Samsung NH080PHXEA User Manual
Hide thumbs Also See for NH080PHXEA:

Advertisement

E
S
F
I
P D D

Air Conditioner

user manual

imagine
Thank you for purchasing this Samsung product.
To receive more complete service, please
register your product at
www.samsung.com/register
DB98-00000A(1)
the possibilities
Air to Water Heat Pump
NH080PHXEA
NH160PHXEA

Advertisement

Table of Contents
loading

Summary of Contents for Samsung NH080PHXEA

  • Page 1: Air Conditioner

    Air to Water Heat Pump NH080PHXEA NH160PHXEA Air Conditioner user manual imagine the possibilities Thank you for purchasing this Samsung product. To receive more complete service, please register your product at www.samsung.com/register P D D DB98-00000A(1)
  • Page 2 Floor heating is well known as the optimal heating option for indoor thermal comfort. However, it takes 4~8 hours to heat up the room after it is turned on. Samsung EHS TDM technology quickens that process by blowing hot air along with floor heating to warm up the room.
  • Page 3: Table Of Contents

    Contents Contents SAFETY INFORMATION Safety information VIEWING THE UNIT Control panel CHECKING THE FUNCTION OF Space operation mode DHW operation mode BUTTONS AND ICONS Temperature adjustment Hot key Schedule Status indicator Optional function indicator OPERATING BASIC FUNCTION Available operation mode Space heating operation Space cooling operation Water law operation...
  • Page 4: Safety Information

    Because the following operating instructions cover various models, the characteristics of your air conditioner may differ slightly from those described in this manual. If you have any questions, call your nearest contact center or find help and information online at www.samsung.com. Important safety symbols and precautions: Hazards or unsafe practices that may result in severe personal injury or death.
  • Page 5 Do not install this appliance near a heater, inflammable material. Do not install this appliance in a humid, oily or dusty location, in a location exposed to direct sunlight and water (rain drops). Do not install this appliance in a location where gas may leak. •...
  • Page 6 Safety information Safety information CAUTION SIGNS FOR POWER SUPPLY CAUTION When not using the air conditioner for a long period of time or during a thunder/lightning storm, cut the power at the circuit breaker. • Failing to do so may result in electric shock or fire. WARNING SIGNS FOR USING WARNING If the appliance is flooded, please contact your nearest service centre.
  • Page 7 Do not attempt to repair, disassemble, or modify the appliance yourself. • Do not use any fuse (such as cooper, steel wire, etc.)other than the standard fuse. • Failing to do so may result in electric shock, fire, problems with the product, or injury. If any foreign substance such as water has entered the appliance, cut the power by unplugging the power plug and turning the circuit breaker off and then contact your nearest service centre.
  • Page 8 Safety information Safety information WARNING SIGNS FOR CLEANING WARNING Do not clean the appliance by spraying water directly onto it. Do not use benzene, thinner or alcohol to clean the appliance. • This may result in discoloration, deformation, damage, electric shock or fire. Before cleaning or performing maintenance, unplug the air conditioner from the wall socket and wait until the fan stops.
  • Page 9: Viewing The Unit

    Viewing the unit Viewing the unit CONTROL PANEL Power(Space mode) Power(DHW mode) Display panel Mode button (Space mode) Mode button (DHW mode) Up/Down button Set button View button Daily schedule setting button DHW hot key Weekly schedule setting button Cancel/Delete button Outing hot key Silent button Schedule Set button...
  • Page 10: Checking The Function Of

    Checking the function of buttons and indicators Checking the function of buttons and indicators SPACE OPERATION MODE Mode Button Display Function Operation Space heating & cooling It can supply heating and cooling to the space when Operation the Power(Space mode) button is on. mode Results: The heat pump will run in heating or cooling mode.
  • Page 11: Dhw Operation Mode

    DHW OPERATION MODE Mode Button Display Function Operation Water heating Operation It can supply warm water to the DHW tank when the Power(DHW mode) button is pressed. mode Results: Heat pump will be turned on with the domestic water heating mode. Economic Economic DHW mode, which is operated by heat mode...
  • Page 12: Temperature Adjustment

    Checking the function of buttons and indicators Checking the function of buttons and indicators TEMPERATURE ADJUSTMENT Mode Button Display Function Operation Temperature Adjust To push up and down, modulate the water (Air) temperature. mode Supply water temperature to the load Domestic water temperature Room temperature Outdoor temperature...
  • Page 13: Hot Key

    HOT KEY Mode Button Display Function Hot key To adjust the current setting temperature, press these buttons to set the desired temperature. Results: The temperature can be set between 5°C to 55°C and be adjusted by 0.5°C. Down When DHW mode is enabled, it is assured that the full capacity of the heat pump is used for domestic water heating only.
  • Page 14: Schedule

    Checking the function of buttons and indicators Checking the function of buttons and indicators SCHEDULE Mode Button Display Function Schedule The system is operating according to a certain schedule which is pre-defined by users or installers. 14_ Checking the function...
  • Page 15: Status Indicator

    STATUS INDICATOR Mode Status Display Function Status Compressor On This icon indicates that the compressor in the outdoor unit is active. Back-up heater These icons indicate that the back-up heater in the hydro unit is operating on 1 step(2kW) 2 step(6kW) Booster heater On This icon indicates that the booster heater in the DHW tank is active(3kW).
  • Page 16: Optional Function Indicator

    Checking the function of buttons and indicators Checking the function of buttons and indicators OPTIONAL FUNCTION INDICATOR Mode Button Display Function Optional The priority of operating heat pump is allowed to A2A function Operating while it demands both A2A and A2W. When this A2A operating sign is on, it is assured that the heat pump is used for A2A only.
  • Page 17: Operating Basic Function

    Operating basic function Operating basic function AVAILABLE OPERATION MODE Heating mode and cooling mode can not operate at the same time. Heating Cooling Water law Heating + DHW Cooling + DHW Water law + DHW Urgent DHW Outing (heating) Outing (heating + DHW) Operating basic function _17...
  • Page 18: Space Heating Operation

    Operating basic function Operating basic function SPACE HEATING OPERATION In this mode, heating will be activated as required by the water temperature set point. • The set point can be set manually • or set weather dependant 1. Press Power(Space mode) button to turn on the heat pump unit.
  • Page 19: Space Cooling Operation

    SPACE COOLING OPERATION In this mode, cooling will be activated as required by the water temperature set point. • The set point can be set manually • or set weather dependant 1. Press Power(Space mode) button to turn on the heat pump unit.
  • Page 20: Water Law Operation

    Operating basic function Operating basic function WATER LAW OPERATION In this mode, the heat pump operates according to the parameters for the weather dependent. • The set point can be set manually • or set weather dependant 1. Press Power(Space mode) button to turn on the heat pump unit.
  • Page 21: Domestic Water Heating Operation

    DOMESTIC WATER HEATING OPERATION In this mode, domestic water heating will be activated as required by the water temperature set point. • The set point can be set manually 1. Press Power(DHW mode) button to turn on DHW tank. The priority between heating/cooling/water-law and DHW modes are depending upon the user’s input of Field Setting Value of Wired Remote Controller.
  • Page 22: Operating Hot Key Function

    Operating hot key function Operating hot key function URGENT DHW MODE If you want to enjoy a leisurely bath or need a lot of warm water urgently, select the DHW hot key. When this mode is enabled, it is assured that the full capacity of the heat pump is only delivered for domestic water heating.
  • Page 23: Outing Mode

    OUTING MODE If you want to take a vacation, you can use the Outing hot key. When this mode is enabled, it is assured that the heat pump maintains your house at a lower temperature to save energy cost. 1. Press Outing Hot key. The heat pump delivers heat at a low temperature.
  • Page 24: Operating Advanced Function

    Operating advanced function Operating advanced function SETTING THE TIME Your hydro unit contains a clock used to start and stop the unit automatically at a given time. You must set the time when you purchase the hydro unit or reset the main power. 1.
  • Page 25: Setting The 7-Day(Weekly) Schedule

    SETTING THE 7-DAY(WEEKLY) SCHEDULE Set the 7 schedule to reserve the On/Off timer to be repeated every week. At most 7 schedules may be set for each day. • When using room thermostat, it is impossible to reserve • If weekly schedule reserved 7 items is on same day, it is impossible to reserve. In that case, When press the Weekly button, change the View mode of reservation.
  • Page 26 Operating advanced function Operating advanced function SETTING THE 7-DAY(WEEKLY) SCHEDULE 6. Set the hour by pressing the Up or Down button. The ‘hour’ indicator will blink. Set the hour and press Set button to save the setting. 7. Set the minute by pressing the Up or Down button. The ‘minute’...
  • Page 27 Deleting the 7-day(Weekly) schedule 1. Select the schedule from Reservation View Mode. 2. Push the Cancel/Delete button for 3 seconds. 3. The LCD pictures changes to the reservation mode after delete the schedule. Operating the 7-day(Weekly) schedule 1. Operate automatically according to schedule. 2.
  • Page 28: Setting The Daily Schedule

    Operating advanced function Operating advanced function SETTING THE DAILY SCHEDULE Set the daily schedule to reserve On / Off timer of DHW(Eco/Std/Power) and Silent mode. At most 15 schedules may be set for day. • If the field setting is for no use DHW and use other manufacturer tank, it is impossible to reserve “DHW”...
  • Page 29 4. Set the hour by pressing the Up or Down button. The ‘hour’ indicator will blink. Set the hour and press Set button to save the setting. 5. Set the minute by pressing the Up or Down button. The ‘minute’ indicator will blink. Set the minute and press Set button to save the setting.
  • Page 30 Operating advanced function Operating advanced function SETTING THE DAILY SCHEDULE Deleting the daily schedule 1. Select the schedule from Reservation View Mode. 2. Push the Cancel/Delete button for 3 seconds. 3. The LCD pictures changes to the reservation mode after deleting the schedule. Operating the daily schedule 1.
  • Page 31: Field Setting Mode

    FIELD SETTING MODE Setting the Field Setting Value of wired remote controller Field setting is for changing the operation schemes of system according with customer’s demands. Field setting is accessible and programmable by wired remote controller of hydro unit. Default field setting value and range is on 33~35 pages. 1.
  • Page 32 Operating advanced function Operating advanced function FIELD SETTING MODE Field Setting Value(FSV) Table Field setting values consist of 4 digits. (First 2 digits for main menu, last 2 digits for sub menu) Field setting values can be changed even during the normal operation of system. •...
  • Page 33 • Code 30✴✴ : User’s options for domestic hot water(DHW) tank heating 3011 : Application of DHW tank in user’s system 302✴ : Heat pump variables for tank temp. control and combination with booster heater 303✴ : Booster heater variables for combination with heat pump 304✴...
  • Page 34 Operating advanced function Operating advanced function FIELD SETTING MODE Field Setting Value(FSV) Table • Code 40✴✴ : User’s options for heating devices including internal backup heater and external boiler 401✴ : Space/DHW heating priority and control variables 402✴ : Backup/Booster heater priority and control variables 403✴...
  • Page 35 Remote Controller Setting Range : Code 10✴✴ Field Setting Value Main Menu & Sub Menu Function Description Default Step Unit Code Code ˚C Remote ✴✴11 Water Out Temp for Cooling ˚C ✴✴12 Controller ˚C ✴✴21 Setting Range Room Temp for Cooling ˚C ✴✴22 ˚C...
  • Page 36 Operating advanced function Operating advanced function FIELD SETTING MODE Water Law & Room Thermostat : Code 20✴✴ #2021/2031 Cooling WL #2022/2032 #2061/2071 Shift Value #2062/2072 ���������� Heating WL Floor FCU #2011 #2012 #2051 #2052 ������������������������������ Field Setting Value ��������������������������������������������������� Main Menu & Sub Menu Function Description Default...
  • Page 37 Water Law for Cooling • Outdoor air temperature range : Lower limit ➀ (#2051, Default 30˚C, Range : 25 ~ 35˚C), Upper limit ➁ (#2052, Default 40˚C, Range : 35 ~ 45˚C) - With this default settings, the water outlet temperature by cooling water law can be changed within the outdoor temperature range of 30 ~ 40˚C.
  • Page 38 Operating advanced function Operating advanced function FIELD SETTING MODE DHW Heating : Code 30✴✴ > T < T HP MAX HP MAX T(C) T(C) #3021 #3021 HP MAX HP MAX #3022 HP OFF #3023 HP OFF #3023 HP ON HP ON request operation #3024...
  • Page 39 DHW Application The FSV #3011 in the wired remote controller should be set to “1(Yes)” to use DHW function. Heat Pump Variables for Controlling DHW Tank • Maximum DHW tank temperature with R410A(refrigerant) heat pump operation : FSV #3021, Default 50˚C, Range : 45 ~ 55˚C. •...
  • Page 40 Operating advanced function Operating advanced function FIELD SETTING MODE DHW Heating : Code 30✴✴ request #3025 operation Booster operation #3032 #3033 BH OFF BH ON HP MAX #3022 HP OFF #3023 HP ON #3045 #3044 00.00 01.00 22.00 23.00 24.00 #3043 40_ Operating advanced function...
  • Page 41 - Scheduling : Day(#3042, Default “Friday”), starting time(#3043, Default “23:00”), target tank temp. (#3044, Default “70˚C”), duration(#3045, Default 10 min.) Disinfection function can be performed only with Samsung’s DHW tank installation. Urgent DHW by User’s Input (Hot Key of Wired Remote Controller) •...
  • Page 42 Operating advanced function Operating advanced function FIELD SETTING MODE Space Heating : Code 40✴✴ DHW by Booster Heater Only #3034 #4012 Field Setting Value Main Menu & Sub Menu Function Description Default Step Unit Code Code Heating Heat Pump Heating/DHW Priority 0(DHW) 1(Heating) ✴✴11...
  • Page 43 Backup Heater Variables for Space Heating • The FSV #4021 should be set to “1(On)”(Default) to use 2-stage electric backup heater in hydro unit as an additional heat source. • To compensate the lowered heat pump heating performance under very cold weather conditions, the FSV #4023 should be set to “1(On)”(Default).
  • Page 44 Operating advanced function Operating advanced function FIELD SETTING MODE Others : Code 50✴✴ Field Setting Value Main Menu & Sub Menu Function Description Default Step Unit Code Code Others Outgoing Mode Water Out Temp for ˚C ✴✴11 Cooling Code 50✴✴ Room Temp for Cooling ˚C ✴✴12...
  • Page 45: Appendix

