SCD-XE800
Note 1: According to the following procedures when you ship it
(Return it to the customer).
1. SERVICE MODE (1) of step 6 and 7
(EEPROM clearness)
2. COLD RESET
When the service mode is operated, the following, remote com-
mander is necessary.
(The service mode cannot be operated by remote commander to
which this machine is attached)
Remote commander (RM-ASP004): Part No. 1-479-272-21
Note: Above-mentioned remote commander is one example. If it is the
one printed under a remote commander as "DVD", any remote com-
mander can be operated.
COLD RESET
The cold reset clears data stored in microcomputer's RAM to ini-
tial conditions.
Procedure:
x
1. Press three buttons of [
], [
ously.
2. "COLD RESET" appears on the fl uorescent indicator tube. Af-
ter that, the fl uorescent indicator tube becomes blank then the
system becomes standby states.
PANEL TEST
Procedure:
?/1
1. Press the [
] button to turn on.
x
2. Press three buttons of [
], [
?/1
and [
] on the set simultaneously.
3. All segments turned on.
x
4. When [
] button on the set is pressed after half segments in
fl uorescent indicator tube light up. If you press [
the set again, another half segments in fl uorescent indicator
x
tube light up. Pressing [
] button on the set again would cause
all segments in fl uorescent indicator tube light up.
.
5. When the [
] button on the remote commander is pressed,
"FY10SCD" and the model name are displayed on the fl uores-
cent indicator tube.
Note: Each time that the [.] button on the remote commander is
pressed, the information displayed on the fl uorescent indicator
tube changes in the order of Destination, MC version, SYS ver-
sion, UI version, DVD version, TA version and DSP version.
However, this cannot be used in service.
N
6. Press [
] button on the set, in the key check mode, the fl uo-
rescent indicator tube displays "K0 J0".
7. Each time an another button is pressed, "KEY" value increas-
es. However, once a button is pressed, it is no longer taken into
account. When all keys are pressed correctly, "K9" and "OK"
are alternately displayed.
.
>
8. When the [
AMS
turned in the direction of right,"J0" is changed to "J1", then ...
.
"J9". When the [
AMS
set is turned in the direction of left, "J0" is changed to "J9",
then ... "J0".
9. To release from this mode, press three buttons in the same
manner as step 2.
10
SECTION 3

TEST MODE

Z
?/1
] and [
] on the set simultane-
.
>
AMS
, PUSH ENTER]
x
] button on
, PUSH ENTER] dial on the set is
>
, PUSH ENTER] dial on the
CDM TEST
Aging test mode of CDM.
Procedure:
X
1. Press three buttons of [
], [
ously.
2. After the "Open" display blinks, "SINGLE LOADING" is dis-
played on the fl uorescent indicator tube.
.
>
3. Press [
AMS
, PUSH ENTER] and then aging starts.
x
4. To stop aging, Press [
] button.
5. To release from this mode, press three buttons of [
?/1
[
] on the set simultaneously.
SERVICE MODE (1)
In this mode, a variety of information is displayed on the fl uo-
rescent indicator tube. Refer to the following table for displayed
various information.
EEPROM CLEAR
Procedure:
x
1. Press two buttons of [
] and [
3 seconds.
2. Various information is displayed on the fl uorescent indicator
tube.
R
3. When [
] button is pressed of the remote commander. Reboot-
ing emergence factor appears of toggle article number on the
fl uorescent indicator tube.
t
4. When [
] button is pressed of the remote commander. MTK
communication error factor appears of toggle article number
on the fl uorescent indicator tube.
r
5. When [
] button is pressed of the remote commander. Power
ON/OFF error factor appears of toggle article number on the
fl uorescent indicator tube.
6. Press the button in order of the [4]
[CLEAR] on the remote commander of attachment.
7. The message "Complete" is displayed on the fl uorescent indi-
cator tube, and EEPROM is cleared.
?/1
Note: Don't press the [
] button when to release from this mode. Nec-
essarily disconnect the power cord. The set doesn't operate when
?/1
turning off power with [
Z
?/1
] and [
] on the set simultane-
X
Z
], [
] and
Z
] on the set simultaneously for
t
[TIME/TEXT]
] button of the set.
t