Ed bomar
February 16, 2025
How do you know if your controll panel is going bad on a ussc model 5500 pelet stove
1 comments:
Mr. Anderson
February 16, 2025
The control panel on a United States Stove Company model 5500 pellet stove may be failing if it does not respond to button inputs, displays incorrect or no indicators, or fails to reset to factory defaults when the AUX UP and AUX DOWN buttons are held together for three seconds. Additionally, if the heat range setting indicator or AUX indicator does not flash as expected during normal operation or ignition, the control panel may have an issue.
This answer is automatically generated
Related Manuals for United States Stove Company 5500
Summary of Contents for United States Stove Company 5500
Page 1
Certified to comply with 2015 particulate emissions standards. TESTED & PORTLAND, LISTED BY OREGON, USA Report #: 215-S-05b-2 UNITED STATES STOVE COMPANY • 227 INDUSTRIAL PARK ROAD • SOUTH PITTSBURG, TENNESSEE 37380 • WWW.USSTOVE.COM FOR TECHNICAL ASSISTANCE: PHONE: (800) 750-2723 FAX: (423) 837-2109 851641L-1904E...
Safety Precautions This manual describes the installation and operation of the King/Ashley, 5500, 5500XL, 5500M wood heater. This heater meets the 2015 U.S. Environmental Protection Agency's crib wood emission limits for wood heaters sold after May 15, 2015. Under specifi c test conditions this heater has been shown to deliver heat at rates ranging from 9,126 to 27,677 Btu/hr.”...
Page 3
WARRANTY INFORMATION CARD Name__________________________________________ Telephone #: (_____)_____________ City____________________________________________ State_______ Zip_________________ Email Address __________________________________________________________________ Model # of Unit________________________________ Serial #___________________________ Fuel Type: Wood Coal Pellet Gas Other _________________________ Place of Purchase (Retailer)______________________________________________________ City____________________________________________ State_______ Zip_________________ If internet purchase, please list website address___________________________________ Date of Purchase _______________________________________________________________ Alternative Heat Main Heat Source...
Page 4
Fold Here Fold Here Fold Here PLACE STAMP HERE United States Stove Company P.O. Box 151 South Pittsburg, TN 37380...
Hopper Capacity 5500/5500M - 120lbs. (55kg) 5500XL - 320lbs.(146kg) * Pellet size may effect the actual rate of fuel feed and burn times. Fuel feed rates may vary by as much as 20%. Use PFI listed fuel for best results.
Installation This heater is designed to burn only PFI Premium grade pellets. This appliance can also burn pellets rated as standard after May 16, 2015 DO NOT BURN: 1. Garbage; 8. Railroad ties or pressure-treated wood; 2. Lawn clippings or yard waste; 9.
Installation FLOOR PROTECTION This unit must be installed on a non-combustible fl oor surface. If a fl oor pad is used, it should be UL listed or equal. The fl oor pad or non-combustible surface should be large enough to extend a minimum of 6 in. (152.4mm) in front, 6 in. (152.4mm) on each side, and 1 in.
Page 8
D - Adjacent wall to unit 8.00 / 203mm ALCOVE E - Alcove depth 36.00 - 914mm F - Alcove height 60.00 - 1520mm (5500(M) only) TABLE 1 CLEARANCES ALCOVE INSTALLATION THIS INSTALLATION IS NOT APPLICABLE FOR MODEL 5500XL. FIGURE 5...
Page 9
Installation VENTING REQUIREMENTS Install vent at clearances specifi ed by the vent manufacturer. Do not connect the pellet vent to a vent serving any other appliance or stove. Do not install a fl ue damper in the exhaust venting system of this unit. ...
Installation PELLET VENT TERMINATION Do not terminate the vent in an enclosed or semi-enclosed area, such as; carport, garage, attic, crawl space, under a sundeck or porch, narrow walkway, or any other location that can build up a concentration of fumes. The termination must exhaust above the outside air inlet elevation.
Installation THROUGH THE WALL INSTALLATION (RECOMMENDED INSTALLATION) Canadian installations must conform to CAN/CSA-B365. To vent the unit through the wall, connect the pipe adapter to the exhaust motor adapter. If the exhaust adapter is at least 18 in.(457mm) above ground level, a straight section of pellet vent pipe can be used through the wall.
