AUTOMATIC TECHNOLOGY AUSTRALIA PTY LTD GDO-6 V1 Slim-Drive EasyRoller ® ROLL UP GARAGE DOOR OPENER Warning: It is vital for the safety of persons to OWNERS COPY follow all instructions. Failure to comply with the installation instructions and the safety warnings...
TABLE OF CONTENTS Safety Warnings............Product Features............Operating Controls............Package Contents............Side Room Requirements..........Fixing Weight Bars........... Fitting Locking Bar Covers .......... Easy Access Transmitter..........Mounting The Opener..........Fixing Curtain To Drum........... Setting Limits Via Control Panel........ Setting Limits Via Transmitter........Setting Obstruction Force Margin (ISS).....
Automatic Technology Australia Pty Ltd to the extent that such may be lawfully excluded hereby expressly disclaims all conditions or warranties, statutory or otherwise which may be implied by laws as conditions or warranties of purchase of an Automatic Technology Australia Pty Ltd Roll Up Garage Door Opener.
FEATURES Thank you for purchasing the ATA ISS (INTELLIGENT SAFETY VACATION MODE EasyRoller Automatic Garage Door OBSTRUCTION SYSTEM) A hand held transmitter can be Opener. This opener is designed to suit While the door is performing a close programmed to lock and unlock all vertical operating continuous curtain cycle, should it hit an obstacle or be other transmitters that have being...
OPERATING CONTROLS 24V OUTPUT supplies 24V DC CLOSE drive button (red) is used O/S/C button (Yellow) is used at 30mA to power an external during installation to help set the during installation to test the open, receiver, or electronic device, etc. close limit position.
Page 7
OPERATING CONTROLS P.E. SHUNT, OSC INPUT, LIGHT INPUT ENGAGE/DISENGAGEMENT HANDLE 24V DC OUTPUT INC. EASY ACCESS TRANSMITTER LIGHT CODE BUTTON (WHITE) SET BUTTON (YELLOW) CODING LED (RED) O/S/C BUTTON (YELLOW) DOOR CODE BUTTON (BLUE) BATTERY CHARGER INPUT DOOR STATUS LED (YELLOW) OPEN DRIVE BUTTON (GREEN) CLOSE DRIVE BUTTON (RED) OPEN LIMIT LED(GREEN)
PACKAGE CONTENTS ITEM QUANTITY GDO-6 SLIM-DRIVE EASYROLLER DRIVE UNIT ® EASY ACCESS TRANSMITTER EAT-1 (NOT INCLUDED IN SOME MODELS) KEY RING TRANSMITTER PTX-4 PTX-4 WALL MOUNT BRACKET ALKALINE BATTERY A23 12V WEIGHT BAR (NOT INCLUDED IN SOME MODELS) PAN HEAD SCREW M4x50mm (NOT INCLUDED IN SOME MODELS) NILOCK HEX NUT M4 (NOT INCLUDED IN SOME MODELS) FLAT WASHER I.D 3/16 x 1/2 (NOT INCLUDED IN SOME MODELS) SCREW #6x1”...
BEFORE INSTALLATION IMPORTANT SAFETY INSTRUCTIONS FOR FIG. 1 INSTALLATION Warning: Incorrect installation can lead to severe injury. Follow ALL installation instructions. SIDE ROOM REQUIREMENTS Fig. 1 shows the minimum and recommended side room that is required to mount the opener. The distance between the edge of the door curtain and the inside of the bracket must be at least 40mm.
EASY ACCESS TRANSMITTER 4. EASY ACCESS TRANSMITTER FIG. 4 The Easy Access Transmitter is prepared ready for use with the battery pre-installed. Before the transmitter can be operational, the Transmitter Code has to be stored into the openers memory. To store the code please follow the instructions in Step 10.1 on page 15.
MOUNTING THE OPENER 5. FIXING DRIVE UNIT TO THE DOOR FIG. 8 The EasyRoller Drive Assembly can be fixed to the roll up garage door in a variety of ways. Described below is one method of fixing. Make sure there is enough side room to slide the drive assembly onto shaft.
