Troubleshooting - Martin Jem ZR25 User Manual

Hide thumbs Also See for Jem ZR25:
Table of Contents

Advertisement

Troubleshooting

Problem
Machine will not produce fog
when control panel set to
CONTINUOUS or fog button
pressed
Machine can be fired from
control panel, but not by
DMX controller
Fog output is weak
Wet, greasy, non-uniform
fog output, fluid drips or
spits from nozzle, or very
loud noise when firing
machine
Machine appears dead
Machine causes DMX errors
to occur on other units when
connected to a DMX system
Loss of control from remote
22
Probable cause(s)
Machine not at operating
temperature
FOG option set to 0
Machine in timer mode and
TIMER ON set to 0
DMX signal present
DMX address setting
incorrect
Poor connection in DMX line
LINK menu is set to SEND
Machine requires priming
Incompatible fog fluid
Mains fuse blown
No power at AC cable inlet
LINK menu is set to SEND
Communication issue
between remote and
machine
Troubleshooting
Suggested remedy
Wait until HEAT message no
longer shown
Increase setting
Increase setting
Disconnect or turn off DMX
controller
Change DMX address (page
16)
Check DMX cables and
connections
Set LINK menu to RECEIVE
Use PRIME option to prime
the machine (page 17)
Use approved fluid!
Replace fuse (page 21)
Check power cable and
circuit breaker
Set LINK menu to RECEIVE
Check cable connection
between remote and
machine