Sign In
Upload
Manuals
Brands
Risco Manuals
Security System
ProSYS Plus
Risco ProSYS Plus Security System Manuals
Manuals and User Guides for Risco ProSYS Plus Security System. We have
3
Risco ProSYS Plus Security System manuals available for free PDF download: Installation And Programming Manual, Quick Installer's Manual, Quick User Manual
Risco ProSYS Plus Installation And Programming Manual (280 pages)
Brand:
Risco
| Category:
Security System
| Size: 5.72 MB
Table of Contents
Table of Contents
3
Introduction
9
System Architecture
10
System Capabilities
10
Main Features
13
Live Video Verification with Vupoint IP Cameras
13
Flexible Communication Options
14
Advanced Plug-In Communication Modules
14
Multiple Reporting Destinations
14
Cloud Communication
14
Monitoring, Notification, Operation and Control Via the RISCO Cloud
15
Enhanced Capabilities of Multi-Socket Communication Modules
16
Parallel Communication
17
Backup Communication
17
RISCO Bus Configurations
19
System Configuration Interfaces
19
Installation and Device Allocation Tools
19
Diagnostic Tests and Maintenance Features
19
Event Logging
20
Programmable Outputs
20
False Alarm Reduction Features
20
Home Automation
20
Safety Warnings and Precautions
21
Installation
22
Main Tasks for Initial System Setup
22
Step 1: Creating a Plan for Mounting the System
22
Main Panel Mounting Considerations - Wireless Systems
23
Central Mounting Location - Wireless Systems
24
RF Signal Loss Due to Common Building Materials
24
Step 2: Wiring, Settings, and Module Installations at the Main Panel
25
Main Panel Wiring Diagram
25
Power Supply, Ground, Telephone Wiring
26
Replacing the Main Panel PCB
27
Setting Main Panel DIP Switches and Jumpers
27
Main Panel DIP Switch Settings
27
Main Panel Jumper Setting
28
Describing Connectors & Ports on the Main Panel PCB
28
Installing Plug-In Communication and Audio Modules
29
Installing a GSM Module
29
Installing an IP Module
30
Installing the PSTN Modem Module
30
Installing an LRT Module
30
Installing the Voice Module
30
Installing the Listen-In & Speak Unit
31
Wiring Other Devices at the Terminal Block
32
Connecting a Wired Keypad
32
Connecting Auxiliary (12 V DC) Devices
32
Connecting the Bell / Loudspeaker
33
Connecting the Bell Tamper
33
Connecting the Box Tamper (Wall Tamper)
34
Connecting 4-Wire Smoke Detectors
34
Wiring Utility Outputs
35
Wiring Utility Output 1
35
Placing the JMP 2 (UO1) Jumper
35
Step 3: Bus Line Installations
36
Bus Line Wiring
36
Describing Bus Devices
36
Describing Bus Detectors and Their Connection Options
36
Typical Wired Expansion Modules Installed on RISCO Bus Lines
37
Describing Installer-Set ID Numbers for Bus Devices
38
ID Number Formats
39
Assigning ID Numbers (Setting DIP Switches) for Bus Devices
40
Installing Bus Devices
41
Installing Bus Detectors
41
Installing Wired Keypads
41
Connecting Multiple Bus Detectors Using Bus Zone Expanders
42
Installing Bus Zone Expanders
42
Installing Power Supply Expansion Modules
43
Installing Bus Sounders (Sirens)
44
Installing Utility Output Expansion Modules
44
Installing Wireless Expanders
44
Step 4: Connecting Relay Detectors
45
Installing Zone Expanders
46
Defining Zone Termination Resistance
46
Wiring Resistors for Zone Termination Resistance
47
Zone Termination Configuration Options
47
Step 5: Connecting the Backup Battery and Mounting the Main Panel
48
Connecting the Backup Battery
48
Mounting the Main Panel
48
System Initialization, Device Allocations & General System Configuration
49
Step 1: Describing Keypad Controls and Installer Menus