    Appendix Appendix TEMPERATURE TABLE Available operation range Display Setting range Current Setting Control Mode Target temperature display method method Set View Default Available • Min : 5~18˚C Hydro or Leaving water 6~25˚C -50~94˚C Up/Down • Max : 18~25˚C Indoor unit Cooling •...
  • Page 46: Maintaining The Unit

    This maintenance should be carried out by SAMSUNG local technician. Besides keeping the remote controller clean by means of a soft damp cloth, no maintenance is required by the operator.
  • Page 47: Troubleshooting

    TROUBLESHOOTING If the unit has some problem to work properly, the LED on hydro unit will flash and some error codes will be displayed on the controller. The following table described the explanation of error codes on the LCD display. Thermistor Thermistor Thermistor...
  • Page 48 Appendix Appendix TROUBLESHOOTING Communication Display Explanation Abnormal communication B/W Wired remote controller & Hydro unit Communication tracking error B/W Wired remote controller & Hydro unit FRAM Read/Write Error(Wired remote controller data error) E601, E604 E654 • Wrong data transmit B/W micom & IC07(eeprom) 48_ Appendix...
  • Page 49 Water pump & Flow S/W Display Explanation WATER PUMP ERROR FLOW SWITCH ERROR Ref' In Ref' Out Water Out Water In E911 • Water pump OFF ( Flow S/W on ) E912 • Water pump ON ( Flow S/W off ) Water flow(>12LPM) •...
  • Page 50: Disposal Requirements

    Appendix Appendix DISPOSAL REQUIREMENTS • Dismantling of the unit, treatment of the refrigerant, of oil and of other parts must be done in accordance with relevant local and national legislation. • Your product is indicated with this symbol. This means that electrical and electronic products shall not be mixed with unsorted household waste.
  • Page 51 Memo Memo Appendix _51...