Maintenance; Troubleshooting - Lincat EB3 Installation, User & Servicing Instructions

Automatic fill water boilers
Table of Contents

Advertisement

IS09 ECN2087

Maintenance

Qualified personnel must carry out all maintenance work on the appliance.
Before commencing work on the appliance the electricity and water supplies must be isolated.
When replacing parts use only parts recommended by the manufacturer.
De-scale the appliance regularly. Severe scale deposits may block the drain valve. Prodding
through the tank-connector may puncture the drain hose.
Trouble-shooting
Fault
Will not fill
Continuous boil
Will not heat
Overflow
In the unlikely event of thermostat failure noticeable steam emissions will be observed from the
base of the appliance in the vicinity of the spillage tray. In such event the appliance should be
isolated from the main electrical and water supplies. A service engineer should be then contacted
to facilitate repair.
Probable Cause
Solenoid inlet blocked.
Severe scale build-up between upper and
lower level sensors and the tank body.
Water ingress between upper and lower
level sensor housings and tank body.
Circuit board relay RL1 locked open
circuit.
Circuit board relay RL2 locked open
circuit.
Severe scale build-up on thermostat
bulb. Thermostat fails to sense water
temperature.
Contactor locked on.
Thermostat failed closed circuit.
Loss of continuity on from circuit board
to lower sensor
Thermostat failed open circuit during
heating cycles.
Circuit board relay RL1 locked closed
circuit.
Solenoid locked open.
Clean solenoid filter
De-scale the appliance
Clean and dry sensor housings.
Replace washers as necessary.
Replace PCB
Replace PCB
De-scale the appliance
Replace contactor
Replace thermostat
Check red wire for continuity,
connection to lower sensor.
Replace circuit board if
necessary
Replace thermostat
Replace PCB
Ingress of foreign material.
Replace solenoid
13
Remedial Action

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EB3 and is the answer not in the manual?

Questions and answers

Mike ward
February 10, 2025

What descaling compound should I use for Lincat Boiler

1 comments:
Mr. Anderson
February 11, 2025

The Lincat EB3 boiler is supplied with a pack of de-scaling compound. Only parts recommended by the manufacturer should be used for maintenance, including descaling.

This answer is automatically generated

How to reset timer
April 22, 2025

LINCAT water boiler EB3FX How to reset timer

This manual is also suitable for:

Eb6Eb4Eb6t

Table of Contents

Save PDF