PELLET STOVE ARITERM LILLA FRÖ Unpacking Remove the wood packaging. Detach the side panels and install the feet as follows: 1. Loosen the screw on the top of the side panel. 2. Lift the side panel straight up. 3. Unhook the side panel by carefully prying with a screwdriver...
Page 4
• The stove needs air in order to function, never close the supply air vent to the house. (This is not an issue for those who chose a solution with Ariterm Arrow; this ensures that the stove has air). •...
It is filled with pellets by opening the hatch under the stove’s top panel. The spacious hopper Ariterm Arrow ....... 11 means that the stove only needs to be refilled a maximum of twice a day.
PELLET STOVE ARITERM LILLA FRÖ 1.2 Components The top panel (1) is opened by lifting the front edge. Under this are the ash hatch (2) and the filler hatch (17) for the pellet hopper. The front (5) is opened to reach the door (7). The door is unlocked with the enclosed handle and it opens forwards, towards the floor.
PELLET STOVE ARITERM LILLA FRÖ 1.3 Technical data 1.4 Control panel Heating output HI / LO ........approx. 5 / 3 kW The control panel has a display and adjustment dial (see fig. 3): Pellet hopper .......... 30 litres (approx. 20 kg*) - The display shows the operating mode and the current temperature.
Page 8
PELLET STOVE ARITERM LILLA FRÖ Installing the control panel Removing the control panel 1. Install the wall mounting with 2 screws. 1. Slide the panel straight up. 2. Hook one corner of the panel onto the wall mounting. 2. Lift the panel straight out from the wall 3.
PELLET STOVE ARITERM LILLA FRÖ Main menu 1.5 Safety system Start? (Stop?) - Confirm by pressing once to start (stop). Stop T - Press to select and adjust desired stop temperature. The K6 stove is equipped with five independent safety systems.
PELLET STOVE ARITERM LILLA FRÖ 1.6.1 control process Otherwise the electronics manage all processes as follows: • Start • Low output operation (deactivated from the factory) Time Events Comments Time Events Comments 0 secs • Firing element on. After "Start".
We also recommend that a chimney fan is installed. 2.4 Ariterm Arrow Information about installation with Ariterm Arrow instead of a traditional chimney is available in a separate manual. See Arrow Wall fan Installation and Operation instructions.
PELLET STOVE ARITERM LILLA FRÖ 2.5 Electrical connection The back of the stove is equipped with a white black Light sensor orange 1.5 m long cable with plug, which must be black black black connected to a 230 V 50 Hz mains supply.
PELLET STOVE ARITERM LILLA FRÖ 3 Operation and maintenance 3.2 Ash removal The K6 stove is designed for a long service life, motors and other moving parts are of a very The amount of ash that build up in the burner varies depending partially on how the stove high quality.
PELLET STOVE ARITERM LILLA FRÖ 3.4 Sweeping The chimney must be checked for blockages if unused for a prolonged period. The chimney must be swept twice a year. The flue and its connection and the area 3.5 Hot air fan...
PELLET STOVE ARITERM LILLA FRÖ 3.6.1 Fault tracing and remedy Cause Action Cause Action Fault Fault • The cable is not connected. Connect to earthed 230 V socket. • The firing element does not Replace firing element. The stove does not Pellets do not ignite (no work.
Page 16
PELLET STOVE ARITERM LILLA FRÖ Error codes Cause Action Cause Action Error code Error code • Power failure. Check the electrical connection. • Incorrectly adjusted fuel and/or See Menu. Powfail. ErrorHI: air amount. The flame sensor has ("FeedHI" or "Fan HI") not detected a flame during high output.
PELLET STOVE ARITERM LILLA FRÖ 4 Dismantling 4.1 Burner 1. Open the door and remove the ash box. 2. Remove the four screws holding the burner flange to the stove wall (fig 10). 3. Pull the burner straight out until the cables connecting the burner to the control circuit board are visible.
4.5 Hot air fan Work is best carried out with both side hatches removed, but they can also be accessed For warranty issues Ariterm Sweden AB refers to our local Distributor. from one side or the other. 1. Remove the plug from the wall socket.
Clean Air Act requirements The Ariterm Lilla Fro pellet stove has been recommended as suitable for use in smoke control areas when burning wood pellets.
Page 20
PELLET STOVE ARITERM LILLA FRÖ If these instructions are not followed at installation, operation and maintenance, Ariterm Sweden AB’s applicable warranties are not binding. Ariterm reserves the right to make changes to components and specifications without prior notice. Ariterm Sweden AB Flottiljvägen 15, SE-392 41 Kalmar...