GSM 07.07
57
AT+CACM Accumulated Call Meter (ACM) Reset or Query
57
AT+CALA Set Alarm Time
58
AT+CAMM Accumulated Call Meter Maximum (Acmmax) Set or Query
61
AT+CAOC Advice of Charge Information
62
AT+CBST Select Bearer Service Type
63
AT+CCFC Call Forwarding Number and Conditions Control
64
Examples: Call Forwarding
65
AT+CCLK Real Time Clock
67
AT+CEER Extended Error Report
68
AT+CFUN Set Phone Functionality
69
AT+CGMI Request Manufacturer Identification
71
AT+CGMM Request Model Identification
71
AT+CGMR Request Revision Identification of Software Status
71
AT+CGSN Request Product Serial Number Identification (IMEI) Identical to GSN
72
AT+CHLD Call Hold and Multiparty
72
AT+CHUP Hang up Call
73
AT+CIMI Request International Mobile Subscriber Identity
73
AT+CLCC List Current Calls of ME
74
AT+CLCK Facility Lock
75
Examples: Enabling / Disabling PIN 1 Authentication
77
Examples: Phone Lock
77
Examples: Call Barring
79
AT+CLIP Calling Line Identification Presentation
81
AT+CLIR Calling Line Identification Restriction (by *# Sequence)
82
AT+CLVL Loudspeaker Volume Level
83
AT+CMEE Report Mobile Equipment Error
84
AT+CMUT Mute Control
85
AT+CMUX Enter Multiplex Mode
86
Restricted Use of at Commands in Multiplex Mode
87
AT+COPN Read Operator Names
89
AT+COPS Operator Selection
90
AT+CPAS Mobile Equipment Activity Status
92
AT+CPBR Read Current Phonebook Entries
93
AT+CPBS Select Phonebook Memory Storage
94
AT+CPBW Write Phonebook Entry
95
AT+CPIN Enter PIN
96
What to Do if PIN or Password Authentication Fails
99
AT+CPIN2 Enter PIN2
101
AT+CPUC Price Per Unit and Currency Table
103
AT+CPWD Change Password
104
AT+CR Service Reporting Control
106
AT+CRC Set Cellular Result Codes for Incoming Call Indication
107
AT+CREG Network Registration
108
AT+CRLP Select Radio Link Protocol Param. for Orig. Non-Transparent Data Call
110
AT+CRSM Restricted SIM Access
111
AT+CSCS Set te Character Set
112
AT+CSNS Single Numbering Scheme
113
AT+CSQ Signal Quality
114
AT+CSSN Supplementary Service Notifications
115
AT+CUSD Unstructured Supplementary Service Data
116
At+Vtd=<N> Tone Duration
117
AT+VTS DTMF and Tone Generation (<Tone> in {0-9, *, #, A, B, C, D})
118
AT+WS46 Select Wireless Network
119
5 AT Commands Originating from GSM 07.05 for SMS
120
AT+CMGC Send an SMS Command
120
AT+CMGD Delete SMS Message
121
AT+CMGF Select SMS Message Format
121
AT+CMGL List SMS Messages from Preferred Store
122
AT+CMGR Read SMS Message
125
AT+CMGS Send SMS Message
128
AT+CMGW Write SMS Message to Memory
130
AT+CMSS Send SMS Message from Storage
132
AT+CNMA New SMS Message Acknowledge to ME/TE, Only Phase 2
133
AT+CNMI New SMS Message Indications
134
AT+CPMS Preferred SMS Message Storage
137
AT+CSCA SMS Service Centre Address
138
AT+CSCB Select Cell Broadcast Messages
139
AT+CSDH Show SMS Text Mode Parameters
140
AT+CSMP Set SMS Text Mode Parameters
141
AT+CSMS Select Message Service
142
6 Siemens Defined at Commands for Enhanced Functions
143
AT+CXXCID Display Card ID (Identical to AT^SCID)
143
AT^MONI Monitor Idle Mode and Dedicated Mode
144
AT^MONP Monitor Neighbour Cells
146
AT^SACM Advice of Charge and Query of ACM and Acmmax
147
AT^SBC Battery Charging / Discharging and Charge Control
148
AT^SCID Display SIM Card Identification Number
151
AT^SCKS Set SIM Connection Presentation Mode and Query SIM Connection Status
152
AT^SCNI List Call Number Information
153
AT^SCTM Set Critical Operating Temperature Presentation Mode or Query Temperature
154
AT^SDLD Delete the "Last Number Redial" Memory
156
AT^SHOM Display Homezone
156
AT^SLCD Display Last Call Duration
156
AT^SLCK Facility Lock
157
AT^SMGL List SMS Messages from Preferred Storage
158
AT^SMGO Set or Query SMS Overflow Presentation Mode or Query SMS Overflow
159
AT^SMGR Read SMS Message Without Set to REC READ
160
AT^SMONC Cell Monitoring
161
AT^SMSO Switch off Mobile Station
162
AT^SM20 Set M20 Compatibility
162
AT^SNFD Set Audio Parameters to Manufacturer Default Values
163
AT^SNFI Set Microphone Path Parameters
163
AT^SNFM Mute Microphone
164
Audio Programming Model
164
AT^SNFO Set Audio Output (= Loudspeaker Path) Parameter
165
AT^SNFPT Call Progress Tones
166
AT^SNFS Select Audio Hardware Set
167
AT^SNFV Set Loudspeaker Volume
168
AT^SNFW Write Audio Setting in Non-Volatile Store
168
AT^SPBC Search the First Entry in the Sorted Telephone Book
169
AT^SPBG Read Entry from Active Telephone Book Via Sorted Index
170
AT^SPBS Steps the Selected Phonebook Alphabetically
171
AT^SPIC Display PIN Counter
172
AT^SPLM Read the PLMN List
173
AT^SPLR Read Entry from the Preferred Operators List
174
AT^SPLW Write an Entry to the Preferred Operators List
175
AT^SPWD Change Password for a Lock
176
AT^SSCONF SMS Configuration
177
AT^SSDA Set Display Availability
178
AT^SSYNC Configure SYNC Pin
179
AT^STCD Display Total Call Duration
180
7 Appendix
181
Summary of ERRORS and Messages
181
Summary of CME ERRORS Related to GSM 07.07
181
Summary of CMS ERRORS Related to GSM 07.05
183
Summary of Unsolicited Result Codes (URC)
185
Result Codes
187
Cause Location ID for the Extended Error Report (AT+CEER)
187
GSM Release Cause for L3 Radio Resource (RR) (AT+CEER)
188
SIEMENS Release Cause for L3 Radio Resource (RR) (AT+CEER)
188
GSM Release Cause for Mobility Management (MM) (AT+CEER)
189
SIEMENS Release Cause for L3 Mobility Management (MM) (AT+CEER)
189
GSM Release Cause for L3 Call Control (CC) (AT+CEER)
190
SIEMENS Release Cause for L3 Call Control (CC) and Mobile Station Manager (MSM) (AT+CEER)
191
SIEMENS Release Cause for L3 Advice of Charge (AOC) (AT+CEER)
192
GSM Release Cause for Supplementary Service Call (AT+CEER)
192
SIEMENS Release Cause for Call-Related Supplementary Services (CRSS) (AT+CEER)
193
Summary of PIN Requiring at Commands
194
AT Commands Available before Entering the SIM PIN
196
Standard GSM Service Codes
198
Additional Notes on ^SCCFC, ^SCCWA, ^SCLCK
200
GSM and UCS2 Alphabet Tables
202
Advertisement
Advertisement
Related Products
Siemens TC35
Siemens tc35it
Siemens TC35i Terminal
Siemens TC3A...GB
Siemens TC3A GB Series
Siemens TC 3A Series
Siemens TC3A-107
Siemens TC3 Series
Siemens TC3A0307
Siemens TC3A0303
Siemens Categories
Industrial Equipment
Controller
Oven
Control Unit
Washer
More Siemens Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL