INFINITY 26i and HD50i SERVICE MANUAL Infinity High Capacity Continuous Flow Gas Hot Water System...
Page 2
Quality System Standard ISO 9001 - 1994 The Design, Development, and Manufacture of Gas Water Heating Appliances done under Rinnai’s Quality Management System is certified under the Quality Management System Standard ISO 9001. Registration Number JQ0003D Registered since: February 1994...
Page 3
Produced by Rinnai Technical Services Department August 2004 - Issue 1. No portion or part of this manual may be copied without prior permission from Rinnai U.K. Rinnai U.K. reserves the right to make modifications and change specifications without notice.
Features • The Infinity 26i and HD50i NEVER RUN OUT of hot water. Whilst electricity, water and gas supplies are connected, hot water is available whenever hot water taps are open. • Built into the main micro-processor is the facility to LIMIT THE MAXIMUM TEMPERATURE of the hot water supplied.
Note 1: The default factory setting is 55ºC for the Infinity26i, and 65°C for HD50i. The unit can be ordered from Rinnai to be pre-set to any of the other temperatures listed. The unit can be pre-set to any of the temperatures listed by a suitably qualified person.
Controllers are supplied with 15 m of electrical cable. The cable wires for connection to the appliance are fitted with spade terminals. Extension cables are available from Rinnai. Alternatively, a two core sheathed (double insulated) flex with minimum cross-sectional area of 0.5 mm² can be used. Maximum cable length is 50 m.
12. Dip Switch Settings WARNING: Dip Switch settings must only be changed by an authorised person. Dip Switch Settings for Infinity 26i and HD50i Dip Switch Settings for Infinity 26i and HD50i Note: Unit must be specially converted for delivery at 85 C for REU-V2632FFUC models only.
If normal, proceed to Faulty: Replace PCB. b.) Disconnect connector (J ) and measure resistance between both terminals of the sparker. Normal: 1M If not sparking, adjust or replace ignition plug. Faulty: Replace Sparker. Infinity 26i and HD50i - 24 - Issue 1...
Page 30
If normal,, proceed to Faulty: Replace Solenoid Valve 2. Measure voltage between Blue and Black of Solenoid Valve connector. Normal: DC80~100V If normal, proceed to Thermal fuse Circuit. Faulty: Replace PCB. Infinity 26i and HD50i - 25 - Issue 1...
Page 31
Normal: Voltage AC5~150V If normal, replaced PCB Faulty: Replace Flame Rod. c.) Check if the Flame Rod is securely fitted. Normal: replace the PCB Faulty: Adjust the fitting of the Flame Rod Infinity 26i and HD50i - 26 - Issue 1...
Page 32
Measure voltage between Yellow - Black of relay connector (B Normal: DC 4~7V If normal, proceed to 2). Faulty: Replace water flow sensor. Note: For controller readout of water flow whilst operational refer maintenance monitor. (Chapter 17 No. 1). Infinity 26i and HD50i - 27 - Issu e 1...
Page 33
Circuit break: Resistance >1M Short circuit: Resistance > 1 Normal: Check Heat exchanger outlet thermistor Faulty: Replace heat exchanger outlet thermistor. Note: For controller readout of thermistor temperature whilst operational refer maintenance monitor. Infinity 26i and HD50i - 28 - Issu e 1...
Page 34
Measure the voltage between red and red on the transmission connector (F Normal: AC207~264V If normal proceed to b.). Faulty: Check if the voltage on fuse terminals is 207~264V. Infinity 26i and HD50i - 29 - Issu e 1...
Faulty: Because normal voltage is not given due a short circuit, despite the PCB being in normal state, check Water Flow Servo circuit. If solution is not given from the above replace PCB. Infinity 26i and HD50i - 30 - Issue 1...
17. The maintenance number will be shown in the Water Temperature display. 18. Data will be shown in the Clock display. 19. To select the required maintenance number, press the Water Temperature "UP" and "DOWN" buttons. Note: Infinity 26i and HD50i use Maintenance Numbers 1-12. Display Monitor Contents Contents Units...
Page 44
Anti Frost Heater Installation Anti Frost Heaters come as standard on ALL Rinnai Infinity and Heavy Duty water heaters sold in the UK. They will not need to be installed on site. The diagram on the following page shows where the elements are located.