Page 3
PELLET STOVE KMP LILLA FRÖ Unpacking Remove the wood packaging. Detach the side panels and install the feet as follows: 1. Loosen the screw on the top of the side panel. 2. Lift the side panel straight up. 3. Unhook the side panel by carefully prying with a screwdriver... 4.
Page 4
PELLET STOVE KMP LILLA FRÖ Care and maintenance summary We recommend that you follow the care and maintenance instructions in order to obtain the best possible results from your stove. (This is not an issue for those who chose a solution with KMP Draft; this ensures that the stove has air).
PELLET STOVE KMP LILLA FRÖ 1.2 Components The top panel (1) is opened by lifting the front edge. Under this are the ash hatch (2) and the filler hatch (17) for the pellet hopper. The front (5) is opened to reach the door (7). The door is unlocked with the enclosed handle and it opens forwards, towards the floor.
PELLET STOVE KMP LILLA FRÖ 1.3 Technical data 1.4 Control panel ........approx. 5 / 3 kW The control panel has a display and adjustment dial (see fig. 3): Pellet hopper .......... 30 litres (approx. 20 kg*) - The display shows the operating mode and the current temperature. Explanatory text scrolls through the display every 5 seconds.
Page 8
PELLET STOVE KMP LILLA FRÖ Installing the control panel Removing the control panel 1. Slide the panel straight up. 2. Hook one corner of the panel onto the wall mounting. 2. Lift the panel straight out from the wall 3. Press the other corner of the panel onto the wall mounting. Connecting the control panel Connect the control panel in the modular connection on the side of the control...
PELLET STOVE KMP LILLA FRÖ Main menu 1.5 Safety system Start? (Stop?) - Confirm by pressing once to start (stop). Stop T - Press to select and adjust desired stop temperature. The K6 stove is equipped with five independent safety systems. Usermenu - Press for Usermenu.
PELLET STOVE KMP LILLA FRÖ 1.6.1 control process Otherwise the electronics manage all processes as follows: Time Events Comments Time Events Comments 0 secs After "Start". Low output scrolls through the The time depends on the set The firing element symbol illuminates. display.
PELLET STOVE KMP LILLA FRÖ 2 Installation 2.1 Positioning 2.2 Chimney The installation must meet all applicable European standards, local and national The regulations regarding chimneys can be found in the Building regulations. The most important regulations are: requirements. The stove should be located in a central position on the lower floor of the house to facili- may be 100˚C when the stove is running at full output.
PELLET STOVE KMP LILLA FRÖ 2.5 Electrical connection white black Light sensor orange The back of the stove is equipped with a black black black 1.5 m long cable with plug, which must brown black black Combustion fan black brown black mains supply.
PELLET STOVE KMP LILLA FRÖ 3 Operation and maintenance 3.2 Ash removal The amount of ash that build up in the burner varies depending partially on how the stove The K6 stove is designed for a long service life, motors and other moving parts are of a very high quality.
PELLET STOVE KMP LILLA FRÖ The chimney must be checked for blockages if unused for a prolonged period. The chimney must be swept twice a year. The flue and its connection and the area underneath the cleaning hatch must be cleaned at least once between the chimney 3.5 Hot air fan sweep’s visits.
PELLET STOVE KMP LILLA FRÖ 3.6.1 Fault tracing and remedy Cause Action Fault Cause Action Fault The cable is not connected. The firing element does not Replace firing element. The stove does not Pellets do not ignite (no work. start, green LED does smoke) No voltage at the socket.
Page 16
PELLET STOVE KMP LILLA FRÖ Error codes Cause Action Error code Cause Action Error code Check the electrical connection. See Menu. Powfail. air amount. The flame sensor has not detected a flame Check wiring and connections. during high output. Errign: Fill up the pellets.
PELLET STOVE KMP LILLA FRÖ 4 Dismantling 4.1 Burner 1. Open the door and remove the ash box. 2. Remove the four screws holding the burner flange to the stove wall (fig 10). 3. Pull the burner straight out until the cables connecting the burner to the control circuit board are visible.
5 Warranty Work is best carried out with both side hatches removed, but they can also be accessed For warranty issues Ariterm Sweden AB refers to our local Distributor. from one side or the other. 1. Remove the plug from the wall socket.
Page 20
If these instructions are not followed at installation, operation and maintenance, Ariterm Sweden AB’s applicable warranties are not binding. Ariterm reserves the right to make changes to components and specifications without prior notice. Ariterm Sweden AB Flottiljvägen 15, SE-392 41 Kalmar...