Sign In
Upload
Manuals
Brands
Fuji Electric Manuals
Recording Equipment
OPC-PRT
Fuji Electric OPC-PRT Manuals
Manuals and User Guides for Fuji Electric OPC-PRT. We have
1
Fuji Electric OPC-PRT manual available for free PDF download: Instruction Manual
Fuji Electric OPC-PRT Instruction Manual (116 pages)
Multiprotocol Ethernet Interface
Brand:
Fuji Electric
| Category:
Recording Equipment
| Size: 14.19 MB
Table of Contents
Safety Precautions
3
Installation and Wiring
4
Table of Contents
6
1 Pre-Operation Instructions
9
Product Overview
9
Features and Specifications
9
Unpacking and Product Confirmation
14
Shipment Confirmation
14
Component Overview
15
LED Indicators
16
Standard Leds
16
Network Status LED
16
Module Status LED
16
Ethernet Link/Activity Leds
16
2 Installation
17
Pre-Installation Instructions
17
Installation Procedure
17
3 Inverter Function Code Settings
22
Inverter Control-Related Settings
22
Inverter Reaction to Network Timeout Conditions
23
4 Function Code Numbering and Behavior
24
Register Numbers
24
Scanned Function Codes
27
Commonly Used Function Codes
27
5 Fuji Configuration Studio
29
Overview
29
General Object Editing Activities
31
Ethernet Settings
32
Authentication
32
Network Configuration
32
Internal Logic Settings
32
Fail-Safe Values
32
Overview
32
Timeout Time
33
Timeout Object Configuration
33
Fail-Safe Example
33
Discovery over Ethernet
34
Manage Device Parameters
34
Backup and Restore Parameters
35
Restore Factory Settings
36
Help
36
6 Embedded Web Server
37
Overview
37
Monitor Tab
37
Information Window
37
Function Code Group Selection List
38
Function Code List
38
Function Code List Filter
39
Radix Selection
39
Dashboard Tab
40
Information Window
40
Virtual Keypad
41
Gauge Window Navigation
42
Gauge Window Configuration
42
Submitting Changes
45
Customizing the Embedded Web Server
46
Customization Overview
46
Xtpro Overview
46
Xtpro Web Browser-Based Implementation
47
Xtpro HMI-Based Implementation
48
Xtpro Supported Commands
48
7 File System
49
Overview
49
USB with Windows Explorer
49
FTP with Windows Explorer
50
Loading New Web Server Content
50
8 Firmware
52
Overview
52
Update Procedure
52
9 Protocol-Specific Information
53
Modbus/Tcp
53
Overview
53
Holding & Input Registers
53
Coil & Discrete Input Mappings
53
Connection Timeout Options
54
Node Settings
55
Holding/Input Register Remap Settings
55
Ethernet/Ip
56
Overview
56
Server Settings
56
Connection Timeout Options
57
Generic Class 1 I/O Produced and Consumed Data Settings
57
Generic Class 1 (I/O) Connection Access
58
AC/DC Drive Profile Class 1 (I/O) Connection Access
58
Explicit Messaging Via Get/Set Attribute Single Services
60
Explicit Messaging Via Data Table Read/Write Services
61
Inverter Function Code Access Tag Format
61
Controllogix Examples: Setup
61
Controllogix Example: EDS Add-On Profile (AOP)
63
Controllogix Example: EDS Add-On Profile (AOP) Generic I/O Messaging
65
Controllogix Example: EDS Add-On Profile (AOP) AC/DC Drive Profile
66
Controllogix Example: I/O Messaging
68
Controllogix Example: Generic Default I/O Add-On Instruction
70
Controllogix Example: AC/DC Drive Profile Add-On Instruction
72
Controllogix Example: Read a Block of Function Codes
75
Controllogix Example: Reading and Writing MSG Instructions
79
Allen Bradley CSP (PCCC)
80
Overview
80
Explicit Messaging Via Read/Write Services
80
Inverter Function Code File Number Offset Format
80
SLC-5/05 Example: Read Function Codes
82
SLC-5/05 Example: Reading and Writing
87
Bacnet/Ip
88
Protocol Implementation Conformance Statement
88
Default Supported Objects
92
Default Supported Object Details
93
Server Settings
94
Node Settings
94
Device Object Settings
94
Bacnet Object Settings
94
Analog Input Object Settings
94
Analog Output Object Settings
95
Analog Value Object Settings
95
Binary Input Object Settings
95
Binary Output Object Settings
96
Binary Value Object Settings
97
Multi-State Input Object Settings
98
Multi-State Output Object Settings
98
Multi-State Value Object Settings
98
Profinet Io
99
Overview
99
Device Settings
99
Connection Timeout Options
99
Cyclic I/O Produced and Consumed Data Access Settings
99
Profidrive Profile
101
Profidrive Standard Telegram 1
101
Profidrive Control and Status Words
101
Profidrive Reference Speed Setpoint and Actual Speed
102
Profidrive State Diagram
103
Profidrive-Specific Parameters
104
Acyclic Data Access
104
TIA Portal (STEP 7) Hardware Configuration Example
104
Register the GSDML File
104
Add the Device to the Configuration
106
Select the IO Controller
106
Assign IO Module
106
Configure the Device Properties
107
Online Device Discovery and Configuration
108
Save the Configuration
109
GE Proficy Configuration Example
109
Register the GSDML File
109
Add the Device to the Configuration
111
Assign IO Module
111
Configure the Device Properties
112
Save the Configuration
113
10 Troubleshooting
114
Advertisement
Advertisement
Related Products
Fuji Electric OPC-PRT2
Fuji Electric OPC-G1-ETH
Fuji Electric Profibus OPC-F1-PDP
Fuji Electric OPC-VG1-DI
Fuji Electric OPC-VG1-PG
Fuji Electric OPC-VG1-PGo
Fuji Electric OPC-VG1-PMPG
Fuji Electric OPC-VG1-PMPGo
Fuji Electric OPC-VG1-TL
Fuji Electric OPC-E1-CCL
Fuji Electric Categories
Inverter
Air Conditioner
Measuring Instruments
Controller
Control Unit
More Fuji Electric Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL