Table of Contents
Table of Contents
3
1 Description
9
The Interference Sources of the Transients
9
Electrostatic Discharge ESD
9
Switched Inductance EFT (Burst)
9
Indirect Lightning SURGE
10
Voltage Interruptions, Dips
11
How ESD, EFT, SURGE DIPS Differ
11
Common Mode Disturbances in the Frequency Range 0 Hz to 150 Khz
12
Overview of the IMU4000 Test System
12
ESD - IMU4000 System Overview
14
EFT - IMU4000 System Overview
14
SURGE - IMU4000 System Overview
15
DIPS and Interruption - IMU4000 System Overview
15
Magnetic Fields - IMU4000 System Overview IEC 61000-4-8
16
Magnetic Fields - IMU4000 System Overview IEC 61000-4-9
16
Technical Data of the IMU4000
17
Electrostatic Discharges ESD Only Valid with EXT-TRA3000 E
17
Electric Fast Transient EFT EXT-IMU4000 F5
18
Coupling / De-Coupling Network EFT
18
Lightning and Switching Actions SURGE (IEC 61000-4-5 Ed.3)
20
Coupling / De-Coupling Network „CDN-SURGE
20
Power Voltage Limits on Direct Output Used Together with External SURGE CDN
21
Voltage Interruption and Variation with Internal Variac EXT-TRA3000 D-V
21
Interruption and Voltage Variation IEC 61000-4-11 Ed.2 with External Variac
22
DIPS Circuit in Accordance with IEC 61000-4-29 for D.C. Power Ports
22
Synchronisation of IMU4000 to Mains Frequencies
23
Measuring Circuit, Measuring Outputs
23
Trigger Output Levels
24
Control
24
Mechanical Dimensions
25
Power Consumption
25
Included Articles, Dimensions
25
Standard Accessories
26
2 Safety
27
Safety Standard
27
Climatic Conditions
27
Precautionary Measure During Use
28
Electromagnetic Compatibility
28
The Manual Is an Integral Part of the Equipment. Refer to the Manual
28
Sécurité
29
Normes de Sécurité
29
Conditions Climatiques
29
Mesures de Précaution Lors de L'utilisation
30
Compatibilité Électromagnétique
30
Le Manuel Fait Partie Intégrante de L'équipement
30
Sicherheit
31
Sicherheit Standard
31
Klimatische Bedingungen
31
Vorsichtsmassnahmen während dem Betrieb
32
Elektromagnetische Verträglichkeit
32
Dieses Manual ist Bestandteil von IMU4000 und dessen Testumgebung
32
3 Mechanical Structure
33
General
33
Impulse-Forming Networks
34
Measuring Circuit
35
Coupling / De-Coupling Network CDN
35
EUT Power Supply at DIPS
35
4 Control Panel
37
Front Panel of the IMU4000
37
Control Part
37
Operation Panel
39
Rear Panel of the IMU4000
41
5 Preparation for Operation
45
Attention, Refer to Manual
45
Operators and Service Personnel
45
Checks before Operation
45
Optical Verification of the IMU4000 Generators
45
Power Source Check
45
Connecting the IMU4000 Generator to the Power Line
45
EUT Power, Power Source for the EUT
45
EUT Power with Voltages Different from the Public Power Line (Variac)
47
EUT Power, Supply of the EUT with DC
48
SURGE Superimposing on DC
49
Hints for the Test Set up According to IEC Standards
50
Test Set up EFT
50
ESD Test Set up
51
Test Set up SURGE
52
Test Set-Up for Table Top Equipment
54
Practical Testing Sequence
55
6 Testing with the Imu4000
57
Operation of the Tester Via Touch Screen Monitor
57
General Information about the Touch Screen Monitor
57
Selecting the Parameter - Example CWG
57
The General Menu
61
General Menu "Setups
61
General Menu "Setup Linker
61
General Menu "Protocols
61
General Menu "Settings
62
General Menu "System
63
General Menu "Power
63
EUT - Power and EUT - Control
63
General Menu "Update
64
EMC Test Operation „RUN Mode
64
Example CWG Operation
65
Web Server
65
7 Maintenance and Servicing
67
Maintenance
67
Cleaning Front and Rearplate
67
Verification Versus Calibration
67
Verification Example IEC 61000-4-4
67
Calibration Example IEC 61000-4-4
67
Verification of the IMU4000 by the User
67
Eft
67
Esd
68
Surge
68
Interruption
68
Variation
68
Calibration of the IMU4000 by EMC PARTNER AG
69
Service of SPD Surge Protective Device
69
8 What Must be Done Following Failed Operation
71
Service; Repairs
71
Service Flowchart of IMU4000 System
72
Data Transfer Via UBS Stick
72
Spare Parts List
72
Check before You Contact the Service of EMCP
73
Fuses
73
Service Department of EMC PARTNER AG
73
9 Packaging and Transport
75
Packaging
75
Transport
75
10 Recycling / Disposal
77
Rohs Directive 2002/95/EG
77
WEEE Directive 2002/96/EG
77
Information for Dismantling
77
Parts Which Can be Recycled
77
Parts Which Cannot be Recycled
77
11 Accessories
79
TRA Accessories to IMU4000 Versions
79
Use of TRANSIENT Accessories
81
12 Remote Ports
83
General
83
Ethernet Port Setting on IMU4000
83
IP Address Setting on PC
83
Using Web Browser
84
Software "TEMA3000" for IMU4000
84
TEMA3000 Basic
84
13 Appendix And Corrections
87
Appendix
87
Definition of the EFT Waveform
87
Definition of the ESD Waveform
88
Definition of the SURGE Waveform
89
DIPS Specification
90
VARIATION Specification IEC 61000-4-11
91
VARIATION Specification IEC 61000-4-11 Ed.2
92
Correction
93
Glossary
95
Index
97
Advertisement
Advertisement
Related Products
EMC-PARTNER AVI3000
EMC-PARTNER CDN2000-06-25
EMC-PARTNER ESD3000
EMC-PARTNER EXTTRA3000 E
EMC-PARTNER TRA3000 C
EMC-PARTNER TRA3000 D
EMC-PARTNER TRA3000 F
EMC-PARTNER TRA3000 S
EMC-PARTNER TRA3000 V
EMC-PARTNER Categories
Test Equipment
Portable Generator
Conference System
Pulse Generator
More EMC-PARTNER Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL