Rinnai Infinity 26 Operation & Installation Manual

Rinnai Infinity 26 Operation & Installation Manual

Gas continuous flow water heater
Table of Contents

Advertisement

Models:
Infinity 26 Touch (REU-AM2626WDL)
Infinity 26
Infinity 20
Infinity 16
Infinity 12
Gas Continuous Flow Water Heater
Operation & Installation Manual
(REU-AM2626WD)
(REU-AM2024WD)
(REU-AM1620WD)
(REU-AM1220WD)
Infinity Enviro 26
Infinity Enviro 16
B26
B20
B16
(REU-E2626W)
(REU-E1620W)
(REU-A2626WB)
(REU-A2024WB)
(REU-A1620WB)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Infinity 26 and is the answer not in the manual?

Questions and answers

Sarah Eldridge-Smith
January 18, 2025

Hi there I have a rinnai rea+a2626wb+50+ak hot water service but I’m currently in a blackout. Is there anyway to start the hot water service without electricity? Thanks

User image 678b1c170575a
1 comments:
Mr. Anderson
February 3, 2025

No, the Rinnai Infinity 26 hot water service cannot operate without electricity during a blackout. However, it can be powered temporarily using a UPS (Uninterruptible Power Supply).

This answer is automatically generated

Summary of Contents for Rinnai Infinity 26

  • Page 1 Models: Infinity 26 Touch (REU-AM2626WDL) Infinity Enviro 26 (REU-E2626W) Infinity 26 (REU-AM2626WD) Infinity Enviro 16 (REU-E1620W) Infinity 20 (REU-AM2024WD) (REU-A2626WB) Infinity 16 (REU-AM1620WD) (REU-A2024WB) Infinity 12 (REU-AM1220WD) (REU-A1620WB) Gas Continuous Flow Water Heater Operation & Installation Manual...
  • Page 2 Congratulations on the purchase of your Rinnai Gas Continuous Flow Water Heater. We trust you will have many years of comfort and enjoyment from your appliance. BEFORE USING THIS APPLIANCE Before proceeding with the operation or installation read this manual thoroughly and gain a full IMPORTANT understanding of the appliance, to ensure safe and correct use.
  • Page 3: Table Of Contents

    Operational Safety Information ����������������������������������������������������������������������������������������������������������������������������������������� 5 Features & Benefits ................................7 Water Temperature Control Maximum Delivery Temperatures ............................8 Operation Without Water Controllers ..........................8 Rinnai Water Controllers ..............................8 Location ����������������������������������������������������������������������������������������������������������������������������������������������������������������������������� 8 Water Resistance �������������������������������������������������������������������������������������������������������������������������������������������������������������� 8 Temperature Control ��������������������������������������������������������������������������������������������������������������������������������������������������������� 9 Water Controller Configurations ���������������������������������������������������������������������������������������������������������������������������������������� 9 Universal Water Controller (MC-601Q) Operation ......................
  • Page 4: Warnings & Important Information

    It may also be used to alert against unsafe practices. REGULATORY INFORMATION Your Rinnai gas continuous flow water heater has been certified by the Australian Gas Association. WARNING The A.G.A. Certification Number is shown on the data plate.
  • Page 5: Operational Safety Information

    50°C being selected. the water to go cold. Someone maybe in the middle of When 'priority' is returned to Water Controllers other having a shower or filling a bath. than the Kitchen the temperature will be 42°C. Rinnai HW_CF OIM...
  • Page 6 WARNINGS & IMPORTANT INFORMATION The range of Rinnai gas continuous flow water heaters referred to in this manual are incompatible with solar water heating systems. A dedicated range of solar compatible continuous flow water heaters is available from Rinnai. IMPORTANT If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  • Page 7: Features & Benefits

    Congratulations on purchasing the latest technology temperature controlled Rinnai gas continuous flow water heater. • The Rinnai gas continuous flow water heater products NEVER RUN OUT of hot water. Whilst electricity, water and gas supplies are connected, hot water is available whenever hot water taps are open. •...
  • Page 8: Water Temperature Control

    OPERATION WITHOUT WATER CONTROLLERS Rinnai gas continuous flow water heater products do not use a pilot light. When installed and operated without water controllers, the opening of any hot water tap will automatically start the appliance. Once water is flowing through the appliance the burner will be ignited by electronic ignition and water will be delivered at the maximum temperature that the unit is capable of delivering.
  • Page 9: Temperature Control

    A up to a maximum of TWO BC-100V water controllers can be installed. • The FOURTH water controller in any installation MUST BE a MC-601Q or a MC-503RC-S. To find out more about the full range of Rinnai water controller models, contact Rinnai or visit: www.rinnai.com.au. Rinnai HW_CF OIM...
  • Page 10: Universal Water Controller (Mc-601Q) Operation

    Water Controller Combinations & Configurations Wireless, Universal and Deluxe water controllers can be combined, Refer to "Water Controller Configurations" on page 9 to confirm the maximum number and combination of controllers that can be fitted. Rinnai HW_CF OIM...
  • Page 11: Smartstart Pre-Heat System

    WATER TEMPERATURE CONTROL SMARTSTART PRE-HEAT SYSTEM The “Preheat” function works in conjunction with various Rinnai water heater models when the separately installed and optional Rinnai “Smartstart®” module is installed. Preheat Button Used to start and stop Smartstart preheater Preheat Indicator...
  • Page 12: Trouble Shooting

    ERROR CODES Your Rinnai gas continuous flow water heaters has a self diagnostic capability. If a fault occurs, an Error Code will flash on the digital monitor of your water controllers or on the status monitor * on the front cover of the water heater.
  • Page 13: No Power Display Wireless Water Controller (When Fitted)

    Rinnai has a Service and Spare Parts network with personnel who are fully trained and equipped to give the best service on your Rinnai appliance. If your appliance requires service, please call our National Help Line or the Hot Water Service Line (contact numbers for which are on the back cover of this manual).
  • Page 14 This page intentionally blank. Rinnai HW_CF OIM...
  • Page 15 This page intentionally blank. Rinnai HW_CF OIM...
  • Page 16: Installation Table Of Contents

    Connecting Communication Cable(s) With 'Ezi connect' (REU-A / REU-AM) ���������������������������������������������������������������� 27 Connecting Communication Cables to Mini-Plug (REU-E) ��������������������������������������������������������������������������������������������� 27 Connecting Communication Cables to PCB (REU-E) ����������������������������������������������������������������������������������������������������� 28 Universal Water Controller (MC-601Q) Installation ......................28 Additional Programming & Activation Requirements ������������������������������������������������������������������������������������������������������� 29 Rinnai HW_CF OIM...
  • Page 17 Specifications Table 1. Appliance Dimensions ............................32 Diagram 1. Dimensions ..............................33 Table 2. Supply, Flow rates, Weights & Service Connections ..................34 Table 3. Maximum Delivery Temperatures ........................34 Table 4. Other Accessories ............................... 34 Contacts Rinnai HW_CF OIM...
  • Page 18: General Installation Information

    For installations where the distance between the water heater and the outlets is considerable, a flow and return system or the Rinnai Smartstart® system can be used which minimise the waiting time for hot water delivery.
  • Page 19: Service Connection Points

    Table 2 are exceeded. To achieve the rated flow, the ‘Minimum’ water supply pressures in Table 2 must be supplied. The water heaters will operate at lower pressures but will not achieve the rated flow. Contact Rinnai for ‘gravity fed’ or ‘low pressure’ installations.
  • Page 20: Hot Water Delivery Temperature

    Temperature Limiting Device. Installations without a Temperature Limiting Device are shown in Diagram 1 below. If you are unsure about your local regulations contact your regulating authority or Rinnai. If the appliance is NOT marked to state that it delivers water not exceeding 50°C, or your local regulations require installation with a Temperature Limiting Device then install the appliance in accordance with Diagram 2 below.
  • Page 21: Flueing

    For minimum clearances not addressed above acceptance should be obtained from the Technical Regulator. Minimum clearances d and e also apply to any combustion air intake openings of appliances. FIGURE 6.2 (in-part) LOCATION OF FLUE TERMINALS OF BALANCED FLUE, ROOM-SEALED, FAN-ASSISTED OR OUTDOOR APPLIANCES Rinnai HW_CF OIM...
  • Page 22: Horizontal Obstructions

