Electrical Connections And Cables; Wire Cross-Sections; Prefabricated Cables (Overview); Table 5-2: Cables For Connecting The Clv - SICK CLV 480 Operating Instructions Manual

Table of Contents

Advertisement

Chapter 5
CLV
Temperature
Type
range
0 to +40 °C
CLV
without
(+32 to
+104 °F)
heater
– 35 to +35 °C
CLV with
heater
(–31 to
+95 °F)

Table 5-2: Cables for connecting the CLV

5-2
Electrical installation
5.2

Electrical connections and cables

The electrical connections on the CLV consist of two 15-pin D Sub HD connections on the
housing, one plug, and one socket.
These connections are used to route the following interfaces:
Three serial data interfaces (host interface, CAN interfaces 1 and 2, terminal interface)
Six switching inputs (external reading pulse and multifunctional inputs)
Four switching outputs (for result status function, for connecting to a PLC for example)
Power supply
5.2.1

Wire cross-sections

CLV without heater:
All connections must be wired with copper cables with a minimum wire diameter of
0.15 mm
(approx. 26 AWG)!
2
CLV with heater:
Connect the power supply terminals (Pin 1/Pin 5) using copper wires with a minimum
cross-section of 0.75 mm
5.2.2

Prefabricated cables (overview)

Connection
Optional
module
cable
AMV/S 60
2 x No. 2 020 302 or
1 x No. 2 020 307
BMV/BMH 10
1 x No. 2 020 307 or
Bus Connec-
tion Module
1 x No. 2 021 298
AMV 30-071
2 x No. 2 020 302 or
1 x No. 2 020 307
BMS 20
1 x No. 2 020 264 +
Interbus-S
1 x No. 2 020 265 or
1 x No. 2 020 308
Non-Sick
1 x No. 2 020 303 +
Power pack
1 x No. 2 020 264 or
1 x No. 2 020 981 or
1 x No. 2 021 267
AMV 100
1 x No. 2 021 298 or
1 x No. 2 021 689 or
1 x No. 2 027 543
AMV 200
2 x No. 2 021 298 or
2 x No. 2 021 689 or
2 x No. 2 027 543
Non-Sick
1 x No. 2 021 267
Power pack
For technical data on the cables, see
ries and plug cover, Page
© SICK AG · Division Auto Ident · Germany · All rights reserved
(approx. 20 AWG) at a maximum length of 10 m (32.8 ft)!
2
Length
3 m (9.84 in)
3 m (9.84 in)
3 m (9.84 in)
3 m (9.84 in)
3 m (9.84 in)
3 m (9.84 in)
3 m (9.84 in)
3 m (9.84 in)
3 m (9.84 in)
3 m (9.84 in)
3 m (9.84 in)
3 m (9.84 in)
3 m (9.84 in)
3 m (9.84 in)
3 m (9.84 in)
3 m (9.84 in)
3 m (9.84 in)
3 m (9.84 in)
3 m (9.84 in)
3 m (9.84 in)
Chapter 10.12.4 Cables, external parameter memo-
10-53.
Operating Instructions
CLV 480 Bar Code Scanner
Type
Connecting cable (plug/socket)
Ext. parameter memory with 2 cables
(plug/socket)
Ext. parameter memory with 2 cables
(plug/socket)
Connector cover to connector cover
Connecting cable (plug/socket)
Ext. parameter memory with 2 cables
(plug/socket)
Connecting cable with plug/open end
Connecting cable with plug/socket
Ext. parameter memory with 2 cables
(plug/open end)
Connecting cable with socket/open end
Connecting cable with plug/open end
Ext. parameter memory with 2 cables
(open ends)
Connector cover with 2 cables (open ends)
Connector cover to connector cover
Ext. parameter memory to connector cover
Ext. parameter memory to connector cover
with wires for CAN interface 1 (IN/OUT)
Connector cover to connector cover
Ext. parameter memory to connector cover
Ext. parameter memory to connector cover
with wires for CAN interface 1 (IN/OUT)
Connector cover with 2 cables (open ends)