MMB Messages
C8A90602
SMI2 lane degraded
Meaning:
Lane degradation was detected in the interface between CPU/Memory Scale-up Controller with Memory
Buffer.
Corrective action:
The target CPU, SB, Memory Scale-up Board or Mezzanine must be replaced. Contact your sales
representative or a field engineer.
Severity:
Warning

2.1.16 PCI Express related

Messages related to PCI Express are listed below.
C76F01FF
Failed
Meaning:
A clock error has occurred.
Corrective action:
SB must be replaced. Contact your sales representative or a field engineer.
Severity:
Error
C8A10410
PCIe SW Upstream Data link Protocol Error
Meaning:
An error has occurred in the A switch port error has occurred.
Corrective action:
The target SB, IOU, or PCI_Box must be replaced. Contact your sales representative or a field engineer.
Severity:
Error
C8A10412
PCIe SW Upstream Poisoned TLP
Meaning:
A switch port error has occurred.
Corrective action:
The target SB, IOU, or PCI_Box must be replaced. Contact your sales representative or a field engineer.
Severity:
Error
C8A10413
PCIe SW Upstream Flow Control Protocol Error
Meaning:
A switch port error has occurred.
Corrective action:
The target SB, IOU, or PCI_Box must be replaced. Contact your sales representative or a field engineer.
Severity:
Error
C8A10414
PCIe SW Upstream Completion Timeout
Meaning:
A switch port error has occurred.
Corrective action:
The target SB, IOU, or PCI_Box must be replaced. Contact your sales representative or a field engineer.
Severity:
Error