RESETTING THE TOTAL LAMP TIMER

Resetting the counter
» Draw out the lamp to be replaced. Turn on the power and the absence of the lamp is detected. Now reset the total
hour counter.
Resetting procedure
Replacing one lamp
1
Draw out the relevant lamp only.
2
3
The LED indicator at the drawn-out lamp side starts flashing.
4
Press the ENTER key to reset the counter. The LED indicator goes out.
5
Turn off the main power. Fit a new lamp into position.
» With just one of the lamps drawn out, the optical mechanism may get unstable in temperature. To avoid this,
the projector comes in the reset mode.
» For two or more projectors, their counters cannot be reset at once using the remote controller. Press the
ENTER key for resetting.
» In the process mode, the historical information is also reset.
Maintenance Indicator
TEMPERATURE
The internal
WARNING indicator
temperature is
abnormally high.
LAMP REPLACE-
The lamp does
MENT indicator
not light up.
(LAMP1, LAMP2)
POWER indicator
The POWER
indicator flashes
in red when the
projector is on.
Turn on the main power.
Press POWER button to LCD projector on.
End
Condition
Problem
· Blocked air intake.
· Clogged air filter.
· Cooling fan breakdown.
· Internal circuit failure.
· Burnt-out lamp.
· Lamp circuit failure.
· The filter cover is open.
· The lens cover is miss-
ing.
Replacing both lamps
Draw out both the lamps.
· Relocate the projector to an area with
proper ventilation.
· Clean the filter.
· Take the projector to your nearest Au-
thorized Sharp Industrial LCD Products
Dealer or Service Center for repair.
· Carefully replace the lamp.
· Take the projector to your nearest Au-
thorized Sharp Industrial LCD Products
Dealer or Service Center for repair.
· Securely install the filter cover.
· Securely install the lens cover
(CCOVA1785CE01).
19