AUTOMATIC TECHNOLOGY AUSTRALIA PTY LTD GDO-4 V4 EasyRoller ® ROLL UP GARAGE DOOR OPENER Warning: It is vital for the safety of persons to OWNERS COPY follow all instructions. Failure to comply with the installation instructions and the safety warnings...
TABLE OF CONTENTS Safety Warnings............Product Features............Operating Controls............Package Contents............Side Room Requirements..........Fixing Weight Bars........... Left/Right Hand Installation......... Easy Access Transmitter..........Mounting The Opener..........Fixing Curtain To Drum........... Setting Limits Via Control Panel........ Setting Limits Via Transmitter........Setting Obstruction Force Margin (ISS)..... Coding Transmitters ...........
Automatic Technology Australia Pty Ltd to the extent that such may be lawfully excluded hereby expressly disclaims all conditions or warranties, statutory or otherwise which may be implied by laws as conditions or warranties of purchase of an Automatic Technology Australia Pty Ltd Roll Up Garage Door Opener.
FEATURES Thank you for purchasing the ATA ISS (INTELLIGENT SAFETY VACATION MODE EasyRoller Automatic Garage Door OBSTRUCTION SYSTEM) A hand held transmitter can be Opener. This opener is designed to suit While the door is performing a close programmed to lock and unlock all vertical operating continuous curtain cycle, should it hit an obstacle or be other transmitters that have being...
OPERATING CONTROLS LIGHT CODE button (white) is CLOSE LIMIT LED (red) the led OPEN LIMIT LED (green) the used for storing or erasing the is very helpful during installation. very helpful during transmitter button (code) you wish It illuminates and flashes when the installation.
Page 7
OPERATING CONTROLS LIGHT CODE BUTTON (WHITE) AUTO CLOSE BUTTON (WHITE) CODING LED (RED) MOTOR CONNECTOR DOOR CODE BUTTON (BLUE) BATTERY CHARGER INPUT P.E. SHUNT FORCE MARGIN SET BUTTON DOOR STATUS LED (YELLOW) OPEN LIMIT LED(GREEN) RX INPUT OPEN DRIVE BUTTON (GREEN) PROG INPUT O/S/C BUTTON (YELLOW) CLOSE DRIVE BUTTON (RED)
PACKAGE CONTENTS ITEM QUANTITY GDO-4 EASYROLLER DRIVE UNIT EASY ACCESS TRANSMITTER EAT-1 (NOT INCLUDED IN SOME MODELS) KEY RING TRANSMITTER PTX-4 PTX-4 WALL MOUNT BRACKET ALKALINE BATTERY A23 12V WEIGHT BAR (NOT INCLUDED IN SOME MODELS) SCREW M5x40mm (NOT INCLUDED IN SOME MODELS) HEX NUT M5 (NOT INCLUDED IN SOME MODELS) SPRING WASHER I.D 5 (NOT INCLUDED IN SOME MODELS) SCREW #6x1”...
BEFORE INSTALLATION IMPORTANT SAFETY INSTRUCTIONS FOR MINIMUM SIDE ROOM FIG. 1 INSTALLATION Warning: Incorrect installation can lead to severe injury. Follow ALL installation instructions. SIDE ROOM REQUIREMENTS Fig. 1 shows the minimum side room that is required. The distance between the edge of the door curtain and the inside of the bracket is 85mm minimum, and the distance between the edge of the door curtain and the outside of the bracket is 135mm minimum.
EASY ACCESS TRANSMITTER THE EASY ACCESS TRANSMITTER FIG. 6 The Easy Access Transmitter is prepared ready for use with the battery pre-installed. Before the transmitter can be operational, the Transmitter Code has to be stored into the openers memory. To store the code please follow the instructions in Step 9.1 on page 15.
MOUNTING THE OPENER 4. FIXING DRIVE UNIT TO THE DOOR FIG. 10 CHECK IF “U” The EasyRoller Drive Assembly can be fixed to the roll up BOLT IS TIGHT garage door in a variety of ways. Below we will describe one method of fixing.
SETTING LIMITS 5. FIXING OF DOOR CURTAIN TO DRUM FIG. 13 WHEEL The door curtain has to be secured to the drum wheel with suitable fasteners. 1. With the door in the fully closed position, mark the curtain (Fig. 13) on both ends of the door. 2.
SETTING LIMITS 7. SETTING DOOR TRAVEL LIMIT FIG. 16 POSITIONS – METHOD TWO - VIA THE REMOTE CONTROL IMPORTANT NOTE: The O/S/C button will not function until the open and close limits position are set. 7.1 SETTING LIMITS 1. With the drive assembly in manual mode (Fig. 14) move the door up by hand to an approximately mid open position.
SETTING SAFETY OBSTRUCTION FORCE 8. SAFETY OBSTRUCTION TEST FIG. 18 Please take care when testing the Safety Obstruction Force. Excessive forces may cause SERIOUS PERSONAL INJURY and/or property damage can result from failure to follow this warning. The test below should be repeated at regular intervals (approximately every two months).
CODING TRANSMITTERS 9. SETTING TRANSMITTERS CODES FIG. 20 Make sure to connect the battery to the transmitters. The memory in the openers receiver can store up to 23 different remote control transmitters. Press and hold Door Code 9.1 STORING THE TRANSMITTERS CODE Button 1.
CODING TRANSMITTERS 10. STORING TRANSMITTER(S) FROM A FIG. 22 REMOTE LOCATION Using this method you don’t need to have access to the control panel on the Door Opener. However, you do need a transmitter that is pre coded to the controller’s receiver. IMPORTANT NOTE: The Door or Courtesy Light must be activated when the step below is performed.
PE BEAM AND AUTO CLOSE 12. FITTING THE SAFETY PHOTO FIG. 25 ELECTRIC BEAM SENSOR (OPTIONAL) Locate the Photo Electric Beam (P.E.) normally closed contact type in a strategic location within doorway. We recommend 150mm above the floor level and as close as possible to the door opening, inside the garage.
FINAL SET UP 15. SETTING OF COURTESY LIGHT TIME FIG. 27 The preset courtesy light time on the door opener is 3 minutes. This time can be changed by the following: 1. Press in and hold both the Auto Close Time button and Force Margin Set button (Fig.
PARAMETERS DOOR STATUS INDICATORS DOOR OPENER STATE OPEN LED CLOSE LED DOOR STATUS BEEPER GREEN LED YELLOW OPEN CLOSE OPENING FLASHING FLASHING CLOSING DOOR TRAVEL STOPPED FLASHING FLASHING DOOR OBSTRUCTED WHEN OPENING FLASHING BEEPS WHILE DOOR OBSTRUCTED WHEN CLOSING FLASHING DOOR IS MOVING ALTERNATING ALTERNATING...
SPECIFICATIONS AND DEFAULT SETTINGS FACTORY DEFAULT SETTINGS DEFAULT STEP MAXIMUM MAXIMUM MOTOR RUN TIME 30 Secs. — — COURTESY LIGHT TIME 3 Mins. 10 Secs. 4 Mins. OBSTRUCTION FORCE MARGIN AUTO CLOSE TIME 0 Secs. 1 Sec. 4 Mins. TECHNICAL SPECIFICATIONS INPUT VOLTAGE: 230V- 240V AC 50Hz (Other voltages available upon request...
TROUBLE SHOOTING SYMPTOM POSSIBLE CAUSE REMEDY Switch on mains power. Door will not operate. Mains power not switched on. Remove obstruction. Door is obstructed. Unlock door or remove jam. Door is locked or motor jammed. Door requires service/repair by qualified Door tracks/hardware damaged.
WARRANTY AND EXCLUSION OF LIABILITY Subject to all of the matter set out below, Automatic Technology Australia Pty Ltd ("ATA") warrants the EasyRoller Roll Up ® Door Opener (“The Product”) for twenty four (24) months, from the date of purchase (specified in the sales docket receipt) that the product is free of any defects in material and workmanship rendering it unmerchantable.