3. RECEIVING
(BASE STATION)
Test
(1)
(2)
(3)
(4)
(5)
(6)
(7)
Equipment
FM SSG (50 ohm, OPEN type)
AF VTVM
Distortion
meter
Dummy Load (600 ohm)
AC Adaptor (DC 9.OV --- center minus)
Loop Simulator
Power Supply (DC 48V)
I
(!
I
1-
1. RXIF
(1) Connect
a FM SSG (1 kHz mod.,
1.5 kHz dev.,
39.800 MHz,, 46dBp) to the CN101.
(2) Connect an AF-VTVM
and distortion
meter in parallel
and terminate
a 600
ohm
dummy
load across
the
TEL line.
(3) Adjust T301 so that the reading
of the AF volhmeter
is maximum
level and minimum
distortion
at distor-
tion rmeter.
Unit Condition
(1)
(2)
(3)
Set a S403 "RINGER"
to LO / HI position.
Set a S404 "ANS.ONLY"
to ANS. ONLY position.
Setting band :6 channel (39.800 MHz)
Select
channel
6 by
"FFWD"
button
pushed
six
times at speedy. Confirm at Frequency
Counter only
when changed
a S403 "PULSE I TONE"
to PULSE
position
.
Push "PLAY"
button.
2. RX RF
(1) Connect a FM SSG (46dB,~ 4 10clB~) to the
CN101.
(2)
Adjust
T101 so that the reacting of the distortion
me-
ter is minimum
distortion
(less than 100/~).
3. RX AF LEVEL
(1) Connect a
FM
SSG
(l OCIBP -+
46dB~) to the
CNIO1.
(2)
Adjust
VR301
so that the reading
of the AC volt-
meter is -10 dBm t 1 dB at TEL line.
STEP
CONDITION
ADJUST
ADJUST
VALUE
SPECIFICATION
1.
RXIF
FM SSG : 46dBP
T301
Maximum
Level at
-.--.-
Minimum
Distortion
2.
RX RF
FM SSG :
10dBJ,
T101
Minimum
Distortion
less than
107.
3.
RX AF LEVEL
FM SSG : 46dB/
VR301
-10 dBm
-10 dBm f 1
dB (1
kHz)
-7.5 dBm f3
dB (300 Hz)
-19 dBm ~3 dB (3
kHz)
CN101
Unit
L1OI(H)
FM SSG
(DPX
side)
TEL LINE
LOOP
AF
SIMULATOR
~
GND(E)
VTVM
TEST
Dummy
Mod. :1 kHz
GND
600 ohm
D12v.
:1.5
kHz
POWER
SUPPLY
Distortion
Meter
Op
DC 48V
(OPTIONAL)
–24–