4.1.7 Operating Modes
Preparation
Heating up
Pre-heating
Ignition
Heating
Constant burn
Cleaning
Shutdown wait
Shutdown wait 1
Shutdown wait 2
Fault
Burner Off
Fröling Heizkessel- und Behälterbau Ges.m.b.H, Industriestrasse 12, A-4710 Grieskirchen
Tel +43 (0) 7248 606-0 Fax +43 (0) 7248 606-600 info@froeling.com www.froeling.com
The boiler is ventilated, the sealing slider is opened and the Lambda
probe is heated.
The combustion chamber is filled with pellets.
The fan-assisted ignition switches on and the pellets are preheated until
a bed of embers is formed. For this period loading is deactivated.
The pellets are ignited with the fan-assisted ignition. The flame is
distributed around the whole combustion chamber. The control of the
loading unit is defined as "Ignition" in the parameter menu.
The Lambdatronic controls combustion according to the boiler set-points.
The boiler has no power consumption. The ID fan and the loading unit
are deactivated.
The Lambdatronic carries out the cleaning program (duration approx. 3
min).
When the boiler is interrupted during the heating up procedures (heating
up, pre-heating, ignition), it waits for a specified period of time until the
next start attempt.
The ID fan runs to burn the remaining pellets.
The loading unit is deactivated.
The system is still ventilated by chimney draught. The loading unit is
deactivated.
CAUTION-Fault persists!
Procedure see Chapter 6-Troubleshooting
The Lambdatronic controls the connected heating components. All parts
of the boiler are deactivated.