49
Describing Dynamic Keypad Menus
49
Designating Labels
49
Table of Keypad Buttons
49
Entering the Installer Programming Menu at Initial System Setup
50
Subsequently Accessing Installer Menus
50
Step 2: Powering-Up and Initializing the System
50
System Power-Up and Language Selection
50
Viewing Zones, Defining Partitions, and Setting the Time & Date
51
Viewing Zones, Defining Partitions and Setting Time/Date at Initialization
51
Keypad Timeout
52
Viewing & Updating Zones & Defining Partitions after Initialization
52
Step 3: Allocating and Configuring Installed Components
53
Auto-Setting Scan for Communication Modules & Bus Devices
53
Describing Auto-Setting Results
54
Performing a Bus Test
54
Manually Allocating & Configuring Communication Modules
55
Entering or Deleting a SIM Card PIN
55
GSM Modules
55
Defining APN Automatically and Manually
56
IP Modules
56
Long-Range Radio Transmitter Module
56
PSTN Modem Module
56
Setting Dynamic IP / Static IP
56
Manually Allocating and Configuring STU Adapter
57
Manually Allocating & Configuring Other Modules and Bus Devices
57
Wired Keypads
57
Utility Output Modules
58
Zone Expanders
58
Power Supply Modules
59
Proximity Key Readers
59
Wireless Expanders
59
Sounders (Sirens)
60
Voice Module
60
Bus Zone Expanders
61
Bus Zones (Bus Detectors)
61
Step 4: Allocating Wireless Zones
62
Allocating Wireless Expanders
62
Allocating Wireless Devices
62
Allocating Wireless Devices Via RF Transmission
62
Wireless Device RF Transmissions
63
Allocating Wireless Devices Via Code
64
Step 5: Basic Zone Configuration for All Zone Types
65
Defining Basic Parameters
65
Defining Zone Parameters Using the "One-By-One" Option
65
Describing Zone Information Displayed at the Keypad
65
Defining Zone Parameters Using the "By Category" Option
66
Defining Zone Termination Resistance Using the "Resistance" Option
67
Step 6: Advanced Zone Configuration for Bus Zones and Wireless Zones
68
Advanced Programming for Wireless Zones
68
Measuring Background Noise Level and Defining the Threshold Limit
69
Performing a Wireless Comm. Test for Measuring Signal Strength
70
Step 7: Configuring System Communication
71
Defining Primary Communication Channels & Parameters
71
Defining Communication with the Monitoring Station
72
Defining Monitoring Station Account Parameters
72
Enabling Monitoring Station Communication
72
Step 8: Configuring Cloud Connectivity
73
Enabling / Disabling Cloud Communication
73
Defining RISCO Cloud Connectivity
73
Step 9: Configuring Common System Parameters
74
Defining System Users
74
Defining User Codes
74
Changing the Default Grand Master Code
75
Changing the Default Installer Code
75
Defining Follow Me Destinations
75
Enabling Follow Me
75
Defining Follow Me Parameters
76
Defining System Timers
76
Defining All Additional Parameters
76
Installer Programming
77
Defining Parameters - Installer Programming Menu
77
System
78
Timers
78
Controls
82
Labels
97
Sounds
97
Settings
99
Automatic Clock
102
Service Information
102
Firmware Update
103
Zones
103
By Category
104
One-By-One
104
Parameters
104
Bus Zone: OPR12 (Watchout PIR)
118
Bus Zone: Iwise DT Grade 2
119
Bus Zone: (Industrial) Lunar /Bware/Iwise DT Grade 3
120
Bus Zone: Iwise QUAD Grade 2
121
Bus Zone: Iwise/Bware QUAD Grade 3
122
Bus Zone: ODT15 (Watchout DT)
123
Bus Zone: Watchin DT Grade 3
124
Bus Zone: Seismic
125
Wireless Zones: 1-Way and 2-Way Smoke
127
Wireless Zones: 2-Way PIR, Watchout and Wireless IR Beam
127
Wireless Zones: 2-Way Magnetic Contact Detector (X73)
128
Resistance
130
Testing
131
Cross Zones
132
Alarm Confirm
134
Outputs
135
Nothing
135
System
136
Partition
139
Zone
143
Code
144
Latch N/O & Latch N/C
145
Pattern of Operation for Utility Outputs
145
Pulse N/O & Pulse N/C
145
STU Testing
146
Codes
146
User
146
Grand Master
148
Code Length
149
Installer
149
Sub Installer
149
Communication
150
Method
150
Monitoring Station
163
Configuration SW
178
Follow Me
181
Cloud
187
Audio
190
Messages
190
Local Announcements
192
Install
193
Bus Devices
193
Wireless Devices
197
Devices
198
Keypad
199
Keyfob
200
Sounder
201
Power Supply
206
Proximity Key Reader
206
Exit
208
Exiting Installer Programming Menu
208
Exiting Installer Programming Menu after Initial System Programming
208
Subsequently Accessing & Exiting Installer Programming Menu
209
Restoring Manufacturer's Programming Defaults
209
Defining Parameters - Additional Installer Menus
210
Activities Menu
210
Follow Me Menu
210
View Menu
211
Clock Menu
212
Event Log Menu
212
Maintenance Menu
213
Macro Menu
214
Stand Alone Keyfob Menu
214
Testing the System
215
Installer Responsibilities for Assisting the Client
216
Appendix A: Technical Specification
217
Appendix B: Wiring
219
Appendix C: Installer Event Log Messages
221
Appendix D: Troubleshooting
230
Appendix E: Library Voice Messages
234
Appendix F: Monitoring Station Report Codes
235
Appendix G: Remote Software Upgrade
240
Appendix H: En50131 & En50136 Compliance
242
Appendix I: Prosys Plus Accessories
245
Appendix J: Installer Programming Maps
250
Advertisement
Risco ProSYS Plus Quick Installer's Manual (64 pages)
Brand:
Risco
| Category:
Security System
| Size: 1.99 MB
Table of Contents
Table of Contents
2
Getting Started
6
Main Steps for Initial System Setup
6
Important Safety Precautions
7
Installation
8
Step 1: Creating a Plan for Mounting the System
8
Main Panel Mounting Guidelines
8
Step 2: Wiring, Settings, and Module Installations at the Main Panel
8
Power Supply, Ground Wiring and Telephone Wiring
8
Main Panel Wiring Diagram
10
Replacing the Main Panel PCB
11
Setting Main Panel DIP Switches and Jumpers
11
Installing Plug-In Communication & Audio Modules
11
Installing a GSM Module
11
Installing a SIM Card
12
Installing an IP Module
12
Installing the PSTN Modem Module
12
Installing an LRT Module
12
Installing the Voice Module
12
Installing the Listen-In Unit
12
Wiring Other Devices at the Terminal Block
12
Installing a Wired Keypad
12
Connecting Auxiliary (12 V DC) Devices
13
Connecting the Bell / Loudspeaker
13
Connecting the Bell Tamper
14
Connecting the Box Tamper (Wall Tamper)
14
Connecting Utility Output 1
15
Placing the JMP 2 (UO1) Jumper
15
Step 3: Bus Line Installations
16
Bus Line Wiring
16
Describing Bus Devices
16
Describing Bus Detectors and Their Connection Options
16
Wired Expansion Modules Installed on RISCO Bus Lines
17
Describing Installer-Set ID Numbers for Bus Devices
18
ID Number Formats
19
Assigning ID Numbers (Setting DIP Switches) for Bus Devices
20
Installing Bus Devices
21
Installing Wired Keypads
21
Connecting Individual Bus Detectors to a Bus at the Main Panel
21
Connecting Multiple Bus Detectors Using Bus Zone Expanders
22
Step 4: Connecting Relay Detectors
23
Defining Zone Termination Resistance
24
Wiring Resistors for Zone Termination Resistance
24
Zone Termination Configuration Options
24
Step 5: Connecting the Backup Battery and Mounting the Main Panel
25
Connecting the Backup Battery
25
Mounting the Main Panel
25
System Initialization, Device Allocation, General System Configuration
26
Step 1: Working with the Keypad and Installer Menus
26
Describing Dynamic Keypad Menus
26
Table of Menu Navigational Keys
26
Designating Labels
26
Entering the Installer Programming Menu at Initial System Setup
27
Subsequently Accessing Installer Menus
27
Step 2: Powering-Up and Initializing the System
27
Initial System Power-Up and Language Selection
27
Viewing Zones, Defining Partitions, and Setting the Time & Date
28
Viewing Zones, Defining Partitions, and Setting Time/Date at Initialization
28
Viewing & Updating Zones and Defining Partitions after Initialization
29
Step 3: Allocating and Configuring Installed Components
30
Auto-Setting Allocation of Communication Modules and Bus Devices
30
Describing Auto-Setting Results
31
Performing a Bus Test
31
Manually Allocating & Configuring Communication Modules
32
GSM Modules
32
Entering or Deleting a SIM Card PIN
32
Defining APN Automatically and Manually
33
IP Modules
33
Setting Dynamic IP / Static IP
33
PSTN Modem Module
33
Long-Range Radio Transmitter Module
33
Manually Allocating & Configuring Other Modules and Bus Devices
34
Wired Keypads
34
Zone Expanders
35
Utility Output Modules
35
Power Supply Modules
35
Wireless Expanders
36
Proximity Key Readers
36
Voice Module
36
Sounders (Sirens)
37
Bus Zones (Bus Detectors)
37
Bus Zone Expanders
38
Step 4: Allocating Wireless Zones
39
Allocating Wireless Expanders
39
Allocating Wireless Devices
39
Sending Wireless Device RF Transmissions
40
Step 5: Basic Zone Configuration for All Zone Types
41
Defining Basic Parameters
41
Describing Zone Information Displayed at the Keypad
41
Defining Zone Parameters Using the "One-By-One" Option
42
Defining Zone Parameters Using the "By Category" Option
43
Defining Zone Termination Resistance Using the "Resistance" Option
43
Zone Termination Resistance Values (in Ohms)
44
Step 6: Advanced Zone Configuration for Bus Zones and Wireless Zones
44
Advanced Programming for Bus Zones
44
Advanced Programming for Wireless Zones
44
Measuring Background Noise Level and Defining Its Threshold Limit
45
Performing a Wireless Comm. Test for Measuring Signal Strength
46
Step 7: Configuring System Communication
47
Defining Primary Communication Channels & Parameters
47
Defining Communication with the Monitoring Station
48
Enabling Monitoring Station Communication
48
Defining Monitoring Station Account Parameters
48
Step 8: Configuring Cloud Connectivity
49
Enabling / Disabling Cloud Communication
49
Defining RISCO Cloud Connectivity
49
Step 9: Configuring Common System Parameters
50
Defining System Users
50
Defining User Codes
50
Changing the Default Installer Code
50
Changing the Default Grand Master Code
51
Defining Follow Me Destinations
51
Enabling Follow Me
51
Defining Follow Me Parameters
51
Defining System Timers
51
Installer Programming
52
Step 1: Defining Additional Parameters in the Installer Programming Menu
52
Step 2: Exiting Installer Programming Menu after Initial System Configuration
52
Step 3: Defining Parameters in Other Installer Menus
52
Testing the System
53
Installer Responsibilities for Assisting Clients
53
Technical Specification
54
Licensing Procedure
56
Risco ProSYS Plus Quick User Manual (8 pages)
Brand:
Risco
| Category:
Security System
| Size: 0.51 MB
Advertisement
Advertisement
Related Products
Risco ProSYS 16
RISCO ProSYS series
Risco ProSYS
Risco ProSYS KP
Risco ProSYS KPP
Risco ProSound
Risco Pro-24
Risco Wireless WatchOUT PIR 868
Risco Wireless WatchOUT PIR 433
Risco PAN08-2B
Risco Categories
Security Sensors
Security System
Keypad
Security Camera
Control Panel
More Risco Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL