Register Contents - Panasonic AN30182A-EVB User Manual

Table of Contents

Advertisement

Regulations
1824S02E
No.
4.3

Register Contents

This section describes register contents on operating window of serial controller software.
For further details, please refer to the register map in section 4.4.
Figure 10. Register Contents on Operating Window of Serial Controller Software
1) every LDO and DCDC ON/OFF select register
2) Register for output voltage setup of DCDC1
3) Register for output voltage setup of DCDC2
4)Register for output voltage setup of LDO1
5)Register for output voltage setup of LDO2
6)Register for output voltage setup of LDO3
7)Register for output voltage setup of LDO4
8)Register for output voltage setup of LDO5
9)Register for output voltage setup of LDO6
10) every LDO Power save mode select register
11) LDO1EN Enable
e.g. LDO1=3.3V:ON (Power save mode)
・1) Write 000H(Address), 04H(Data) : LDO1:ON
・4) Write 002H(Address), 0FH(Data) : LDO1=3.3V
・10) Write 005H(Address), 01H(Data) : Power save mode
Note: The parameters above is subject to change for improvement without notice.