Sign In
Upload
Manuals
Brands
LEYBOLD Manuals
Security Sensors
PhoeniXL300 Modul
LEYBOLD PhoeniXL300 Modul Manuals
Manuals and User Guides for LEYBOLD PhoeniXL300 Modul. We have
1
LEYBOLD PhoeniXL300 Modul manual available for free PDF download: Operating Instructions Manual
LEYBOLD PhoeniXL300 Modul Operating Instructions Manual (107 pages)
leak detector
Brand:
LEYBOLD
| Category:
Security Sensors
| Size: 2.25 MB
Table of Contents
Table of Contents
2
1 General Information
8
Notes on the Use of this Handbook
8
Safety Symbols
8
Indications
8
Symbols of Vacuum Technology
8
Definiton of Terms
9
Support from LEYBOLD Service
10
Introduction
11
Purpose
11
Technical Data Phoenixl 300
12
Technical Data
12
Electrical Data
12
Other Data
13
Ambient Conditions
13
Technical Data Phoenixl 300 Dry
13
Technical Data
13
Electrical Data
14
Technical Data Phoenixl 300 Modul
15
Technical Data
15
Electrical Data
15
Other Data
16
Ambient Conditions
16
Unpacking
16
Supplied Equipment
16
Accessories and Options
17
Sniffer Line SL300
17
Remote Control
18
Partial Flow System (Phoenixl Only)
18
2 Installation
19
Working Location
19
Electrical Connections
20
Mains Power
20
Connections for the Data Acquisition Systems
21
Option (Accessories)
21
Digital out (Control)
22
Digital in (Control 2)
22
Recorder
23
Rs232
23
Remote Control
24
Vaccum Connections
24
Inlet Port
24
Exhaust
24
Vent
24
Gas Ballast Connection
24
Connection of an External Pump
25
Modul )
25
Default Settings
25
3 First Operation Check
27
Needed Equipment
27
Description of the Initial Operation
27
Startup and Measure
27
Internal Calibration
28
Verification with an External Test Leak
29
Measure with a Test Object
29
Switch off
29
4 Description and Working Principle
30
Introduction
30
Vacuum System Phoenixl 300
30
Vacuum System Phoenixl
30
300 Modul
32
Vacuum System Phoenixl 300 Modul
32
Control Panel
34
LC Display
34
START Button
34
STOP Button
34
ZERO Button
35
MENU Button
36
Soft Keys
36
Numerical Entries
36
Vacuum Method
38
Partial Flow Method
39
Sniffer Mode
39
Controls on the Remote Control (Optional)
40
Displays on the Remote Control
42
5 Operation of the Phoenixl
43
Display
43
The Screen in Run-Up Mode
43
Display in Stand-By Mode
44
Gas Ballast/Purge
44
The Screen in Measurement Mode
44
Call for Calibration
45
Speaker Volume
45
Status Line in the Display
45
Measurement Mode with Bargraph
46
6 Description of the Menu
47
Main Menu
47
View
49
Scale Linear/Logarithmic
50
Display-Range Auto/Manual
51
Time Axis
51
Contrast
52
Background in Stand-By
52
Lower Display Limit
53
Mode
53
Trigger & Alarms
54
Trigger Level 1
55
Trigger Level 2
55
Trigger Level 3
55
Units
55
Volume
56
Alarm Delay
57
Audio Alarm Type
57
Pinpoint
58
Leak Rate Prop
58
Setpoint
58
Trigger Alarm
58
Calibration
59
Settings
60
Vacuum Settings
61
Automatic Purge
62
Vent Delay
62
Vacuum Ranges
63
Partial Flow Setup
64
Sniffer Factor
66
Machine Factor
66
Leak Rate Internal Test Leak
67
Filter & Background
67
Calculate Inlet Area Background
68
Background Suppression
68
Leak Rate Filter
68
Mass
69
Interfaces
69
Location of Control
69
Define Recorder Output
70
Rs232
71
Define PLC Outputs
71
Define PLC Inputs
72
Scaling Recorder Output
74
PLC Sample Rate
74
Miscellaneous
74
Time&Date
75
Language
75
Calibration Request
76
Service Interval Fore Pump
76
Service Interval Exhaust Oil Filter
76
Service Message Exhaust Oil Filter
77
Parameter Save / Load
77
Load Parameter Set
78
Save Parameter Set
78
Monitoring Functions
78
Pressure Limits for Vacuum Mode
78
Pressure Limits for Sniff Mode
79
Maximum Evacuation Time
80
Information
81
Service
81
Access Control
82
Access to CAL Function
82
Change Menu-PIN
83
Zero
83
7 Calibration
84
Introduction
84
The Calibration Routines
84
Internal Calibration
84
External Calibration
84
Factor of Calibration - Range of Values
86
8 Error and Warning Messages
87
Hints
87
List of Errors & Warnings
87
9 Maintenance
94
LEYBOLD Service
94
Maintenance Plan
94
Opening the Phoenixl
95
Exchanging the Filter Mats
96
Exchanging the Oil
96
Cleaning
97
Exchanging the Fuses
97
Exhaust Oil Filter
99
Turbo Molecular Pump
99
Calibrated Leak TL7
99
Tecnical Data
100
Factory Inspection
100
Appendix
101
Advertisement
Advertisement
Related Products
LEYBOLD PhoeniXL300 dry
LEYBOLD Phoenix Mobilis
Leybold RUVAC WS/WSU PFPE 251
Leybold RUVAC WS PFPE 1001
Leybold RUVAC WS PFPE 2001
LEYBOLD PENNINGVAC PTR 90 NS
LEYBOLD ECODRY plus 35
LEYBOLD ECODRY plus 45
LEYBOLD ECODRY plus 70
LEYBOLD Profibus
LEYBOLD Categories
Water Pump
Measuring Instruments
Transmitter
Controller
Media Converter
More LEYBOLD Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL