Sign In
Upload
Manuals
Brands
SICK Manuals
Card Reader
Lector 620
SICK Lector 620 Manuals
Manuals and User Guides for SICK Lector 620. We have
2
SICK Lector 620 manuals available for free PDF download: Online Help Manual, Operating Instructions Manual
SICK Lector 620 Online Help Manual (166 pages)
Image-Based Code Reader
Brand:
SICK
| Category:
Card Reader
| Size: 3.82 MB
Table of Contents
Table of Contents
3
1 Notes on this Document
13
2 Software Interface
15
3 Online Images
16
Image History
18
Code Infobox
19
Statistics
20
4 Stored Images
21
Saved Images
21
Image History
22
Code Infobox
23
5 Parameters
25
General
25
Configuration Is Password Protected
25
Auto Setup Via Function Button Menu
25
Change Reading Distance
26
Change Camera Settings
26
Change Code Settings
26
Function Buttons
26
Function
26
Reading Configuration
27
Camera and Lighting
27
Reading Distance
27
Y269/2013
27
Auto
29
Exposure Time
29
Reading Distance
29
Brightness
30
Exposure Time
30
Image Settings
30
Auto
31
Contrast
31
Illumination
31
Internal
31
Aiming Laser
32
Duration
33
Green Feedback Spot
33
Image Filters
33
Noise Suppression
33
Dot Size
34
Increase Performance
34
Image Frequency Input Field
35
Image Region of Interest
35
Image Rotation 180
35
Setting Image Frequency Manually
35
Object Trigger Control
35
Start by
36
Start Delay
36
Starting/Stopping the Object Trigger
36
Trigger Delay
36
Stop Delay
37
Stop by
38
Reading Gate Length
39
Pause
40
Pulse
40
Reading Gate off
41
Reading Gate on
41
Trigger Echo on
41
Trigger Distribution
41
Distribution
42
Position
42
Coordinates
42
X-Coordinate
42
Y-Coordinate
42
Z-Coordinate
42
Angle
42
Alpha
42
Beta
43
Gamma
43
Increment Configuration
43
Increment
43
Increment Source
43
Fixed Speed
44
System Increment Resolution
44
Code Configuration
44
General
44
Automatic Code Configuration
44
1D Symbologies
44
Minimum Module Width
44
Codabar
45
Code 39
45
Upc/Gtin/Ean
45
2/5 Interleaved
46
Code 128 Family
46
Code 93
46
GS1 Databar
47
Pdf417
47
Pharmacode
47
Stacked Codes
47
Increase 1D Performance
48
Code Background
48
Code Contrast
48
2D Code Types
48
Data Matrix
49
Minimum Cell Size
49
Increase 2D Performance
50
Code Alignment
50
Code Background
50
Code Contrast
50
Codabar
51
General
51
Multiread
51
Start/Stop Identical
51
Check Digit Test
52
Code Length
52
Length
52
Outputting Start/Stop
52
Code 39
53
Fixed Length
53
General
53
Interval
53
Multiread
53
C32 Conversion
54
Check Digit Test
54
Full ASCII
54
Transmit Start/Stop
54
Code Length
55
Fixed Length
55
Hex - ASCII Output
55
Interval
55
Length
55
Upc/Gtin/Ean
55
Add-On
56
General
56
Multiread
56
Upc
56
Upc a
56
Ean
57
Gtin 13 / Ean 13
57
Gtin 8 / Ean 8
57
Upc E
57
UPC E Extended
57
2/5 Interleaved
58
Check Digit Test
59
Check-Digit-Test #2
59
Check-Digit-Test #3
59
Check-Digit-Test #4
59
Check-Digit-Test #5
59
General
59
Length
59
Multiread
59
Code 93
60
Code Length
60
Fixed Length
60
Interval
60
Code Length
61
Fixed Length
61
General
61
Interval
61
Length
61
Multiread
61
Code 128
62
Code 128 Family
62
Ean 128
62
General
62
Code Length
63
Interval
63
Length
63
Multiread
63
FC1-Value on First Position
64
FC1-Value Within Code
64
Fixed Length
64
General
64
GS1 Databar
64
Gs1/Ean 128
64
Databar 14
65
Databar Expanded
65
Databar Limited
66
Pharmacode
66
General
66
Fixed Length
67
Module Width
67
Multiread
67
Not Calibratable
67
Reverse
67
Data Matrix
67
Activate ISO15415 Verification
68
Code Format
68
General
68
Length
68
Max. Permissible Error Correction
68
Fixed Length 1
69
Fixed Length 2
69
Fixed Length 3
69
Symbol Size
69
Allow Rectangular Data Fields
70
Code Surrounded by Patterns
70
Code Surrounded by Text
70
Fixed Length 4
70
Fixed Length 5
70
Reducing Evaluation Time
