Installation
11 Installation
The controller can be fitted with a standard base or with a high housing base.
Dimensions in mm (W x H x D)
− Controller with standard base:
− Controller with high base:
The controller consists of the housing with the electronics and the back panel with the termi-
nals. It is suitable for panel, wall and top hat rail mounting (see Fig. 11).
Panel mounting
1. Undo the two screws (1).
2. Pull apart the controller housing and the base.
3. Make panel cut-out with the dimensions 138 x 92 mm (W x H).
4. Push the controller housing through the panel cut-out.
5. Tighten the two screws (2) to clamp the controller housing against the control panel.
6. Perform electric wiring on the base as described in section 12.
7. Remount the controller housing.
8. Fasten the two screws (1).
Wall mounting
1. Undo the two screws (1).
2. Pull apart the controller housing and the base.
3. If necessary, drill holes with the specified dimensions in the appropriate places. Fasten
the back panel with four screws.
4. Perform electric wiring on the base as described in section 12.
5. Remount the controller housing.
6. Fasten the two screws (1).
124
144 x 98 x 54
144 x 98 x 75
EB 5573-1 EN