External synchronization switch

The settings of the alarm input/output are configured on the SETUP menu.
Refer to the operating instructions (PDF) for further information.
Important:
• Be sure to turn off the power of each device before connection.
Alarm output
Input specification: Open collector out-
put (max. voltage: 16 V DC)
Off: Internally pulled up
2 V to 4 V DC
On: Output voltage 1 V DC or less (max.
drive current: 100 mA)
Functions: Alarm output
Color/BW switching output
Alarm input
Input specification: No-voltage make
contact input (3 to 5 V DC, internally
pulled up)
Off: Open or 3 to 5 V DC
On: Make contact with GND (required
drive current: 0.2 mA or more)
Functions: Alarm input
* When an external device is connected, exercise care to avoid exceeding the rating.
* Applicable wire: AWG #22 - #28 Single core, twisted
Before connection, remove 9 mm to 10 mm of the wire sheath and
twist the wire enough to prevent the short circuit.
* Check whether the stripped part of the wire is not exposed from
the external terminal and is securely connected.
18
VMD enabling input
Color/BW switching input
Scene file switching input
ALARM OUT
POWER
GND
ALARM IN
220 - 240V ~ 50Hz
ALARM OUT (Alarm output)
GND
ALARM IN (Alarm input)
The external terminal is the same between
WV-CP500 and WV-CP504.
The external terminal is the same between
WV-CP500 and WV-CP504.
WV-CP500
VIDEO OUT
WV-CP500
ALARM OUT
POWER
GND
ALARM IN
VIDEO OUT
220 - 240V ~ 50Hz
ALARM OUT (Alarm output)
GND
ALARM IN (Alarm input)
Stripped
9 mm - 10 mm

Hide quick links:

Advertisement