Item
Power supply rating
Average thermal (BTU per hour)
Max thermal (BTU per hour)
Max power usage
Other thermal:
• Temperature range (operational): 10° to 35° C (50° to 95° F)
• Maximum rate of temperature change per hour (operational) 10° C (18° F)
• Temperature range (storage): -10° to 45° C (14° to 113° F)
• Maximum rate of temperature change per hour (storage) 15° C (27° F)
• Temperature range (transit): -20° to 60° C (-4° to 140° F)
• Maximum rate of temperature change per hour (transit) 20° C (36° F)
Humidity:
• Operational: 20-80%
• Storage: 10-90%
• Transit: 5-95%
Noise: A-weighted Sound Power Level, Lwa (db re 1pW):
• Typical: 71
• Max: 81
Shock and vibration:
• Optional random vibration: 10 to 350 Hz @ 0.18 Grms
• Non-operational sinusoidal vibration: 60 to 350 Hz: @ 1g
• Non-operational shock: 3g 11ms, half sine
Packaged transport specification:
• Drops from 356mm and 508mm as per ASTM D5276
• Vibration at up to 0.53 Grms as per ASTM D4728
Altitude:
• Maximum of 2000 meters
Approvals:
• Europe: CE, RoHS (6) & WEEE compliant
• EMC: EN55022, FCC & VCCI, all class A. EN55024
• Safety: CSA/UL 60950-1, EN60950-1
Hitachi NAS Platform 3080/3090 G2 Hardware Reference Guide
Models 3080 G2 and 3090 G2
230 VAC: 1.1A to 1.4A
450W
853
1057
310W
System overview
33