• Use UP/DOWN arrows to adjust.
• Touch
to return to main display.
EXIT
6.3. TEMPERATURE CALIBRATION
• From the main menu touch
• SCROLL to CAL TEMP.
• Touch
. CAL TEMP will be visible and
YES
adjustment value will be flashing.
• Use UP/DOWN arrows to adjust offset value.
• Touch
to return to the main screen.
EXIT
6.4. ENERGY USAGE MONITOR
A timer in the unit records your system's ON time
for each mode of the current day, previous day,
and cumulative total to let you see the effects of
your temperature settings and weather conditions.
• Select HEAT to monitor heating energy usage or
COOL to monitor cooling usage.
To view ENERGY/USAGE
• From the main menu touch
• SCROLL to ENERGY USAGE.
• Touch
. The current day's ENERGY USAGE
YES
will be displayed.
• Touch
to view yesterday's energy use.
NEXT
• Touch
to advance to total ENERGY usage
NEXT
since the Monitor was last set to zero.
• Touch
to display "000". Touching
NEXT
will toggle between the counter value and "000".
• Touch
to accept the current display value
YES
as the counter value. Use "000" to effect a reset.
• Touch
to return to the main screen.
EXIT
6.5. PROGRAM LOCK
The Program Lock allows the owners/operators to
prevent unauthorized changes to the thermostat's
settings. When the thermostat is locked, a three
digit code is set (000 to 999). That code must be
re-entered before locked settings can be changed
without performing a hardware reset of the unit.
The status of the lock is indicated by an open or
closed padlock icon.
6.5.1. TO SET CODE
• From the main menu touch
• SCROLL to SET KEYBOARD LOCK.
• Touch
. ENTER OLD CODE and both open
YES
and closed padlock icons will be displayed. The
default code is "000".
• Hold UP/DOWN arrows to count to code
number.
• Touch
. ENTER NEW CODE will appear.
YES
• Hold UP/DOWN arrows to count to code
number (Record Code Number).
• Touch
CODE will be visible.
• Touch
6.5.2. TO LOCK SETTINGS
.
MENU
• Touch
KEY? will appear.
• Touch
CLOSED PADLOCK.
6.5.3. TO UNLOCK SETTINGS
• Touch the
displayed.
• Touch
displayed.
• Hold UP/DOWN arrows to count to code
number.
• Touch
symbol will now be displayed in the display.
If you forget your code and the touch screen is
.
MENU
locked, perform a Hardware Reset to unlock it.
With the touch screen unlocked, you may perform
a Software Reset to reset the code to "000". See
"Hardware Reset" and "Software Reset".
7. SETUP OPTIONS
There are Installation Option switches located
inside the thermostat on the rear of its circuit
NEXT
board. They control the following:
7.1. TIME DISPLAY FORMAT 12/24 SWITCH #1
The position of this switch controls whether the
time is displayed in 12 hour or 24 hour Military
Time format.
7.2. SMART RECOVERY SWITCH #2
Smart Recovery allows your HVAC system to
attempt to recover from a setback period and
reach your desired comfort temperature set point
by the beginning of your programmed comfort
period. This option allows you to choose whether
to use Smart Recovery.
When enabled, Smart Recovery will initiate if:
• Recovery is from an evening setback to
morning comfort or day setback to evening
.
MENU
comfort period.
• In Heat mode the temperature set point of the
comfort period must be higher than the setback
period.
• In Cool mode the temperature set point of the
comfort period must be lower than the setback
period.
• The estimated Smart Recovery time must be
longer than 15 minutes for a Smart recovery to be
initiated.
7
to accept new code; ENTER OLD
YES
to return to main display.
EXIT
on display LOCK
OPEN LOCK SYMBOL
. The display will now show a
YES
. UNLOCK KEY? is
CLOSED PADLOCK
. ENTER LOCK CODE will be
YES
to enter code. The OPEN LOCK
YES
Need help?
Do you have a question about the TX9000TS and is the answer not in the manual?
Questions and answers
How to change batteries
To change the batteries in the Lux Products TX9000TS thermostat:
1. Remove the Unit from the Wall: Press up on the thumb latch at the bottom of the thermostat and swing the body up and away to detach it from the wall.
2. Take Out Used Batteries: Remove the old batteries from the compartment.
3. Insert New Batteries: Install two new Energizer® or DURACELL® “AA” size alkaline batteries. Follow the polarity markings shown in the battery compartment.
4. Reattach the Unit: Hang the top of the unit by the tabs at the top corners of the base. Snap the bottom of the unit back into place gently—do not use unnecessary force.
Replace the batteries when the "REPLACE" indicator appears on the display or at least once a year.