70
Decoding
71
Errors in L-Pattern
71
GS1 Format
71
Increasing Robustness
71
Replacing the FNC1 Character
71
Replacing the Separator
73
Application Identifier Marking
74
Pdf 417
74
General
74
Data Processing
75
Collection of Data
75
Timeout
75
Code Summarization
75
Code Distance
75
Separate Codes Depending on Position
75
Separate Codes Dependent on Sensor
76
Output Control
76
Control
76
Output Condition
76
Output Time
76
Condition Timeout
77
Data Output Mode
77
Delay
77
Label Timeout
77
Output Delay
77
Certain Numb. of New Labels
78
Label Timeout Active
78
Timeout
78
Evaluation Conditions
78
Conditions for Good Read
78
Check Max. Number of Valid Codes
79
Check Min. Number of Valid Codes
79
Evaluation Conditions
79
Activating Teach-In Mode
80
Match Code
80
Matchcode Teach-In 1
80
Inverting a Condition
81
Or Teach-In Via Function Buttons
81
Teach-In Code Content
81
Teach-In Code ID (Type)
81
Teach-In Condition
81
Teach-In Stop by
81
Activate Teach-In Mode
82
Match-Code Teach-In 2 (Additional)
82
Teach-In Code Length
82
Invert Condition
83
Teach-In Code Content
83
Teach-In Code ID (Type)
83
Teach-In Code Length
83
Teach-In Condition
83
Teach-In Stop by
83
Allowed Code Types
84
Code Configuration
84
General Match Code Teach-In - Settings
84
Start Teach-In
84
Filters/Sorters for Output Format1
85
Filters/Sorters for the Output Formatting
85
Save Permanent
85
Filters/Sorters for Output Format2
91
Output Format
96
Output Format 1
96
Output Format 2
102
Heartbeat Format
107
Data Forwarding
108
Rx Header
108
Rx Terminator
108
Serial Input Data
108
Target Interface
108
Auxiliary Input/Auxiliary Read Result
109
Bar Code Type
109
Rx Header
109
Rx Terminator
109
Tx Header
109
Tx Terminator
109
Code Ids for Bar Codes
110
EDS Text Element in Output Format / Element Output Format
110
Application Counter
111
Application Counters
111
Default Text
111
Rx Header
111
Rx Terminator
111
Application Counter
112
Resetting Counter Statuses
112
Saving Current Counter Statuses
112
Saving the Counter State Permanently
113
Value
113
Analysis Tools
113
Device Time
113
Time Server IP Address
113
Time Source
113
Connection Timeout
114
Date (YYYY-MM-DD)
114
Port
114
Time (Hh:MM:ss)
114
Time Difference to GMT
114
Image Diagnosis
114
Image Diagnostic
114
Conditions for Image Storing
115
Image Selection
115
Prioritizing Image Output over the Trigger
115
Image Quality
116
Internal Memory (Permanent)
116
Save Destination
116
Internal Memory (Temporary)
117
Microsd Card
117
Sopas (Pc)
118
Date
119
Folder Name
119
Image File Path
119
Good Read / no Read File Prefix
120
Hour
120
Image File Name
120
Subfolder Good Read / no Read
120
Network/Interfaces/Ios
120
Network Options
121
Device ID
121
Device Name
121
Master/Slave
121
Function
122
Slave List
122
Multiplexer/Server
122
Function
123
Server List
123
Monitoring
123
Assign to
123
Max. Startup Time for the Monitored Devices
123
Monitored Devices
123
Serial
123
Serial Host
123
Baud Rate
124
Data Bits / Parity
124
Enable Heartbeat
124
Hardware
124
Multiplexer Output
124
Output Format 1
124
Stop Bits
124
With Number
124
Handling Input Data
125
Heartbeat Interval
125
Output Format
125
Restart Interval on Sending
125
Serial aux
125
Enable Heartbeat
126
Handling Input Data
126
Heartbeat Interval
126
Rdt ID
126
Restart Interval on Sending
126
Addressing Mode
127
Default Gateway
127
Ethernet
127
Ethernet General
127
IP Address
127
Subnet-Mask
127
Ethernet Host Port
128
IP Port
128
MAC-Address
128
Multiplexer Output
128
Negotiated
128
Output Format 1
128
Server/Client
128
Speed
128
Enable Heartbeat
129
Ethernet aux Port
129
Heartbeat Interval
129
Output Format 1
129
Restart Interval on Sending
129
Server Address
