Contents General Features Features and Benefits Standard Equipment Optional Equipment General Data TUHMB060ACV3VB TUHMB080ACV3VB TUHMC100ACV4VB TUHMD120ACV5VB TDHMB060BCV3VB TDHMB080ACV3VB TDHMC100ACV4VB TDHMD120BCV5VB Performance Data 8-19 Venting Tables Electrical Data 21-24 Field Wiring 25-28 Dimensions 29-30 Pub. No. 22-1840-14...
Features and Benefits XC95m STANDARD EQUIPMENT • Stored fault code history in micropro- • Comfortlink II Communication cessor nonvolatile memory or 24 Volt control • Insulated blower door • Factory default is communication • Gasketed blower door mode • Attractive color accents •...
Maximum Vent Length Table VENT LENGTH TABLE - MODULATING FURNACE MAXIMUM TOTAL EQUIVALENT LENGTH IN FEET FOR VENT AND INLET ALTITUDE AIR (SEE NOTES) 2 INCH PIPE 2.5 INCH PIPE 3 or 4 INCH PIPE 0-7000 Feet NATURAL GAS PROPANE NATURAL GAS PROPANE NATURAL GAS...
Electrical Data TUHM Wiring Diagram CAUTION Label all wires prior to disconnection when servicing con- trols. Wiring errors can cause improper and dangerous opera- tion. Verify proper operation after servicing. Pub. No. 22-1840-14...
Page 22
Electrical Data TUHM Schematic Diagram CAUTION Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Pub. No. 22-1840-14...
Page 23
Electrical Data TDHM Wiring Diagram CAUTION Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Pub. No. 22-1840-14...
Page 24
Electrical Data TDHM Schematic Diagram CAUTION Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Pub. No. 22-1840-14...
NOTE: NOTE: The maximum total cable length for the entire Comfort BAYACCECOMM101 must used when Control communicating system is 500 ft. 18 AWG. The connecting an TFD whole house air cleaner to a maximum distance of any single cable from a trans- furnace in communicating mode.
Page 26
Communicating Indoor Unit with Communicating Comfort Control and 24VAC Single Stage Cooling 24 VAC Mode Indoor Unit with 24 VAC Comfort Control and 24VAC Single Stage Cooling Pub. No. 22-1840-14...
Page 27
24 VAC Mode Indoor Unit with 24 VAC Comfort Control and 24VAC 2-Stage or 2-Step Cooling 24 VAC Mode Indoor Unit with 24 VAC Comfort Control and 24VAC Single Stage Heat Pump Pub. No. 22-1840-14...
Page 28
24 VAC Mode Indoor Unit with 24 VAC Comfort Control and 24VAC 2-Stage or 2-Step Heat Pump Humidistat Hookup - 24 V Mode ONLY BK Jumper The factory installed jumper between "R" and "BK" on the circuit board must be cut if an optional humidistat is installed.
Page 32
Trane 6200 Troup Highway Tyler, TX 75707 Trane has a policy of continuous product and product data improvement and reserves the right to change www.trane.com design and specifications without notice.