Regulations
1824S02E
No.
4.2
Operating Instructions
Operating Instructions on Operating window of Serial Controller software.
Figure 9. Operating Instructions on Operating Window of Serial Controller Software
1)Slave Address
Set Slave Address of I2C communication. Choose [ L=1110010x ]. Choose the same one as the SW_ASEL setting on
AN30182A Evaluation Board.
2)Set Write Data
Click the bit data you want to change, the data will be changed 0⇒1 or 1⇒0.
3)Indicate Read Data
8bit binary data read from AN30182A IC is indicated.
4)Write Data (1 Address)
Send the write data set at 2)
5)Read Data (1 Address)
Read 8bit binary data from AN30182A IC and indicate at 3).
6) Write Data (All Address)
Send all write data set in the operating window.
7)Read Data (All Address)
Read all data from AN30182A IC and indicate to the operating window.
8)Write Data (All Address) Repeatedly
Repeat 6) infinitely.
9)Read Data (All Address) Repeatedly
Repeat 7) infinitely.
10)Stop
Stop 8) and 9).
Note: The parameters above is subject to change for improvement without notice.