Samson TROVIS 5573-1 Mounting And Operating Instructions (164 pages)
Automation System and Heating and District Heating Controller
Brand:
Samson
| Category:
Temperature Controller
| Size: 1.93 MB
Table of Contents
Table of Contents
3
1 Safety Instructions
6
Disposal
6
2 Operation
7
Operating Controls
7
Rotary Pushbutton
7
Rotary Switch
7
Reading Information
8
Adapting the Trend-Viewer
10
Selecting Operating Modes
11
Setting the Time and Date
13
Setting the Times-Of-Use
15
Setting Special Times-Of-Use
17
Party Timer
17
Public Holidays
18
Vacations
19
Entering Day and Night Set Points
21
3 Start-Up
23
Setting the System Code Number
24
Activating and Deactivating Functions
25
Changing Parameters
27
Calibrating Sensors
28
Altering the Display Contrast
30
Changing the Display Language
30
Loading Default Setting
31
4 Manual Mode
32
5 Systems
33
6 Functions of the Heating Circuit
71
Weather-Compensated Control
71
Gradient Characteristic
72
Four-Point Characteristic
74
Fixed Set Point Control
75
Underfloor Heating/Drying of Jointless Floors
76
Outdoor Temperature for Continuous Day Mode
77
Buffer Tank Systems Anl 16.X
78
Summer Mode
79
Delayed Outdoor Temperature Adaptation
80
Remote Operation
80
Optimization
81
Flash Adaptation
82
Flash Adaptation Without Outdoor Sensor (Based on Room Temperature)
83
Adaptation
84
Cooling Control
84
7 Functions of the DHW Circuit
87
DHW Heating in the Storage Tank System
87
DHW Circuit Additionally Controlled by a Globe Valve
89
DHW Heating in the Storage Tank Charging System
90
DHW Heating in Instantaneous Heating System
92
Domestic Hot Water Heating with Solar System
93
Intermediate Heating
94
Parallel Pump Operation
94
Speed Control of Charging Pump
94
Circulation Pump During Storage Tank Charging
95
Priority Position
95
Reverse Control
95
Set-Back Operation
96
Forced Charging of DHW Storage Tank
97
Thermal Disinfection of DHW Storage Tank
97
8 System-Wide Functions
99
Automatic Summer/Standard Time Switchover
99
Frost Protection
99
Forced Pump Operation
100
Return Flow Temperature Limitation
100
Condensate Accumulation Control
101
Three-Step Control
102
On/Off Control
102
Continuous Control in Control Circuit RK1
103
Releasing a Control Circuit/Controller with Binary Input
103
Processing an External Demand in Control Circuit RK1
104
Creep Feed Rate Limitation with a Binary Input
105
Locking Manual Level
106
Locking the Rotary Switch
106
Feeder Pump Operation
106
External Demand for Heat Due to Insufficient Heat Supply
106
Entering Customized Key Number
107
9 Operational Faults
109
Error List
109
Sensor Failure
109
Temperature Monitoring
110
Error Status Register
110
Alarm Notification by Text Message
111
10 Communication
113
To Modem Communication Module
114
Communication Module
115
Description of Communication Parameter Settings
116
Meter Bus
117
Activating the Meter Bus
117
Flow Rate And/Or Capacity Limitation with Meter Bus
118
Memory Module
121
Data Logging
122
11 Installation
124
12 Electrical Connection
127
13 Appendix
132
Function Block Lists
132
Parameter Lists
144
Resistance Values
150
Technical Data
151
Customer Setting
152
Advertisement
Advertisement
Related Products
Samson TROVIS 5500
Samson trovis 5570
Samson TROVIS 5575
Samson TROVIS 5579
Samson TROVIS 5576
Samson TROVIS 5572
Samson TROVIS 5571
Samson TROVIS 5573
Samson TROVIS 5578-E
Samson TROVIS 5179
Samson Categories
Controller
Control Unit
Microphone
Valve Positioners
Microphone system
More Samson Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL