Lincat EB3 Installation, User & Servicing Instructions
Lincat EB3 Installation, User & Servicing Instructions

Lincat EB3 Installation, User & Servicing Instructions

Automatic fill water boilers

Advertisement

IS09 ECN2087
LINCAT
EB3, EB4 & EB6
Automatic Fill Water Boilers
Installation, User & Servicing Instructions
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EB3 and is the answer not in the manual?

Questions and answers

Mike ward
February 10, 2025

What descaling compound should I use for Lincat Boiler

1 comments:
Mr. Anderson
February 11, 2025

The Lincat EB3 boiler is supplied with a pack of de-scaling compound. Only parts recommended by the manufacturer should be used for maintenance, including descaling.

This answer is automatically generated

How to reset timer
April 22, 2025

LINCAT water boiler EB3FX How to reset timer

Subscribe to Our Youtube Channel

Summary of Contents for Lincat EB3

  • Page 1 IS09 ECN2087 LINCAT EB3, EB4 & EB6 Automatic Fill Water Boilers Installation, User & Servicing Instructions...
  • Page 2: Table Of Contents

    Troubleshooting Spare Parts 14 - 15 Tank assembly Base assembly Body assembly 16 - 17 Wiring and Circuit Diagrams EB3 Wiring diagram EB4 Wiring diagram EB6 Wiring diagram Circuit diagram Spare Parts List Replacing Parts 19 - 20 Thermostat Contactor...
  • Page 3: Introduction

    • Instruction booklet. • Guarantee card. The EB3 model is supplied with a 3 pin bonded plug and lead fitted with a 13Amp fuse as standard. The EB range of boilers is surface mounted and carries the option of being wall mounted. Wall fixing kits are an optional extra.
  • Page 4: Warnings And Precautions

    Do not place foreign objects in the tank of the appliance. Parts explosion, circuit and wiring diagrams are the sole property of Lincat and must not be reproduced without the consent of the manufacturer.
  • Page 5: Installation Preparation

    • All electrical work must comply with all relevant wiring regulations and carried out by a qualified electrician. • EB3 models require a 13Amp-supply socket. • EB4 models require a 20Amp supply. • EB6 models require a 30Amp single or multi-phase supply.
  • Page 6: Installation

    Instruction to the owner of the appliance must be given on how to isolate the appliance in case of emergency. The work surface must have a minimum depth of 600mm. The spillage tray must be fitted with the appliance EB6 dimensional details EB4 dimensional details EB3 dimensional details...
  • Page 7: Wall Bracket Installation

    IS09 ECN2087 Wall Bracket Installation Where the appliance is to be mounted to a wall ensure the wall is constructed of a suitable material to sustain the working weight of the boiler. • To fit the wall bracket make a centre mark on the wall at approximately 1400mm from the floor.
  • Page 8: Overflow And Drainage

    All appliances must be earthed. The EB3 model is supplied with a 3 pin bonded plug and lead fitted with a 13Amp fuse as standard. The plug is to be connected to a suitable mains socket. The wiring markings are as...
  • Page 9: Commissioning The Appliance

    • Upon the water reaching the lower element sensor the solenoid will close and the element(s) will begin to heat the water. • Approximate heating times for the initial fill is: - EB3 – 12 minutes EB4 – 9 minutes EB6 – 9 minutes •...
  • Page 10: User Instructions

    IS09 ECN2087 User Instructions • Retain these instructions for future reference. • Ensure that the spillage tray is in the correct position before operating the appliance. • Care should be taken to avoid injury whilst operating the appliance at the water temperature is maintained at approximately 98 •...
  • Page 11: De-Scaling The Appliance

    IS09 ECN2087 De-scaling the Appliance It is recommended that the appliance be de-scaled regularly. Excessive scale deposits may become difficult to remove with some de-scaling products. • To de-scale the appliance, isolate the appliance from the water and electricity supply. •...
  • Page 12: Technical Specifications

    IS09 ECN2087 Technical Specifications Dimensions Model Height Width Depth 600mm 275mm 315mm 600mm 345mm 315mm 600mm 440mm 315mm EB6/T 600mm 440mm 315mm Weight Model Working 13.5kg 30.5kg 15kg 34.5kg 18.5kg 46kg EB6/T 18.5kg 46kg Capacities Model Working Total 10 litres 16 litres 13litres 20.5 litres...
  • Page 13: Maintenance

    IS09 ECN2087 Maintenance Qualified personnel must carry out all maintenance work on the appliance. Before commencing work on the appliance the electricity and water supplies must be isolated. When replacing parts use only parts recommended by the manufacturer. De-scale the appliance regularly. Severe scale deposits may block the drain valve. Prodding through the tank-connector may puncture the drain hose.
  • Page 14: Spare Parts

    IS09 ECN2087 Spare Parts Before removing and replacing any part on the appliance the appliance must be isolated from the water and electricity supply. Replacement of parts must be parts approved by the manufacturer. Some parts are not shown in the parts explosion diagrams, as they are non-serviceable. Tank Assembly Note: The tank lid is inclusive with the tank when the tank is ordered as a spare part.
  • Page 15: Base Assembly

    IS09 ECN2087 Base Assembly Body Assembly The body manufactured as a complete part, panels are not available separately. The lid bezel is fitted to the lid; clips are required in the fitting. The tap bezel is screwed to the bodywork. The neon lens and neon housing are serviceable parts.
  • Page 16: Wiring And Circuit Diagrams

    IS09 ECN2087 Wiring and Circuit Diagrams EB3 Wiring Diagram EB4 Wiring Diagram NEON...
  • Page 17: Eb6 Wiring Diagram

    For multi-phase wiring of the EB6, remove the link wire at L1 & L2. Circuit Diagram The circuit diagram above is essentially for the EB3 as the element is powered via the thermostat. For the EB4 and EB6 switching of the contactor that powers the element(s) is made via the...
  • Page 18: Spare Parts List

    Badge BE16 Tap bezel BE17 Neon bezel CO111 Contactor CO112 Contactor DV01 Drain valve EL178 Element 3000W 240V EB3 & EB6 EL179 Element 4500W 240V FE01 Feet LA168 Lid assembly LA169 Lid assembly LA170 Lid assembly LE18 Lower level sensor...
  • Page 19: Replacing Parts

    IS09 ECN2087 Replacing Parts Before removing and replacing any part on the appliance the appliance must be isolated from the water and electricity supply. Replacement of parts must be parts approved by the manufacturer. Thermostat • Remove the outer lid. •...
  • Page 20: Neon

    IS09 ECN2087 Neon • Remove the outer lid. • Remove the retaining screws from the back panel and slide the back panel vertically upward. • Remove the retaining screws from the access panel. • Loosen the tank-retaining bracket and ease that tank backward to gain access to the neon housing.
  • Page 21: Service

    If possible please quote the product code of the part number you require. GUARANTEE STATEMENT Lincat Ltd guarantees its equipment to be free from defects in materials and workmanship for a period of 1 (one) year commencing from the date of purchase from the dealer, by the original owner.