SETTING LIMITS 6. FIXING OF DOOR CURTAIN TO DRUM FIG. 11 WHEEL The door curtain has to be secured to the drum wheel with suitable fasteners. 1. With the door in the fully closed position, mark the curtain (Fig. 11) on both ends of the door. 2.
SETTING LIMITS 8. SETTING DOOR TRAVEL LIMIT FIG. 14 POSITIONS – METHOD TWO - VIA THE REMOTE CONTROL IMPORTANT NOTE: The O/S/C button will not function until the open and close limits position are set. NOTE: The opener is factory preset for installation on the RIGH HAND SIDE.
SETTING SAFETY OBSTRUCTION FORCE 9. SAFETY OBSTRUCTION TEST FIG. 16 Please take care when testing the Safety Obstruction Force. Due to Excessive forces failure to follow this warning may cause SERIOUS PERSONAL INJURY and/or property damage. The test below should be repeated at regular intervals (approximately every two months).
CODING TRANSMITTERS 10. SETTING TRANSMITTERS CODES FIG. 18 Make sure to insert the battery into the transmitters. The memory in the openers receiver can store up to 23 remote control transmitters. 10.1 STORING THE TRANSMITTERS CODE 1. Press and hold the Door Code button (Fig. 18). 2.
CODING TRANSMITTERS 11. STORING TRANSMITTER(S) FROM A FIG. 20 REMOTE LOCATION Using this method you don’t need to have access to the control panel on the Door Opener. However, you do need a transmitter that is pre coded to the controller’s receiver. IMPORTANT NOTE: The Door or Courtesy Light must be activated when the step below is performed.
PE BEAM AND AUTO CLOSE 13. FITTING THE SAFETY PHOTO FIG. 22 ELECTRIC BEAM SENSOR (OPTIONAL) Locate the Photo Electric Beam (P.E.) normally closed contact REMOVE type in a strategic location within doorway. We recommend PE SHUNT 150mm above the floor level and as close as possible to the door opening, inside the garage.
FINAL SET UP 16. SETTING OF COURTESY LIGHT TIME FIG. 25 The preset courtesy light time on the door opener is 3 minutes. This time can be changed by the following: 1. Press in and hold both the Auto Close Time button and Force Margin Set buttons (Fig.
PARAMETERS DOOR STATUS INDICATORS DOOR OPENER STATE OPEN LED CLOSE LED DOOR STATUS BEEPER GREEN LED YELLOW OPEN CLOSE OPENING FLASHING FLASHING CLOSING DOOR TRAVEL STOPPED FLASHING FLASHING DOOR OBSTRUCTED WHEN OPENING FLASHING BEEPS WHILE DOOR OBSTRUCTED WHEN CLOSING FLASHING DOOR IS MOVING ALTERNATING ALTERNATING...
SPECIFICATIONS AND DEFAULT SETTINGS FACTORY DEFAULT SETTINGS DEFAULT STEP MAXIMUM MAXIMUM MOTOR RUN TIME 25 Secs. — — COURTESY LIGHT TIME 3 Mins. 10 Secs. 4 Mins. OBSTRUCTION FORCE MARGIN AUTO CLOSE TIME 0 Secs. 1 Sec. 4 Mins. TECHNICAL SPECIFICATIONS INPUT VOLTAGE: 230V- 240V AC 50Hz (Other voltages available upon request...
TROUBLE SHOOTING SYMPTOM POSSIBLE CAUSE REMEDY Switch on mains power. Door will not operate. Mains power not switched on. Remove obstruction. Door is obstructed. Unlock door or remove jam. Door is locked or motor jammed. Door requires service/repair by qualified Door tracks/hardware damaged.
WARRANTY AND EXCLUSION OF LIABILITY Subject to all of the matter set out below, Automatic Technology Australia Pty Ltd ("ATA") warrants the EasyRoller Roll Up ® Door Opener (“The Product”) for twenty four (24) months, from the date of purchase (specified in the sales docket receipt) that the product is free of any defects in material and workmanship rendering it unmerchantable.
Need help?
Do you have a question about the GDO-6 V1 Slim-Drive EasyRoller and is the answer not in the manual?
Questions and answers