Air innovations MH-602 Instruction Manual

Air innovations MH-602 Instruction Manual

Ultrasonic

Advertisement

READ AND SAVE THESE INSTRUCTIONS
OWNER‟S MANUAL OF HUMIDIFIER MH-602
Instruction
Technical Data
Working Principle
Features

Correct Humidity Level

Function of MH-602
Security Guide
Explored Drawing
Operation Instruction
Trouble Shooting Guide
Maintenance
*Technical data
Model No: MH-602
Standard Output: 300ml/H
Water Tank Volume: 5.8 Liter
Noise Level: < 35 dB (A)
Rated voltage: 220-240V
Frequency: 50Hz
Rated Power input: 30W
N.W/G.W: 1.6kg/1.9kg
*Working Principle: Ultrasonic Humidifier use the ultrasonic high-frequency oscillator to break up
water into tiny water particles with the diameter of about 1-5um.The ventilation system blows out this
water into the dry air where they evaporate to give the required humidity. The clearly visible smooth
and even fog can be seen out of the unit.
*Features:
High efficient in humidification with large output.
Low energy consumption, save 85-90 percent of electricity of normal stream humidifier.
Long lifetime
Automatic control to humidity level, lack-water security protection.
*Correct Humidity Level:
What exactly is relative humidity: Relative humidity is the percentage of the actual water
vapor contains to the saturated water vapor contains under the same definite temperature and space.
We normally mark it with %RH, like 45%RH. Atomosphereic air always contains water vapor, the
percentage of which depends the meterological conditions. The higher the temperature is the more the
air keeps water vapor. Therefore, we use the concept of „relative humidity". When the cold air ins
heated up to the comfort temperature in winter, the relative percentage of the water vapor falls which
means the relative humidity drops. In order to keep a comfortable and health environment at home, we
need some artificial addition of water or water vapor to room air- that‟s air humidification.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MH-602 and is the answer not in the manual?

Questions and answers

Summary of Contents for Air innovations MH-602

  • Page 1: Correct Humidity Level

    READ AND SAVE THESE INSTRUCTIONS OWNER‟S MANUAL OF HUMIDIFIER MH-602 Instruction Technical Data Working Principle Features Correct Humidity Level Function of MH-602 Security Guide Explored Drawing Operation Instruction Trouble Shooting Guide Maintenance *Technical data Model No: MH-602 Standard Output: 300ml/H Water Tank Volume: 5.8 Liter...
  • Page 2  Ideal relative humidity levels under different situations. The most comfort RH for human being 45-65%RH Ideal RH for prophylactic and curative purpose: 40-55%RH Computer and telecom apparatuses: 45-60%RH Furniture and musical instrument: 40-60%RH Library art gallery and museums: 40-60%RH *Function of MH-505Ultrasonic Humidifier: To increase and to regulate relative humidity of the room air;...
  • Page 3: Product Overview

    *Operation Instruction First Operation, put unit under the room temperature for half of an hour before running (Especially when the outdoor temperature is lower than 5℃). It is recommended to use the unit under temperature of 5-40℃, relative humidity less than 80% Use clear water not over 40℃.
  • Page 4: Troubleshooting Guide

    corresponding power is from 17-19W (L), 19-23W (M), 23-27W (S) to 27-30W (H). 7. AUTO OFF: Settings from 1- 24 hours. 0 means cancelling the settings. 3 seconds after your settings, the timer function will be counted down to work by minutes and will display with current humidity by turns for 5 seconds if having set the humidity level.
  • Page 5: Maintenance

    Unit is on a unstable surface Move the unit to a stable flat surface Mist coming out around the There are apertures between the Dip the nozzle in water for a nozzle nozzle and water tank while and then fix it to the socket on water tank Water doesn‟t come down to Backup by filter...

Table of Contents

Save PDF