Digital Communicator Reset Sequence: 096060; Control Panel Factory Default Reset - jablotron JA-63 PROFI Installation Manual

Hide thumbs Also See for JA-63 PROFI:
Table of Contents

Advertisement

Digital communicator reset
14.6
By entering this code the factory default settings of all parameters are restored in the digital dialer. All phone numbers,
reporting codes, account codes etc. are erased. This reset doesn't effect the voice dialer's settings. The reset sequence
is:
0 9 6060
Note: All communicator settings are stored in non-volatile memory and remain unchanged even after switching off the power supply.

15 Control panel factory default reset

If you forget the control panel codes or you have a control panel which is currently not under factory default settings,
perform the following:
disconnect the AC power and back up battery in the control panel and wait for 10 seconds.
connect (short) the RESET pins on the main board
leave the control panel cover open
reconnect back up battery and the AC power
within 1 minute disconnect the RESET jumper
reset is confirmed with a "P" (panel is in programming mode)
Note: this procedure resets the factory default settings (see part 10). The Master code will be 1234, Service code 6060
and all user codes, wireless detectors & controllers will be forgotten. All telephone numbers for voice message and Pager
dialing will be erased in the communicator. The reset will not erase event memory and information about the reset will be
recorded there. The RESET pins can also be used to enroll a JA-60F wireless keypad (see 10.1).
Warning: if the Master code is forgotten when reset is disabled (with sequence 280), the control panel reset will be
possible only by the manufacturer.
JA-63 „PROFI" Alarm System
- 24 -
sequence: 096060
MGK51404

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the JA-63 PROFI and is the answer not in the manual?

Questions and answers

Table of Contents