Installation OUTSIDE AIR SUPPLY (optional, unless installing in a mobile home) Depending on your location and home construction, outside air may be necessary for optimal performance. Metal pipe (solid or fl exible) must be used for the outside air installation. PVC pipe is NOT approved and should NEVER be used.
Understanding your stove HOW YOUR STOVE WORKS Your pellet stove utilizes an inclined auger fuel feed system that is operated by a microprocessor controlled digital circuit board. The digital circuit board allows the inclined auger fuel feed system to run in a timer-based, non-continuous cycle; this cycling allows the auger to run for a predetermined period of seconds.
Control Panel Overview Turning the heater ON/OFF, as well as adjustments for the fuel feed rate and room fan speed are performed by pressing the appropriate button(s) on the control panel which is located on the lower left-hand side of your heater. This unit can be changed between an automatic operation or a manual operation.
Operation UNIT PREPARATION After carefully unpacking and reading the instructions for installing your stove, you will need to perform the following steps: • Attach the included spring handle to the door handle by screwing it on in a respective location. •...
Operation START-UP PROCEDURE DO NOT USE CHEMICALS OR FLUIDS TO START THE FIRE - Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fl uid, or similar liquids to start or “freshen up” a fi re in this stove. Keep all such liquids well away from the stove while it is in use.
Operation DAILY OPERATION The hopper and stove top will be hot during operation; therefore, you should always use some type of hand protection when refueling your stove. Never place your hand near the auger while the stove is in operation. This unit should be fi...
Maintenance Failure to clean and maintain this unit as indicated can result in poor performance and safety hazards. Unplug your stove’s electrical cord prior to removing the back panel or opening the exhaust system for any inspection, cleaning, or maintenance work. Never perform any inspections, cleaning, or maintenance on a hot stove.
Maintenance BLOWER MOTORS Clean the air holes on the motors of both the exhaust and distribution blowers annually. Remove the exhaust blower from the exhaust duct and clean out the internal fan blades as part of your fall start-up. PAINTED SURFACES Painted surfaces may be wiped down with a damp cloth.
Trouble Shooting Disconnect the power cord before performing any maintenance! NOTE: Turning the ON/OFF Switch to ”OFF” does not disconnect all power to the electrical components of the stove. Never try to repair or replace any part of the stove unless instructions for doing so are given in this manual. All other work should be done by a trained technician.
Error Codes and Display Indicators Error Error Possible Code Descrption Causes Err1 The high limit temperature sensor • Inadequate ventilation. has tripped. • Room fan failure. • Exhaust Blockage. • Electrical Open in wiring. Err2 Stove ran out of fuel during normal •...
Page 22
Parts Diagram/List models 5500, 5500M & 5500XL Model 5500 PARTS LIST Item Part No. Title Qty. Item Part No. Title Qty. 25490 Door Weldment 88087 Glass Gasket 3.75 ft 891166 Ceramic Glass 83297 8-32 Hex Nut 891188 Glass Retainer, Top...
Page 23
Parts Diagram model 5500, 5500M and 5500XL Note: All repair parts (other than Cabinet Sides, Hopper Assy., and Door Assy.) are same for models 5500, 5500M and 5500XL.
Page 24
891195 Bracket, Drive Motor 80461 Power Supply Cord 25498 Weldment, Top Lid 83516 #4-40 Machine Screw 25511 Weld, Left Side Cabinet (5500) 83542 #4-40 Nylon Lock Nut 25515 Weld, Left Side Cabinet (5500XL) 89390A Rubber Grommet 80558 Circuit Board Assembly...
ALWAYS GIVE THE FOLLOWING INFORMATION AS SHOWN IN THIS LIST: 1. THE PART NUMBER 2. THE PART DESCRIPTION 3. THE MODEL NUMBER:____________________ 4. THE SERIAL NUMBER:____________________ United States Stove Company 227 Industrial Park Road P.O. Box 151 South Pittsburg, TN 37380 (800) 750-2723 WWW.USSTOVE.COM...
Need help?
Do you have a question about the 5500 and is the answer not in the manual?
Questions and answers
How do you know if your controll panel is going bad on a ussc model 5500 pelet stove
The control panel on a United States Stove Company model 5500 pellet stove may be failing if it does not respond to button inputs, displays incorrect or no indicators, or fails to reset to factory defaults when the AUX UP and AUX DOWN buttons are held together for three seconds. Additionally, if the heat range setting indicator or AUX indicator does not flash as expected during normal operation or ignition, the control panel may have an issue.
This answer is automatically generated