    For correct operation of Rinnai external gas continuous flow water heaters such a building structure MUST ‘obstruct’ the full front cover height of the appliance (for appliance dimensions, refer to "Table 1. Appliance Dimensions" on page 32), or extend vertically above and below the front cover as shown below.
  • Page 23: Neutraliser Tank & Drain

    75 mm or higher than 300 mm above a gravel pit not less than 100 mm in diameter in a paved surface. (e) Where discharging over a tundish or gully trap, drain lines shall have an air gap of a size at least twice the diameter of the drain line. Rinnai HW_HD_CF OIM...
  • Page 24: Interconnection Of Condensate / Neutraliser Drain Lines

    300 mm in length. It shall discharge into a tundish through an air gap of not less than 75 mm and not more than 150 mm measured from the outlet of the drain pipe to the rim of the tundish. Rinnai HW_HD_CF OIM...
  • Page 25: Water Controller Installation

    Up to TWO deluxe bathroom water controllers can be installed. • The FOURTH water controller in any installation MUST BE a wireless or a universal water controller. To find out more about the full range of Rinnai water controller models, contact Rinnai or visit: www.rinnai.com.au. Rinnai HW_CF OIM...
  • Page 26: Location

    Wired water controllers operate at an extra low voltage (12 Volts DC) which is supplied from the water heater, a 10 metre long communications cable is supplied for connection to the water heater. ONLY Rinnai supplied communication cables may be used.
  • Page 27: Connecting Communication Cable(S) With 'Ezi Connect' (Reu-A / Reu-Am)

    Controllers are not polarity sensitive, however to avoid confusion it is recommended that like coloured wires be terminated together. Communications Cable Electrical Connectors MC-91Q, MC-601Q, BC-100V (Supplied with Water Controllers) Communications Cable MC-100V, MC-503RC-M Pre-wired Mini-Plug (Supplied) Rinnai HW_CF OIM...
  • Page 28: Connecting Communication Cables To Pcb (Reu-E)

    Fix the water controller to the wall using the appropriate fixings (Fig. 3). Remove protective film from the water controller face and replace the cover plates (Fig. 4). Rinnai HW_CF OIM...
  • Page 29: Additional Programming & Activation Requirements

    If the water controller in the kitchen is swapped with another water controller (for example, the water controller fitted in a bathroom), repeat STEP 1 for the water controller moved from the kitchen to the bathroom. Then perform STEP 1 for the water controller moved from bathroom to the kitchen. Rinnai HW_CF OIM...
  • Page 30: Commissioning

    13. After testing is completed, explain to the householder the functions and operation of the water heater and water controllers (if fitted). Ensure the "Installation Record" on page 31 is filled in and that this booklet is handed to the customer. Reminding the customer to complete the Warranty Card and forward to Rinnai. DELIVERY TEMPERATURE 50°C Compliant Models...
  • Page 31: Gas Pressure Setting

    A commissioning check list is provided on the appliance front cover to enable the installer to step through the correct commissioning procedure when installing a Rinnai gas continuous flow water heater. The check list can also assist the installer to identify potential installation errors that may prevent the appliance from operating correctly.
  • Page 32: Specifications

    Gas Connection Length (from base) Cold Connection Length (from base) Hot Connection Length (from base) Condensate outlet (from base) * Measurement is from the left of the centre line Vertical Mounting Hole Centres Cable Access Hole Size Ø20 Position Centre Rinnai HW_CF OIM...
  • Page 33: Diagram 1. Dimensions

    SPECIFICATIONS DIAGRAM 1. DIMENSIONS Infinity Series Infinity Enviro Series B Series MC-601Q Drawings are not to scale Rinnai HW_CF OIM...
  • Page 34 Non - 50°C Compliant - Models 50°C Compliant - Models TABLE 4. OTHER ACCESSORIES Where the accessory compatibility information is not specified, please contact Rinnai for details about our full accessory range and their model suitability, or visit: www.rinnai.com.au. REU Series...
  • Page 35 NOTES Rinnai HW_CF OIM...
  • Page 36: Contacts

    *Cost of a local call higher from mobile or public phones. For further information visit www.rinnai.com.au or email enquiry@rinnai.com.au Rinnai has a Service and Spare Parts network with personnel who are fully trained and equipped to give the best service on your Rinnai appliance. If your U340—1330X01(00)

Table of Contents

Save PDF