129
Activate Ethernet/Ip
130
Assembly Size Output on the PLC
130
Communication Protocol
130
Ethernet/Ip
130
IP Port
130
Protocol/Output Format
130
Server/Client
130
Activate Web Server at Device Startup
131
Assembly Size Input on the PLC
131
Monitored Ports
131
Monitoring
131
Serial Host Interface (Port 4003)
131
Web Server
131
5.10.10 Can
132
DHCP Fallback Mode
132
Mode
132
Serial Auxiliary Interface (Port 4002)
132
Using Device ID as a Node ID
132
Data Transmission Rate
133
Device ID
133
Enable Heartbeat
133
Heartbeat Interval
133
Mask for Digital Input
133
Output Format
133
Restart Interval on Sending
133
5.10.10.1.11 COB ID RPDO Digital Input
134
Enable Digital Output
134
COB ID TPDO Digital Output
135
COB ID RPDO User Digital Input
136
COB ID TPDO User Digital Output
136
Enable User IO Pdos
136
Number of Mapped RPDO Bytes
136
Number of Mapped TPDO Bytes
136
Reading Result with SDO/PDO
136
5.10.10.1.19 Reading Result Timeout
137
5.10.10.1.21 Enable Command Response Output
137
5.10.10.1.22 Command Response Timeout
137
Automatic Release after SDO Upload
137
5.10.10.1.27 Enable Diagnosis Output
138
Basic COB ID for PDO Reading Results
138
Inhibit Time
138
Number of Pdos
138
Transmission Type
138
Canopen Heartbeat Rate / Ms
139
Canopen Transmit Pdos 1-4
139
COB ID Emergency Obj
139
Diagnostics Timeout
139
Emergency Inhibit Time
139
Canopen Receive Pdos 1-4
140
5.10.11 Fieldbus Gateway
140
Profibus Proxy CDF600
140
Slave Address
140
Communication Protocol
141
Protocol/Output Format
141
Using PLC Output Bit 0
141
Using PLC Input Bit 0
142
Using PLC Input Bit 1
142
Using PLC Output Bit 1
142
Profibus/Devicenet/Profinet Gateway CMF400/CDM425
143
Serial Auxiliary Interface
143
Serial Host Interface
143
Profibus DP Gateway
144
Device ID
144
Operating Mode
144
Using Device ID as a Profibus Address
144
Devicenet Gateway
144
Using Device ID as a Devicenet Address
144
Data Transmission Rate
145
Useful Input Data Length
145
Useful Output Data Length
145
Profinet IO Gateway CDM425-PN
145
Default Gateway
145
Dhcp
145
IP Address
145
Station Name
145
Subnet Mask
145
Digital Inputs
146
Sensor / Result 1
146
Control
146
Logic
146
Sensitivity
146
Debouncing
147
Sensor / Result 2
147
Control
147
Logic
147
Sensitivity
147
Control
148
Debouncing
148
External Input 1
148
External Input 2
148
Logic
148
Sensitivity
148
Debouncing
149
5.10.13 Digital Outputs/Beeper
150
Active
150
Function (Off)
150
Output / Result 1
150
Control
151
Logic
151
Active
152
Function (Off)
152
Length
152
Output / Result 4
152
Output/Result 2
152
Logic
153
Active
154
Control
154
Length
154
Output / Result 3
154
Function (Off)
155
Logic
155
Active
156
Control
156
Length
156
Function (Off)
157
Logic
157
Active
158
Control
158
External Output 1
158
Function (Off)
158
Length
158
Function (Off)
159
Logic
159
Active
160
Control
160
External Output 2
160
Function (Off)
160
Length
160
Function (Off)
161
Logic
161
Beeper
162
Control
162
Length
162
Volume
162
6 Service
163
Operating Data
163
Device Information
163
Device Type
163
Manufacturer
163
Order Number
163
Serial Number
163
Software Version
163
Service Information
163
System Status
164
System Information
164
Reading Field/Scanning Frequency
164
7 Analysis
165
Event Monitor
165
Advertisement
SICK Lector 620 Operating Instructions Manual (6 pages)
Image-Based Code Reader
Brand:
SICK
| Category:
Card Reader
| Size: 0.53 MB
Advertisement
Related Products
SICK 6034031
SICK 6034024
SICK 6068091
SICK 6051597
SICK 6051599
SICK 6051603
SICK 6051598
SICK 6051600
SICK 6063619
SICK 6063623
SICK Categories
Accessories
Security Sensors
Measuring Instruments
Scanner
Barcode Reader
More SICK Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL