MEMO:
When you replace the HDD without uninstalling MEAP applications, make sure to reinstall the previously installed applications. Unless reinstalling them, MEAP
counter will not be released and the message "The number of applications that can be installed has exceeded the limit. Try to install this application after uninstalling
other applications." is displayed so that the installation of new applications may not be accepted.
If you want to install new applications in this case, once reinstall the applications installed before formatting and uninstall unnecessary applications.
11.1.28 MEAP Safe Mode
iR3225 / iR3225N / iR3235 / iR3235N / iR3245 / iR3245N
Use safe mode if you need to start up the system without worrying about extra applications. It will start up only those system software files (including SMS) that
normally start up as default files while preventing MEAP applications and the like from starting up.
When you have made changes and turned off and then on the device, the control panel will indicate 'MPSF' in its lower right corner. The MEAP applications that
may have been active before you shut down the equipment will not start up on their own. Make use of safe mode when restoring the system software as when MEAP
applications or services cause a fault as the result of a conflict or wrong sequence of registration/use. You can access to SMS in this condition so that you can take
necessary measures, for example, you can stop application that may cause the trouble.
If default authentication has been selected, the mode of authentication remains valid; otherwise, the message "The login service must be set again with SMS" ap-
pears. Change the login service as necessary.
Starting in Safe Mode
1) Start the device in service mode: click [Ad Func] key, press 2 and 8 buttons at the same time, and then click [Ad Func] key once again so that the service mode
screen appears.
2) Press [COPIER] button.
3) Press [OPTION] button.
4) Press [USER].
5) Press the right-arrow button.
6) Press [MEAPSAFE].
7) Press the 1 key on the control panel keypad to change the setting to '1'; then, click [OK] button.
8) Check that the notation 'MPSF' has appeared in the lower right corner of the screen; then, turn off and then on the main power.
F-11-59
F-11-60
Chapter 11
0019-9229
11-41
Need help?
Do you have a question about the iR3245 Series and is the answer not in the manual?
Questions and answers