Upflow/horizontal and dedicated downflow gas-fired, direct/non-direct vent, single stage / two stage condensing furnaces with high efficiency motor (128 pages)
Pub. No. 22-1682-05-0802 (EN) Contents Feature Summary Features and Benefits Standard Equipment Optional Equipment General Data TUY060R9V3V TUY080R9V3V TUY100R9V4V TUY120R9V5V Performance Data Electrical Data Field Wiring Dimensions...
*UY060R9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR AIRFLOW UNIT SIZE SETTING (TONS) (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON) (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON) (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON) (350 CFM/TON)
Page 8
Performance Data TUY080R9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR AIRFLOW DIP SWITCH SETTING UNIT SIZE SETTING (TONS) (See Notes) SW 1 (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON) (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON)
Page 9
TUY100R9V4V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR AIRFLOW UNIT SIZE SETTING (TONS) (See Notes) (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON) (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON) (350 CFM/TON) NORMAL (400 CFM/TON) HIGH...
Page 10
Performance Data TUY120R9V5V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR AIRFLOW DIP SWITCH SETTING UNIT SIZE SETTING SW 1 (TONS) (See Notes) (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON) (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON)
FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING TO 115 V 1 PH., 60 HZ., POWER SUPPLY PER LOCAL CODES HUM SEE NOTE 5 EAC SEE NOTE 5 FIELD WIRING DIAGRAM FOR 2 STAGE HEATING THERMOSTAT TO 115 V 1 PH., 60 HZ., POWER SUPPLY PER LOCAL CODES...
FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING/COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) FIELD WIRING DIAGRAM FOR 2 STAGE HEATING SINGLE STAGE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) Pub. No. 22-1682-05-0802 (EN) Field Wiring From Dwg. 21B341125 Rev. 1 From Dwg. 21B341124 Rev. 1...
Page 14
FIELD WIRING DIAGRAM FOR 2 STAGE HEATING TWO STAGE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) TO 115 V 1 PH., 60 HZ., POWER SUPPLY PER LOCAL CODES HUM SEE NOTE 5 EAC SEE NOTE 5 Field Wiring From Dwg. 21B341128 Rev. 0 Pub.
Page 16
Trane A business of American Standard Companies www.trane.com File No. PL-UN-FURN-TDD-D-1 3/98 Supersedes TDD-D-1 8/95 Since Trane has a policy of continuous product improvement, it reserves the right to change design and specifications without notice. P .I.