Upflow/horizontal two-stage condensing gas-fired furnace

Advertisement

TDD-D-1
Upflow/Horizontal
Two-stage Condensing
Gas-Fired Furnace
XV 90
TUY060,080,100,120R9V
Variable Speed Blower
Variable Speed Inducer
PUB. NO. 22-1682-05-0802 (EN)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 80 and is the answer not in the manual?

Questions and answers

Summary of Contents for Trane 80

  • Page 1 TDD-D-1 Upflow/Horizontal Two-stage Condensing Gas-Fired Furnace XV 90 TUY060,080,100,120R9V Variable Speed Blower Variable Speed Inducer PUB. NO. 22-1682-05-0802 (EN)
  • Page 2: General Features

    © 2002 American Standard Inc. All Rights Reserved General Features NATURAL GAS MODELS Central heating furnace designs are certified by the International Approval Services (IAS) for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards.
  • Page 3: Table Of Contents

    Pub. No. 22-1682-05-0802 (EN) Contents Feature Summary Features and Benefits Standard Equipment Optional Equipment General Data TUY060R9V3V TUY080R9V3V TUY100R9V4V TUY120R9V5V Performance Data Electrical Data Field Wiring Dimensions...
  • Page 4: Features And Benefits

    Features and Benefits XV 90 STANDARD EQUIPMENT • Variable speed indoor blower • Silicon Nitride Igniter with adaptive heat up • Variable speed induced draft blower • Direct/Non-Direct vent option • Fused 24 volt control circuit • Manual reset burner safety switches •...
  • Page 5: Optional Equipment

    Coil Enclosure (24-1/2" Wide Cabinets) ... BAYCLE2400C [ ] Side Filter Rack ... BAYFLTR200 [ ] Filter Kit/Horizontal Conversion TUY060, 080-R ... BAYFLTR203 [ ] Filter Kit/Horizontal Conversion TUY100-R ... BAYFLTR204 [ ] Filter Kit/Horizontal Conversion TUY120-R ... BAYFLTR205 [ ] Filter Accessory Kit Upflow 14.5"...
  • Page 6: General Data

    TUY-R9V PRODUCT SPECIFICATIONS1 MODEL TUY060R9V3V RATINGS2 1st Stage Input BTUH 39000 1st Stage Capacity BTUH (ICS)3 37000 2nd Stage Input BTUH 60000 2nd Stage Capacity BTUH (ICS)3 56000 AFUE (ICS) 93.0 Temp. Rise (Min.-Max.) °F. 35 - 65 BLOWER DRIVE DIRECT Dia.-Width (In.) 10 x 8...
  • Page 7: Performance Data

    *UY060R9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR AIRFLOW UNIT SIZE SETTING (TONS) (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON) (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON) (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON) (350 CFM/TON)
  • Page 8 Performance Data TUY080R9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR AIRFLOW DIP SWITCH SETTING UNIT SIZE SETTING (TONS) (See Notes) SW 1 (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON) (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON)
  • Page 9 TUY100R9V4V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR AIRFLOW UNIT SIZE SETTING (TONS) (See Notes) (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON) (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON) (350 CFM/TON) NORMAL (400 CFM/TON) HIGH...
  • Page 10 Performance Data TUY120R9V5V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR AIRFLOW DIP SWITCH SETTING UNIT SIZE SETTING SW 1 (TONS) (See Notes) (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON) (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON)
  • Page 11: Electrical Data

    Electrical Data SCHEMATIC DIAGRAMS FOR GAS FURNACES TUY060,080,100,120R9V-V LEGEND From Dwg. 21D341111 P03 Pub. No. 22-1682-05-0802 (EN)
  • Page 12: Field Wiring

    FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING TO 115 V 1 PH., 60 HZ., POWER SUPPLY PER LOCAL CODES HUM SEE NOTE 5 EAC SEE NOTE 5 FIELD WIRING DIAGRAM FOR 2 STAGE HEATING THERMOSTAT TO 115 V 1 PH., 60 HZ., POWER SUPPLY PER LOCAL CODES...
  • Page 13: Field Wiring Diagram For Single Stage Heating/Cooling

    FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING/COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) FIELD WIRING DIAGRAM FOR 2 STAGE HEATING SINGLE STAGE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) Pub. No. 22-1682-05-0802 (EN) Field Wiring From Dwg. 21B341125 Rev. 1 From Dwg. 21B341124 Rev. 1...
  • Page 14 FIELD WIRING DIAGRAM FOR 2 STAGE HEATING TWO STAGE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) TO 115 V 1 PH., 60 HZ., POWER SUPPLY PER LOCAL CODES HUM SEE NOTE 5 EAC SEE NOTE 5 Field Wiring From Dwg. 21B341128 Rev. 0 Pub.
  • Page 15: Dimensions

    Dimensions Pub. No. 22-1682-05-0802 (EN)
  • Page 16 Trane A business of American Standard Companies www.trane.com File No. PL-UN-FURN-TDD-D-1 3/98 Supersedes TDD-D-1 8/95 Since Trane has a policy of continuous product improvement, it reserves the right to change design and specifications without notice. P .I.