Alarm Relay Output
The alarm relay output is activated when an alarm condition
exists. The alarm output is only active for the duration of the
alarm.
Alarm relays can be programmed in the menu system to
respond to macros, and video loss. See section 3.11 for
information about configuring the alarms in the menu system.
External Alarm Acknowledge Input
Connect a switch or similar device to ground this pin in order
to acknowledge an alarm condition, and silence associated
buzzers and relays. Connect from pin 23 to either pin 18, 19,
or 20 (ground pins).
NOTE
All specifications subject to change without notice. GE-Interlogix believes all specifications
to be correct at time of printing, but no liability is assumed for omissions or errors.
RS485 Connector
Shields are grounded at one end, preferably at the
e
DVMR
Triplex eZ.
See section 3.15 for information about configuring
the RS485 network address settings in the menu
system.
RJ-45 Pin Configuration For RS485 Port
Pin
Use
1
Ground (Shield)
2
Not Connected
3
Network +VE
4
Not Connected
Ethernet Port
The cable connection configuration depends on your
network configuration:
e
For a DVMR
Triplex eZ that connects directly to
a Hub or Switch, use a straight through
connection.
e
For a DVMR
Triplex eZ that connects directly to
a PC, use a cross over connection.
Consult with your MIS personnel for the specific type
of configuration. See section 3.15 for information
about configuring the ethernet settings in the menu
system.
0150-0198B
Output: Normally Open Zero
potential relay contact.
Voltage: 30V (Max)
Current: 500mA (Max)
External Device: Normally Open
Zero potential relay contact.
Wire Type: #24 AWG, twisted pair with shield
Connector Type: RJ-45
Max. Cable Length: 3200 feet / 1000 meters
Pin
Use
5
Not Connected
6
Network -VE
7
Ground (Shield)
8
Not Connected
Wire Type: Cat 5
Connector Type: RJ-45
Max. Cable Length: 100 meters / 328 ft.
Min. Cable Length: 6 feet / 1.8 meters
Hub Wiring Configuration: Straight Through
PC Wiring Configuration: Cross Over
11
(2-wire)
1
2 3 4 5 6 7
RJ-45 socket on

back panel.

e
Calibur DVMR
8
Triplex eZ